| Protocol | CODESYS Level 2; EasyIP; Modbus TCP; TCP/IP |
| Physical Weight (kg) | 0.155 |
| Ambient temperature | -5 °C...50 °C |
| Storage temperature | -20 °C...70 °C |
| Relative air humidity | 95%; Non-condensing |
| Degree of protection | IP65; IP67 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| Note on materials | RoHS compliant |
| Material housing | Reinforced PA; Makrolon® |
| LED display, product-specific | ERR: PLC run-time error; M: Modify/force enabled; PL: Load supply; PS: Electronics supply, sensor supply; RUN: PLC status; SF: System errors; STOP: PLC status |
| LED display, bus-specific | TP: Link/Traffic |
| Device-specific diagnostics | Channel-oriented and module-oriented diagnostics; Undervoltage/short circuit of modules; Diagnostics memory |
| Operator controls | DIL switch for CAN termination; Rotary switch for RUN/STOP |
| IP address setting | DHCP; Via CODESYS; Via MMI |
| Fieldbus interface | CAN bus |
| Field bus interface, connection system | Plug; Sub-D; 9-pin |
| Field bus interface, electrical isolation | Yes |
| Field bus interface, transmission rate | 125, 250, 500, 800, 1000 kbit/s; Can be set using software |
| Ethernet interface | RJ45 (socket, 8-pin) |
| Ethernet, number | 1 |
| Ethernet, supported protocols | TCP/IP, EasyIP, Modbus TCP |
| Ethernet, plug connector | RJ45; Bushing; 8-pin |
| Ethernet, data transmission rate | 10/100 Mbit/s |
| Parameterisation | CODESYS V2.3 |
| Configuration support | CODESYS V2.3 |
| Additional functions | Diagnostic functions; Motion functions for electric drives |
| CPU data | 32 MB Flash; 32 MB RAM; 400 MHz processor |
| Control-Interface | CAN bus |
| Nominal operating voltage DC | 24 V |
| Nominal DC operating voltage, load voltage | Without pneumatics: 18 ... 30V; 24 V; With pneumatics type midi/maxi: 21.6 ... 26.4 V; With pneumatics type CPA: 20.4 ... 26.4 V; With pneumatics type MPA: 18 ... 30 V |
| Intern power consumption nominal operating voltage | Typ. 85 mA |
| Power failure bridging | 10 ms |
| Programming, operating language | DE, EN |
| Programming language | To IEC 61131-3; LDR; IL; ST; FBD; AS; Additionally CFC |
| Programming, support for file handling | Yes |
| Programming software | CODESYS provided by Festo V2.3 |
| Program memory | 4 MB user program |
| Processing time | Approx. 200 µs/1 k instruction |
| Function modules | Read CPX module diagnostics; CPX diagnostic status; Copy CPX diagnostic trace; And others |
| Flag | 30 kB remanent data; 8 MB global data memory; CODESYS variable concept |
| Total number of axes | 31 |
| Dimensions L x W x H (cm) | 10.7 x 5 x 5.5 |