DT50-N1114 measures0.2–10 m on90% remission with one NPN output,one 0–10 V analog signal,16-bit output resolution and IP65 protection.

SKU SICK-1047582 Category
Laser Distance Sensors - SICK Dx50

SICK DT50-N1114 NPN Analog Laser Distance Sensor

BrandSICK
Model IdentifierDT50-N1114
Official Part Number1047582

Technical Overview

The SICK DT50-N1114 measures distance to natural objects using a class 2 red time-of-flight laser. Range is 200–10,000 mm at 90% remission, 200–6,500 mm at 18% remission and 200–4,000 mm at 6% remission. One NPN switching output and one 0–10 V analog output support external machine control. The analog signal has 16-bit output resolution, with teach-in, scaling and inversion. Fast/slow averaging gives specified 20/30 ms lateral-entry response; output time is ≥4 ms for continuous distance change. A multifunction input supports laser-off or external teach. The IP65 zinc-diecast sensor includes an LC display, two LEDs and an M12 five-pin male connector, with warm-up up to fifteen minutes.

Target-dependent200–10,000 mm distance sensor with one NPN output,one 0–10 V analog output,16-bit output resolution and M12 five-pin connection.

Key Features

  • 200–10,000 mm at90% remission;200–6,500 mm at18%;200–4,000 mm at6%
  • 658 nm class2 red laser;typical15 ×15 mm spot at10 m
  • One NPN digital output;maximum current≤100 mA
  • One 0–10 V analog output;load≥5,000 Ω;16-bit output resolution
  • Teach-in,scaling and inversion of analog/digital outputs
  • Fast/slow averaging;20/30 ms lateral-entry response
  • Output time≥4 ms for continuous distance change
  • Distance-to-object switching;10–1,000 mm hysteresis;laser-off/teach input
  • LC display,two LEDs and M12 five-pin male connector
  • IP65 zinc-diecast housing;−30 to+65 °C operation;warm-up≤15 min

Send a distance-related analog signal and a taught switching condition to external machine control,with target remission and electrical loads checked for the installation.

Technical Specification Matrix

ParameterValue
Functional principleTime-of-flight laser distance evaluation
TargetNatural objects
Measuring range200–10,000 mm at90% remission;200–6,500 mm at18%;200–4,000 mm at6%
Repeatability≥2.5 mm;1σ;6–90% remission;depends on fast/slow averaging
AveragingFast or slow
Response time20/30 ms,depending on fast/slow averaging;lateral object entry
Light sourceVisible red laser;658 nm
Laser class2;IEC60825-1:2014 and EN60825-1:2014
Laser pulse figuresMaximum output180 mW;pulse5 ns;duty cycle1/200
Laser handlingDo not intentionally look into the beam or point it at eyes
Typical light spot15 ×15 mm at10 m
Average laser service life100,000 h at25 °C
Digital outputs1 ×NPN;maximum output current≤100 mA;short-circuit protected
Switching modesDistance to object(DtO)
Output adjustmentTeach-in,scaling and inversion of digital and analog outputs
Hysteresis10–1,000 mm
Multifunction inputLaser off,external teach or deactivated;input response≤15 ms
Other functionsSwitch-off display,reset,lock user interface
Power supply>15 V to30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A
Power consumption≤2.1 W without load
Supply ripple≤5 Vpp;must remain within supply limits
Initialization time≤250 ms
Warm-up time≤15 min
Indicators and displayLC display and2LEDs
ConnectionM12 five-pin male connector
Pin assignment1BN=L+;3BU=M;4BK=Q digital;2WH=QA analog;5GY=MF
Housing materialZinc diecast
Window materialPMMA plastic
IP ratingIP65
Protection classIII
Operating temperature−30 to+65 °C
Storage temperature−40 to+75 °C
Relative humidity≤95%;non-condensing
Ambient light immunityTypical40,000 lx
Vibration resistanceEN60068-2-6 and EN60068-2-64
Shock resistanceEN60068-2-27
MTTFD101 years
DCavg0%
Physical Weight (kg)0.2
Dimensions L x W x H (cm)5.77 x 3.61 x 7.27
Resolution1,000 µm
Measurement accuracy±10 mm at90% remission
Analog output1 ×0–10 V;load≥5,000 Ω
Analog-output resolution16 bit
Output time≥4 ms;continuous change of distance

Industrial Applications

1. Following a container surface level

A container can present a sufficiently reflecting material surface inside the remission-dependent range and use the 0–10 V output as a distance reference for external level control. The controller derives level from the installed geometry and taught analog span. Actual surface return,averaging,warm-up and theload≥5,000 Ω receiving input are checked before selecting process thresholds.

Problem Solved

An analog surface-distance value lets external process control follow changing fill level across a taught span,supplying information for replenishment or filling decisions between fixed switching events.

Level trend Analog distance External geometry

2. Estimating roll size from its outer surface

A roll station can aim the sensor at the outer material surface and send the selected 0–10 V signal to external evaluation. With the roll axis and sensor reference fixed,the controller derives a roll-size estimate from measured distance. The actual surface remission determines usable range,and averaging is selected after checking the rotating material return and required response.

Problem Solved

A distance-derived roll-size estimate gives external unwind or rewind control a changing material reference,helping it follow consumption or build-up beyond a single fixed end-of-roll threshold.

Roll surface External calculation Averaging

3. Combining position feedback with a switching condition

A moving machine assembly can present a natural target within the appropriate remission-dependent range. The analog output passes distance information to an external positioning controller,while the single NPN output reports a taught distance condition for sequence coordination. The controller implements correction;the actual target,receiving load,≥4 ms output-time bound and selected averaging are validated for the intended movement.

Problem Solved

Providing analog distance information alongside a taught switching event lets external control follow position continuously and coordinate a selected sequence condition from the same measured target reference.

Position feedback Switching event External control