Sale!

Festo 1544198 CTEU-CC CC-Link Bus Node, 24 V DC

Original price was: USD 339.82.Current price is: USD 291.98.

CC-Link bus node with isolated nine-pin Sub-D interface, 16-byte input/output address limits, I-Port diagnostics and 18–30 V DC power range.

Festo Remote I/O and Network Interface Components

Festo CTEU-CC CC-Link Bus Node

BrandFesto
Model IdentifierCTEU-CC
Official Part Number1544198

Technical Overview

The Festo CTEU-CC connects a compatible valve terminal or I-Port device to a CC-Link master through an electrically isolated nine-pin Sub-D interface. Its listed transmission range is 156–10000 kbit/s, with maximum input and output address volumes of 16 bytes each. DIL switches support local settings, while system status can be mapped through process data. Communication errors, undervoltage and system diagnostics are accompanied by bus, supply and I-Port LEDs. The 90 g PA-housed node operates from 18–30 V DC through a five-pin A-coded M12 power connector. IP65/IP67 protection applies in the mounted state with unused connections sealed; optional open-style screw-terminal connection is IP20.

CC-Link bus node with isolated nine-pin Sub-D interface, I-Port system diagnostics, 18–30 V DC supply and 90 g product weight.

Key Features

  • CC-Link serial fieldbus interface
  • Electrically isolated nine-pin Sub-D socket
  • Listed fieldbus transmission range 156–10000 kbit/s
  • Maximum input and output address volumes of 16 bytes each
  • Internal cycle time of 1 ms per user-data byte
  • DIL controls and configurable diagnostic, idle and fail-safe response parameters
  • System status can be mapped through process data
  • Supply, I-Port and bus LEDs with communication and undervoltage diagnostics
  • Five-pin A-coded M12 power input; 18–30 V DC, nominal 24 V DC and maximum 4 A supply
  • 90 g product weight; IP65/IP67 when mounted and sealed, with optional IP20 open-style bus connection

Bring compatible I-Port equipment onto CC-Link with local bus indication and system-status mapping through process data.

Technical Specification Matrix

ParameterValue
ProtocolCC-LINK®
Mounting grid pitch40 mm
Type of mountingOn electrical interface; On electrical connection block
Physical Weight (kg)0.09
Ambient temperature0 °C...50 °C
Storage temperature-20 °C...70 °C
Degree of protectionIP65; IP67
Note on degree of protectionIn mounted state; Unused connections sealed
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
KC markKC-EMV
ApprovalRCM; c UL us - Listed (Oil)
Note on materialsRoHS compliant
Material housingPA
LED display, product-specificPS: Operating voltage for electronics and load supply; X1: System status of module at I-Port 1; X2: System status of module at I-Port 2
LED display, bus-specificErr: Data transmission error; Run: Bus active
DiagnosisCommunication error; System diagnostics; Undervoltage
Operator controlsDIL switch
Note on fieldbus interfaceOptional accessory connection: open-style five-pin screw terminal, IP20
Fieldbus interfaceSerial interface
Field bus, protocolCC-LINK®
Field bus, connection typeSocket
Field bus, connection systemSub-D
Field bus, connection pattern9
Field bus interface, electrical isolationYes
Field bus interface, transmission rate156 - 10000 kbit/s
Max. address volume, inputs16 Byte
Max. address volume, outputs16 Byte
ParameterisationActivating diagnostics; Fail-safe and idle response
Internal cycle time1 ms per 1 byte of user data
Additional functionsSystem status can be mapped using process data
Power supply, functionElectronics and load
Power supply, connection typePlug
power supply, connection systemM12x1, A-coded according to EN 61076-2-101
Power supply, number of pins/wires5
Operational voltage range DC18 V...30 V
Nominal operating voltage DC24 V
Max. power supply4 A
Intern power consumption nominal operating voltageTyp. 70 mA
Dimensions L x W x H (cm)9.1 x 4 x 5

Industrial Applications

1. CC-Link Integration of a Valve Terminal

A machine with a CC-Link master needs to command a compatible Festo valve terminal through its I-Port interface. The CTEU-CC supplies the fieldbus connection using a nine-pin Sub-D socket and an electrically isolated serial interface. Its maximum 16-byte input and output address volumes define the listed capacity for configuring the selected terminal's process-data exchange.

Problem Solved

The bus node translates between the CC-Link connection and compatible I-Port equipment, providing a documented communication path for valve commands and the terminal's associated process information.

CC-Link I-Port equipment Isolated Sub-D interface

2. Station-status Visibility in Process Data

A controller needs a station-status indication alongside the ordinary commands exchanged with its pneumatic equipment. The bus node supports mapping system status through process data and provides diagnostics for communication errors, undervoltage and system conditions. Local PS, X1 and X2 indicators show supply and I-Port module states, allowing the same station to expose information at the machine and to its controller.

Problem Solved

System-status mapping adds a controller-visible condition to the process-data exchange, while local indicators help relate that condition to the supply and connected I-Port equipment.

System-status mapping I-Port LEDs Undervoltage diagnostics

3. Configured Response to Bus Idle or Communication Loss

A machine sequence needs its connected equipment's behaviour defined when the network is idle or a communication problem occurs. The CTEU-CC lists parameterisation for fail-safe and idle response together with activation of diagnostics. DIL switches provide the local operating controls, while bus error and run indicators expose the communication condition during commissioning and ordinary fault investigation.

Problem Solved

Configurable idle and communication-loss responses give the station a defined operational parameter set for those network conditions, with diagnostic indication supporting verification during commissioning.

Idle response parameters DIL controls Bus diagnostics
Select your currency