SICK 1036791 DFS60 10,000-pulse TTL/HTL Incremental Encoder

SICK 1036791 DFS60 10,000-pulse TTL/HTL Incremental Encoder

USD 646.36

DFS60B-BDPL10000 offers 10,000 pulses per revolution, programmable TTL/HTL signals, a 10 mm blind hollow shaft with front clamp and 3 m universal cable.

SKU: SICK-1036791 Category:
SICK Encoders

SICK DFS60B-BDPL10000 Incremental Encoder

BrandSICK
Model IdentifierDFS60B-BDPL10000
Official Part Number1036791

Technical Overview

The SICK DFS60B-BDPL10000 is an incremental encoder with 10,000 pulses per revolution, six TTL/HTL signal channels and TTL output level as its factory setting. Its 10 mm blind hollow shaft uses a front clamp, while a 3 m eight-wire universal cable can be routed radially or axially. The encoder operates from 4.5–32 V, provides output frequency up to 600 kHz and permits mechanical speed up to 6,000 rpm; the usable pulse/speed combination must also respect the frequency limit and speed-related heating. The stainless-steel shaft, aluminum flange and die-cast aluminum housing provide IP67 at the housing/cable connection and IP65 at the shaft side.

10,000-pulse incremental encoder with programmable TTL/HTL outputs, 10 mm blind hollow shaft, front clamp, 3 m universal cable and 4.5–32 V supply.

Key Features

  • 10,000 pulses per revolution; incremental rotary encoding
  • Six TTL/HTL signal channels; programmable/configurable; factory output level TTL
  • A, B and Z signals with complementary channels
  • 10 mm blind hollow shaft with front clamp
  • 3 m eight-wire universal cable; radial or axial routing
  • 4.5–32 V supply; ≤0.7 W without load; load current ≤30 mA
  • Output frequency ≤600 kHz; mechanical speed ≤6,000 rpm with frequency and heating limits also applied
  • Configurable electrical zero-pulse widths 90° / 180° / 270°; mechanical width 1–359°
  • IP67 housing/cable connection and IP65 shaft side
  • Stationary cable: −40 to +100 °C; flexible cable: −30 to +100 °C; allow speed-related self-heating

Provide incremental shaft-motion signals to compatible external counting or drive electronics, matching output level and pulse rate to the receiving input.

Technical Specification Matrix

ParameterValue
Functional principleIncremental rotary encoding
Pulses per revolution10,000; observe pulse-count/speed and output-frequency limits
Measuring step90° electrical / pulses per revolution
Non-binary step deviation±0.01°
Error limits±0.05°
Output interfaceTTL / HTL; programmable/configurable; factory output level TTL
Signal channelsSix: A, A̅, B, B̅, Z, Z̅
Output frequency≤600 kHz
Load current≤30 mA
Power supply4.5–32 V
Power consumption≤0.7 W without load
Initialization time32 ms; 30 ms with mechanical zero-pulse width
Reference signalOne; 90° electrical, logically gated with A and B
Zero-pulse width configurationElectrical: 90°, 180° or 270° relative to a pulse period; mechanical: 1–359° relative to one shaft revolution
Reverse-polarity protectionYes
Output short-circuit protectionMaximum 30 s: TTL programmed with supply ≥5.5 V permits short to another channel or GND; HTL or TTL with supply <5.5 V permits short to another channel, supply or GND
Connection3 m eight-wire universal cable; radial or axial routing without bends at the cable connection
Wire assignmentWH=A; BN=A̅; PK=B; BK=B̅; VT=Z; YE=Z̅; BU=GND; RD=+Us
Screen connectionConnected to housing at encoder side; connected to ground at control side
Cable drawing dataDiameter 5.6 ±0.2 mm; bending radius 30 mm
Mechanical designBlind hollow shaft with front clamp
Shaft diameter10 mm
Shaft materialStainless steel
Flange materialAluminum
Housing materialAluminum die-cast
Starting torque0.8 Ncm at +20 °C
Operating torque0.6 Ncm at +20 °C
Permissible static movement±0.3 mm radial; ±0.5 mm axial
Permissible dynamic movement±0.1 mm radial; ±0.2 mm axial
Operating speedMechanical limit ≤6,000 rpm; allow 3.3 K self-heating per 1,000 rpm and also respect output-frequency/pulse-count limits
Rotor inertia40 gcm²
Bearing lifetime3.6 × 10¹⁰ revolutions
Angular acceleration≤500,000 rad/s²
IP ratingIP67 housing side and cable connection; IP65 shaft side; IEC 60529
Relative humidity90%; condensation not permitted
Operating temperature−40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable; allow speed-related self-heating
Storage temperature−40 to +100 °C without package
Shock resistance70 g, 6 ms; EN 60068-2-27
Vibration resistance30 g, 10–2,000 Hz; EN 60068-2-6
EMCEN 61000-6-2 and EN 61000-6-3
MTTFD300 years, EN ISO 13849-1; standard product, not a safety component

Industrial Applications

1. Providing shaft-speed feedback to external control

A driven shaft can couple directly to the correctly fitted blind hollow shaft and front clamp. External counting electronics determine speed from the incremental pulses using the configured TTL or HTL level. Commissioning checks pulse frequency at maximum application speed against both the 600 kHz output limit and receiver capability, while allowing for cable routing, mechanical alignment and speed-related self-heating.

Problem Solved

Incremental motion pulses help external control electronics calculate monitored shaft speed, provided the selected output level and pulse rate match the receiver and the installation respects mechanical limits.

Shaft speed TTL/HTL signals Pulse frequency

2. Measuring travel from a mechanically linked roller

A measuring roller can rotate the encoder through a suitable 10 mm shaft connection so external counting logic relates pulses to material travel. Setup establishes the effective roller circumference and transmission relationship, matches the output level to the counter and checks slip. The application also verifies pulse rate, mounting movement and actual measurement uncertainty instead of assuming encoder resolution alone defines travel accuracy.

Problem Solved

A repeated pulse reference helps external counting logic estimate material travel from a mechanically linked roller, with commissioning establishing the motion relationship and checking the effects of slip.

Roller travel Incremental counting Motion relationship

3. Relating a cyclic mechanism to its index signal

A cyclic mechanism can use the encoder’s A and B channels for incremental motion and its Z reference signal to identify a recurring shaft reference. Compatible external logic evaluates the channels using the selected zero-pulse width. Commissioning checks the reference position, electrical signal level and receiver timing, and establishes any application-specific homing procedure needed for position tracking after startup.

Problem Solved

A recurring index reference helps external logic relate incremental counts to a chosen cycle position, supporting repeatable process referencing when the controller implements the required initialization procedure.

Cycle reference Index pulse External position logic
Select your currency