Contact Us:
sales@inosaki.com

FL SWITCH 2208 – 2702327 – Phoenix Contact Industrial Ethernet Switches

$ 711.70

SKU Phoenix Contact 2702327 Category

Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.

Commercial Data

Item number 2702327
Packing unit 1 pc
Minimum order quantity 1 pc
Product key DNN121
Catalog page Page 306 (C-6-2019)
GTIN 4055626128931
Weight per piece (including packing) 347 g
Weight per piece (excluding packing) 230 g
Customs tariff number 85176200
Country of origin DE

Notes

General Support by phone or on-site (fee is charged)
Note on application
Note on application Only for industrial use

Interfaces

Ethernet (RJ45)
Connection method RJ45
Note on the connection method Auto negotiation and autocrossing
Transmission speed 10/100 Mbps
Transmission physics Copper
Transmission length 100 m (per segment)
Signal LEDs Data receive, link status
No. of channels 8 (RJ45 ports)

Product Properties

Product type Switch
Product family Managed Switch 2000
Type Book type
MTTF 494.02 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
235.18 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
29.73 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Special properties Extended temperature range
Development process certified in accordance with IEC 62443-4-1
Compatible with IEC 62443-4-2
Signal delay ≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
Insulation characteristics
Protection class III (VDE 0106)
Degree of pollution 2
Switch functions
Diagnostic functions RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance
Basic functions Store-and-forward switch, complies with IEEE 802.3
Signal contact control voltage typ. 24 V DC
PROFINET conformance class Conformance-Class B
PROFINET device function PROFINET device
Fast Startup
Filter functions Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering
IP parameterization DHCP client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol)
MAC address table 8k
Management Web-based management (HTTP/HTTPS)
Role-based user management (LDAP, RADIUS)
SNMPv1/v2/v3
Command Line Interface (Telnet, SSH)
Redundancy MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
PROFINET S2 system redundancy
Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Additional functions Transmission of MMS and GOOSE (IEC 61850-8-1)
Transmission of Modbus/TCP
Time synchronization SNTP (Simple Network Time Protocol)
Security functions
Port security MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass
Basic functions Store-and-forward switch, complies with IEEE 802.3

Electrical Properties

Current consumption 190 mA
Local diagnostics US1/2 Supply voltage US1, US2 Green LED
FAIL Div. LED red
LINK Link status Green LED
Maximum power dissipation for nominal condition 4.95 W (US = Min, Tamb = Max, DOI = Max)
Test section 24 V supply / functional ground 500 V DC 1 min
Ethernet interface/all other potentials 2.25 kV DC 1 min
Transmission medium Copper
Supply
Supply voltage (DC) 24 V DC (redundant)
Supply voltage range 12 V DC … 57 V DC
Power supply connection via COMBICON, max. conductor cross section 1.5 mm²
Residual ripple 3.6 VPP (within the permitted voltage range)
Max. current consumption 1.3 A (US = Min, Tamb = Max, DOI = Max)
Typical current consumption 185 mA (at US = 24 V DC and 25 °C ambient temperature)
Current consumption 190 mA
Function
Signal contact control voltage typ. 24 V DC

Output Data

Digital:
Output name Alarm output

Connection Data

Connection method Push-in spring connection
Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C … 75 °C)
Conductor cross section, rigid 0.25 mm² … 1.5 mm²
Conductor cross section, flexible 0.25 mm² … 1.5 mm²
Conductor cross section AWG 24 … 16
Stripping length 9 mm

Dimension

Width 45 mm
Height 130 mm
Depth 119 mm

Material Specifications

Housing material Polycarbonate fiber reinforced

Environmental and real-life conditions 

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C … 70 °C
Ambient temperature (storage/transport) -40 °C … 85 °C
Permissible humidity (operation) 10 % … 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % … 95 % (non-condensing)
Shock (operation) 30g (EN 60068-2-27)
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation) 80 kPa … 110 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport) 79 kPa … 108 kPa up to 2000 m above mean sea level (Without derating)

Standards And Regulations

Free from substances that could impair the application of coating Yes

Approvals

Shipbuilding approval Tested in accordance with IEC 60945 and IACS E10
ATEX
Identification  II 3 G Ex ec IIC T4 Gc
Certificate DEMKO 16 ATEX 1709X
References to standards EN 60079-0
EN 60079-7
IECEx
Identification Ex ec IIC T4 Gc
Certificate IECEx ULD 16.0018 X
References to standards IEC 60079-0
IEC 60079-7
UL, USA/Canada
Identification cULus
UL Ex, USA / Canada
Identification Class I, Division 2, Groups A, B, C, and D, T4
Class I, Zone 2, AEx ec IIC T4
Ex ec IIC T4 Gc X
Certificate E366272
Note UL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2
EAC Ex
Identification 2Ex e IIC T4 Gc X
Certificate RU C-DE.HB49.B.00118/21
The following continue to apply for EAC Ex:
Identification Install the device in a suitable, approved housing with at least IP66 protection.
The housing/control cabinet must be equipped with a warning sign prohibiting opening in the potentially explosive area.
The operation of devices is permitted if all optical ports are connected or sealed with the supplied filler plugs.
CCC / China-Ex
Identification Ex ec IIC T4 Gc
Certificate 2022122310115629
Corrosive gas test
Identification ISA S71.04.2013 G3 Harsh Group A
UKCA Ex (UKEX)
Identification  II 3 G Ex ec IIC T4 Gc
Certificate PxCIMA22UKEX2702910X
Shipbuilding data
Temperature B
Humidity B
Vibration A
EMC B
Enclosure Required protection according to the Rules shall be provided upon installation on board

EMC Data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Conformance with EMC directives EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Noise immunity EN 61000-6-2
Noise emission
Standards/regulations EN 61000-6-4

System Properties

Functionality
Basic functions Store-and-forward switch, complies with IEEE 802.3

Signaling

Status display LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)

Mounting

Mounting type DIN rail mounting

Additional information

Weight 0.347 kg
Dimensions 11.9 × 4.5 × 13 cm

Related Products

SICK_sensor_Non-contact safety switches_IME2S_IME2S12_04B4DW2
SCHNEIDER_Logic Controller,Modicon M221,16 IO Transistor PNP Ethernet
Banner_Q12AB6FF15Q
Internal Thread Straight Through Pneumatic PU Trachea Quick Connector
Phoenix_Contact_End_Cover_D-UK-5-TWIN-_1923034
SICK_sensor_Distance sensor_OD Mini_OD1-B035H15I25
Select your currency