Technical Overview

The Festo CPX-AP-I-4DI4DO-M8-3P combines four PNP digital inputs and four PNP digital outputs, each group using four three-pin A-coded M8 sockets. IEC 61131-2 type 3 inputs support compatible two- and three-wire sensors, while type 0.5 outputs provide up to 0.5 A per channel. Input debounce options are 0.1, 3, 10 and 20 ms; output delay with ohmic loads is below 200 µs in both switching directions. M8 AP system connections exchange one input byte and one output byte. The 129 g module uses nominal 24 V DC electronics/sensor and load supplies, with IP65/IP67 protection and −20 to 60 °C ambient operation.

CPX-AP-I module with four PNP inputs, four 0.5 A PNP outputs, three-pin M8 connections and IP65/IP67 protection.

Key Features

  • Four PNP digital inputs to IEC 61131-2 type 3
  • Four PNP digital outputs to IEC 61131-2 type 0.5
  • Four three-pin A-coded M8 input sockets and four matching output sockets
  • Maximum 0.5 A per output channel with individual electronic short-circuit protection
  • Input debounce options 0.1, 3, 10 and 20 ms
  • Output delay below 200 µs for both transitions with ohmic loads
  • One-byte input and one-byte output address volumes over AP communication
  • Module, load-power and channel LEDs with internal supply/output fault diagnostics
  • Nominal 24 V DC supplies; maximum 2 × 4 A power feed with external fusing
  • 129 g product weight; IP65/IP67 protection and −20 to 60 °C ambient range

Connect four PNP sensors and four 0.5 A loads to one AP module using three-pin M8 interfaces.

Technical Specification Matrix

ParameterValue
Type of mountingOn DIN rail via accessories; With through-hole
Physical Weight (kg)0.129
Ambient temperature-20 °C...60 °C
Storage temperature-40 °C...70 °C
Relative air humidity5 - 95%; Non-condensing
Degree of protectionIP65; IP67
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Overvoltage categoryII
Max. cable length30 m outputs; 30 m inputs; 50 m system communication
Note on max. cable lengthPower supply according to nominal voltage
LABS (PWIS) conformityVDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14Element installed statically, no meaningful evaluation possible according; to ISO 14644-1
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
ApprovalRCM; c UL us - Listed (Oil)
Note on materialsRoHS compliant
Material o-ringFluoro rubber
Diagnostics via LEDDiagnostics per module; Load power supply; Status per channel
Diagnostics per internal communicationSwitch-off load supply; Short-circuit/overload in output signal; Short circuit/overload in sensor supply; Electronics/sensors overvoltage; Load overvoltage; Electronics/sensors undervoltage; Load undervoltage
Max. address volume, inputs1 Byte
Max. address volume, outputs1 Byte
Number of outputs4
Communication interface, functionSystem communication XF10 IN / XF20 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, protocolAP
Communication interface, screenedYes
Power supply, functionIncoming electronics/sensors and load
Power supply, connection typePlug
power supply, connection systemM8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires4
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Note regarding operating voltageSELV/PELV fixed power supplies required; Note the voltage drop
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load±25%
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors±25%
Max. power supply2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 35 mA
Intrinsic current consumption at nominal operating voltage loadTypically 10 mA
Power failure bridging10 ms
Reverse polarity protectionYes
Electrical connection input, functionDigital input
Electrical connection input, connection type4x socket
Electrical connection input, connector systemM8x1, A-coded to EN 61076-2-104
Electrical connection input, number of connections/cores3
Number of inputs4
Characteristic for inputsTo IEC 61131-2, type 3
Switching levelSignal 0: <= 5 V; Signal 1: ≥ 11 V
Switching logic for inputsPNP (positive switching); 2-wire sensors to IEC 61131-2; 3-wire sensors to IEC 61131-2
Input debounce time0.1 ms; 3 ms; 10 ms; 20 ms
Fuse protection of inputs (short circuit)Internal electronic fuse per module
Max. residual current of inputs per module1.8 A
Electrical isolation of inputs between channelsNo
Electrical isolation of inputs between channel – internal communicationYes
Electrical connection output, functionDigital output
Electrical connection output, connection type4x socket
Electrical connection output, connector systemM8x1, A-coded to EN 61076-2-104
Electrical connection output, number of connections/cores3
Characteristic for outputsTo IEC 61131-2, type 0.5
Switching logic for outputsPNP (positive switching)
Fuse protection of outputs (short circuit)Internal electronic fuse per channel
Output delay with ohmic loadSignal change 0->1: < 200 µs; Signal change 1->0: < 200 µs
Electrical isolation of outputs between channelsNo
Electrical isolation of outputs between channel - internal communicationYes
Max. power supply per channel0.5 A
Dimensions L x W x H (cm)17 x 3 x 3.5

Industrial Applications

1. Distributed Position-Sensor Acquisition

A machine station needs local feedback from several compatible PNP position sensors while its AP system carries the information to the controller. This module provides four digital inputs through separate three-pin M8 sockets and uses one byte of input address space. Two- and three-wire sensor support, selectable debounce and channel LEDs define the documented acquisition and local indication functions.

Problem Solved

The module gathers multiple position-switch signals at a local AP connection point, providing process inputs and channel indication for coordinating the station's ordinary machine sequence.

Four PNP inputs M8 connections Selectable debounce

2. Local Switching of Solenoid or Indicator Loads

A station needs controller-commanded outputs for compatible low-current solenoid or indicator loads near the mechanism. Four PNP outputs provide up to 0.5 A per channel through three-pin M8 sockets. Each output has an electronic short-circuit fuse, while the specified below 200 µs delay applies to ohmic loads and does not define the response of an inductive device.

Problem Solved

Local outputs translate AP control data into positive-switching load commands, providing individually protected connections for compatible station devices within the documented per-channel current rating.

Four PNP outputs 0.5 A per channel Per-channel electronic fuse

3. Diagnosing Sensor and Output Wiring Faults

A station loses sensor feedback or a commanded load and maintenance needs to distinguish a process condition from an electrical fault. Internal AP diagnostics identify sensor-supply shorts, output-signal short circuits or overloads, and electronics or load-voltage errors. Module, load-power and channel LEDs provide local information, while separate input-module and output-channel electronic fuses define the documented protection arrangement.

Problem Solved

Separate sensor, output and supply diagnostics identify the electrical fault category, helping maintenance direct troubleshooting toward the relevant field wiring or power circuit.

Sensor-supply diagnostics Electronic fuse Channel LEDs