1. Pallet Arrival at a Conveyor Workstation
A conveyor workstation needs a mechanical stop for an arriving workpiece carrier. The roller-equipped, non-rotating rod presents the stopping interface, while the cylinder’s 30 mm stroke provides the withdrawal travel. The 5000 N impact rating applies to force on the extended rod; permissible carrier mass depends on speed, buffering and the manufacturer’s mounting conditions, rather than that force alone.
Problem Solved
The raised roller rod provides a defined stopping interface and retracts to release the carrier, supporting controlled workstation entry within the documented impact, mounting and conveyor-loading conditions.
Roller piston rod
30 mm stroke
5000 N impact rating
2. Release from a Continuing Conveyor Load
A conveyor may continue applying a lateral friction load after a carrier has stopped. The roller rod and single-acting pulling operation provide the mechanism for withdrawing the stop, with lateral switching force specified separately from impact force. The current exact-part datasheet lists 1250 N permissible lateral force during switching; the catalog explains that this condition is evaluated after impact and depends on available pneumatic pressure.
Problem Solved
Separating the withdrawal load from the arrival impact supports a stop-release mechanism based on the relevant lateral switching condition, while the roller-equipped pulling rod supplies the release movement.
Single-acting pulling
Roller rod
Lateral switching load
3. Position-Confirmed Transfer-Line Sequencing
A transfer line needs to coordinate a carrier-release command with the stopper’s actual piston position. This cylinder supports proximity-switch detection and uses an anti-rotation rod design to maintain the roller’s orientation. The controller can use compatible switch inputs to distinguish extended and withdrawn conditions, while the documented 5 Hz maximum cycle frequency defines a component limit for sequence planning.
Problem Solved
Position-detection capability provides feedback from the cylinder movement, allowing the transfer sequence to coordinate release with the observed piston position instead of relying only on a timed command.
Proximity-switch detection
Anti-rotation rod
5 Hz maximum