Skip to content

Contact Us:
sales@inosaki.com

SICK 1040475 DT500-A311 Analog Laser Distance Sensor

SICK 1040475 DT500-A311 Analog Laser Distance Sensor

USD 2,952.04

DT500-A311 combines laser distance measurement, configurable 0–20 mA or 4–20 mA feedback, ±3 mm accuracy and an M12 connector in an aluminum housing.

SKU: SICK-1040475 Category:
Laser Distance Sensors - SICK Dx500

SICK DT500-A311 Analog Laser Distance Sensor

BrandSICK
Model IdentifierDT500-A311
Official Part Number1040475

Technical Overview

The SICK DT500-A311 is a laser distance sensor that measures natural objects using a visible red Class 2 laser. Its specified measuring range is 0.2–7 m on a target having 90% remission and 0.8–7 m at 6% remission, under constant ambient light up to 1 klx. It provides 12-bit resolution, 1 mm repeatability at one standard deviation and ±3 mm measurement accuracy. A current output can be configured for 0–20 mA or 4–20 mA distance feedback, with 150 ms response and output times. The M12 5-pin connector and IP65 aluminum-diecast housing support machine integration.

Class 2 laser distance sensor with 0.2–7 m range at 90% remission, configurable 0/4–20 mA output, ±3 mm accuracy and 150 ms response.

Key Features

  • Laser distance measurement to natural objects
  • 0.2–7 m measuring range at 90% remission
  • 0.8–7 m at 6% remission; constant ambient light ≤1 klx
  • Visible red Class 2 laser; typical 10 mm spot at 7 m
  • 12-bit resolution; ±3 mm measurement accuracy
  • 1 mm repeatability at 1σ, 6–90% remission
  • Configurable 0–20 mA or 4–20 mA current output
  • 150 ms response and output times
  • 10–30 V DC supply; typical 3 W consumption
  • M12 5-pin connector; IP65 aluminum-diecast housing

Measure distance to natural objects and send a configurable 0–20 mA or 4–20 mA signal through an M12 connection.

Technical Specification Matrix

ParameterValue
Functional principleLaser distance measurement
TargetNatural objects
Measuring range0.2–7 m at 90% remission; 0.8–7 m at 6% remission
Range conditionsConstant ambient light ≤1 klx; unambiguous up to 7 m (not an extension of the specified measuring range)
Resolution12 bit
Repeatability1 mm, statistical error 1σ, 6–90% remission
Measurement accuracy±3 mm
Response time150 ms
Output time150 ms
Light sourceLaser, visible red light
Laser class2, IEC 60825-1:2014 and EN 60825-1:2014
Light spot sizeTypically 10 mm at 7 m
Analog output1 × current output, configurable 0–20 mA or 4–20 mA
Analog load limitMaximum resistance = (supply voltage − 2 V) / 0.0205 A
Multifunctional inputPNP, active HIGH; HIGH = supply voltage minus less than 2 V; LOW <2 V
Laser-off input>12 V
Power supply10–30 V DC, reverse-polarity protected
Power consumptionTypically 3 W
Residual ripple5 Vpp; remain within supply-voltage limits
Initialization time500 ms
ConnectionMale connector M12, 5-pin
Protection classII; reference voltage 32 V DC
Housing materialMetal, aluminum diecast
Window materialGlass
IP ratingIP65
Operating temperature−10 to +45 °C
Extended operating temperature−10 to +75 °C with cooling case
Storage temperature−25 to +75 °C
Temperature driftTypically 0.05 mm/K
Ambient light immunityTypically ≤3,000 lx; specified measuring range uses ≤1 klx constant ambient light
Electromagnetic compatibilityEN 61000-6-2 and EN 61000-6-3
MTTFD101 years
Diagnostic coverage DCavg0%
Dimensions L x W x H (cm)15.3 x 6.9 x 5
Physical Weight (kg)1

Industrial Applications

1. Following material level in a bin

A machine can point the distance sensor at the surface of bulk material and follow the measured distance as inventory rises or falls. Measurement to natural objects avoids a reflector on the material surface. The current output supplies a continuous value to the process controller, which can relate distance to the bin geometry.

Problem Solved

Continuous surface-distance feedback helps the controller follow material use and replenishment without placing a contact probe in the stock or relying on a single full-or-empty switching point.

Natural objects Current output Level feedback

2. Monitoring the diameter of a winding roll

A winding machine can mount the sensor at a fixed position facing the outside of a slowly changing material roll. As the roll grows or unwinds, the measured surface distance changes. The current output feeds this changing distance to the controller, which can relate it to roll diameter using the established mounting geometry.

Problem Solved

A continuous roll-surface measurement helps the winding controller track changing material buildup without a mechanical follower pressing against the roll or marking its outside surface.

Analog feedback Natural target Roll surface

3. Tracking a shuttle against a fixed target

A shuttle can point the sensor toward a stationary natural target along its travel path and monitor the changing distance during movement. The current output provides distance-related feedback to the machine controller. The installed target reflectance and ambient-light conditions establish the usable range, while the specified response time governs how quickly distance changes reach the control system.

Problem Solved

Contactless distance feedback gives the controller a position-related value along the shuttle path without a measuring wheel or cable mechanism following the moving carriage.

Current output Distance feedback Fixed target