Item number | 2702327 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DNN121 |
Catalog page | Page 306 (C-6-2019) |
GTIN | 4055626128931 |
Weight per piece (including packing) | 347 g |
Weight per piece (excluding packing) | 230 g |
Customs tariff number | 85176200 |
Country of origin | DE |
General | Support by phone or on-site (fee is charged) |
Note on application | |
Note on application | Only for industrial use |
Ethernet (RJ45) | |
Connection method | RJ45 |
Note on the connection method | Auto negotiation and autocrossing |
Transmission speed | 10/100 Mbps |
Transmission physics | Copper |
Transmission length | 100 m (per segment) |
Signal LEDs | Data receive, link status |
No. of channels | 8 (RJ45 ports) |
Product type | Switch |
Product family | Managed Switch 2000 |
Type | Book type |
MTTF | 494.02 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
235.18 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
29.73 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) | |
Special properties | Extended temperature range |
Development process certified in accordance with IEC 62443-4-1 | |
Compatible with IEC 62443-4-2 | |
Signal delay | ≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
Insulation characteristics | |
Protection class | III (VDE 0106) |
Degree of pollution | 2 |
Switch functions | |
Diagnostic functions | RMON History |
LLDP (Link Layer Discovery Protocol) | |
SNMP-Traps | |
N:1-Portmirroring | |
ACD (Address Conflict Detection) | |
SysLog | |
CRC-Surveillance | |
Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
Signal contact control voltage | typ. 24 V DC |
PROFINET conformance class | Conformance-Class B |
PROFINET device function | PROFINET device |
Fast Startup | |
Filter functions | Quality of Service (8 priority classes) |
Class of Service | |
DiffServ/DSCP | |
Port-Priorisierung | |
VLAN (up to 32 VLANs) | |
IGMP Snooping/Querier (v1/v2) | |
Auto-Query-Port | |
Extended Multicast Filtering | |
IP parameterization | DHCP client |
DHCP Option 82 (Relay Agent) | |
DHCP server (pool-based, port-based) | |
BootP | |
DCP (Discovery and Configuration Protocol) | |
MAC address table | 8k |
Management | Web-based management (HTTP/HTTPS) |
Role-based user management (LDAP, RADIUS) | |
SNMPv1/v2/v3 | |
Command Line Interface (Telnet, SSH) | |
Redundancy | MRP (Media Redundancy Protocol) |
RSTP (Rapid Spanning Tree Protocol) | |
FRD (Fast Ring Detection) | |
Large Tree Support | |
LACP (Link Aggregation Control Protocol) | |
PROFINET S2 system redundancy | |
Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
Additional functions | Transmission of MMS and GOOSE (IEC 61850-8-1) |
Transmission of Modbus/TCP | |
Time synchronization | SNTP (Simple Network Time Protocol) |
Security functions | |
Port security | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
Current consumption | 190 mA |
Local diagnostics | US1/2 Supply voltage US1, US2 Green LED |
FAIL Div. LED red | |
LINK Link status Green LED | |
Maximum power dissipation for nominal condition | 4.95 W (US = Min, Tamb = Max, DOI = Max) |
Test section | 24 V supply / functional ground 500 V DC 1 min |
Ethernet interface/all other potentials 2.25 kV DC 1 min | |
Transmission medium | Copper |
Supply | |
Supply voltage (DC) | 24 V DC (redundant) |
Supply voltage range | 12 V DC … 57 V DC |
Power supply connection | via COMBICON, max. conductor cross section 1.5 mm² |
Residual ripple | 3.6 VPP (within the permitted voltage range) |
Max. current consumption | 1.3 A (US = Min, Tamb = Max, DOI = Max) |
Typical current consumption | 185 mA (at US = 24 V DC and 25 °C ambient temperature) |
Current consumption | 190 mA |
Function | |
Signal contact control voltage | typ. 24 V DC |
Digital: | |
Output name | Alarm output |
Connection method | Push-in spring connection |
Note on the connection method | Use only copper connecting cables providing the permitted temperature range (-40 °C … 75 °C) |
Conductor cross section, rigid | 0.25 mm² … 1.5 mm² |
Conductor cross section, flexible | 0.25 mm² … 1.5 mm² |
Conductor cross section AWG | 24 … 16 |
Stripping length | 9 mm |
Width | 45 mm |
Height | 130 mm |
Depth | 119 mm |
Housing material | Polycarbonate fiber reinforced |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -40 °C … 70 °C |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Permissible humidity (operation) | 10 % … 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % … 95 % (non-condensing) |
Shock (operation) | 30g (EN 60068-2-27) |
Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Air pressure (operation) | 80 kPa … 110 kPa up to 2000 m above mean sea level (Without derating) |
Air pressure (storage/transport) | 79 kPa … 108 kPa up to 2000 m above mean sea level (Without derating) |
Free from substances that could impair the application of coating | Yes |
Shipbuilding approval | Tested in accordance with IEC 60945 and IACS E10 |
ATEX | |
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | DEMKO 16 ATEX 1709X |
References to standards | EN 60079-0 |
EN 60079-7 | |
IECEx | |
Identification | Ex ec IIC T4 Gc |
Certificate | IECEx ULD 16.0018 X |
References to standards | IEC 60079-0 |
IEC 60079-7 | |
UL, USA/Canada | |
Identification | cULus |
UL Ex, USA / Canada | |
Identification | Class I, Division 2, Groups A, B, C, and D, T4 |
Class I, Zone 2, AEx ec IIC T4 | |
Ex ec IIC T4 Gc X | |
Certificate | E366272 |
Note | UL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2 |
EAC Ex | |
Identification | 2Ex e IIC T4 Gc X |
Certificate | RU C-DE.HB49.B.00118/21 |
The following continue to apply for EAC Ex: | |
Identification | Install the device in a suitable, approved housing with at least IP66 protection. |
The housing/control cabinet must be equipped with a warning sign prohibiting opening in the potentially explosive area. | |
The operation of devices is permitted if all optical ports are connected or sealed with the supplied filler plugs. | |
CCC / China-Ex | |
Identification | Ex ec IIC T4 Gc |
Certificate | 2022122310115629 |
Corrosive gas test | |
Identification | ISA S71.04.2013 G3 Harsh Group A |
UKCA Ex (UKEX) | |
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | PxCIMA22UKEX2702910X |
Shipbuilding data | |
Temperature | B |
Humidity | B |
Vibration | A |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A | |
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A | |
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B | |
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A | |
EN 61000-6-2 EN 61000-6-4 (interference) Class A | |
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A | |
Noise immunity | EN 61000-6-2 |
Noise emission | |
Standards/regulations | EN 61000-6-4 |
Functionality | |
Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
Status display | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
Mounting type | DIN rail mounting |
Weight | 0.347 kg |
---|---|
Dimensions | 11.9 × 4.5 × 13 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)