SICK 1044075 FX0-GPRO00000 Flexi Soft PROFIBUS DP Gateway

USD 723.32

FX0-GPRO00000 links Flexi Soft to PROFIBUS DP for non-safety control and diagnostic data, with a nine-pin D-Sub socket and FLEXBUS+ power supply.

SKU SICK-1044075 Category
SICK Safety Controllers

SICK FX0-GPRO00000 Flexi Soft PROFIBUS DP Gateway

BrandSICK
Model IdentifierFX0-GPRO00000
Official Part Number1044075

Technical Overview

The SICK FX0-GPRO00000 is a PROFIBUS DP gateway for a compatible Flexi Soft system. It exchanges non-safety control and diagnostic data with an external fieldbus controller, using Flexi Soft Designer for configuration. A nine-pin D-Sub female connector supports transmission rates up to 12,000 kbit/s depending on cable length. Supply comes through FLEXBUS+, with internal consumption no more than 1.6 W and protection class III. IP20 protection, −25 to +55 °C operation and non-condensing humidity up to 95% define installation conditions. The gateway requires the Flexi Soft system and qualified integration; its fieldbus data must not be used as a safety communication channel.

Flexi Soft PROFIBUS DP gateway for non-safety control and diagnostic data, with nine-pin D-Sub female connection and FLEXBUS+ supply.

Key Features

  • Gateway module for a compatible Flexi Soft system
  • PROFIBUS DP industrial network
  • Non-safety control and diagnostic data exchange
  • Configuration with Flexi Soft Designer software
  • One nine-pin D-Sub female connector
  • Up to 12,000 kbit/s depending on cable length
  • Supply via FLEXBUS+; internal consumption ≤1.6 W
  • Protection class III to EN 61140; IP20 to EN 60529
  • −25 to +55 °C operation; relative humidity ≤95%, non-condensing

Exchange configured non-safety status and control data between a compatible Flexi Soft system and PROFIBUS DP network.

Technical Specification Matrix

ParameterValue
Module typeFlexi Soft gateway
FieldbusPROFIBUS DP
Data purposeNon-safety control and diagnostic data exchange
System requirementOnly with a compatible Flexi Soft system; main-module firmware ≥V1.11.0 and Flexi Soft Designer ≥V1.3.0 according to the gateway manual
Safety integrationNot for safety-related fieldbus communication; qualified safety personnel must check system integration
ConfigurationFlexi Soft Designer software
Transmission rateUp to 12,000 kbit/s, depending on cable length
Network connectionOne female D-Sub nine-pin connector
Power supplyVia FLEXBUS+
Internal power consumption≤1.6 W via FLEXBUS+
Protection classIII, EN 61140
IP ratingIP20, EN 60529
Operating temperature−25 to +55 °C
Storage temperature−25 to +70 °C
Relative humidity≤95%, non-condensing
Dimensions L x W x H (cm)12.6 x 2.91 x 9.65

Industrial Applications

1. Displaying machine status on a supervisory screen

A compatible Flexi Soft installation can send configured non-safety status data through the gateway to a PROFIBUS DP controller. A supervisory screen can then present those values to operators using a documented data map. Commissioning checks the displayed meaning against the configured system and verifies communication behavior, while the machine’s protective functions remain subject to their separate validated safety design.

Problem Solved

A shared status-data path helps a supervisory display show configured machine conditions, with fieldbus values interpreted through the commissioned non-safety data mapping.

Status display PROFIBUS DP Non-safety data

2. Collecting diagnostic information for maintenance

Maintenance monitoring can receive configured Flexi Soft diagnostic data through the PROFIBUS DP gateway and associate it with the appropriate machine section. Engineering establishes the supported data map in Flexi Soft Designer, then checks how normal states and relevant diagnostic conditions appear in the external controller. Fieldbus information supports investigation without replacing the required local checks or validated protective functions.

Problem Solved

Configured diagnostic information helps maintenance monitoring identify the relevant machine section and investigate its condition, using a documented non-safety communication path to the external controller.

Maintenance diagnostics Configured mapping External monitoring

3. Checking configured process-data exchange during commissioning

Commissioning staff can exercise the configured non-safety data exchange between a Flexi Soft system and its external PROFIBUS DP controller. Checks compare known system conditions with the received values and confirm the intended interpretation of data sent back. The selected transmission rate respects cable length, and qualified personnel assess the effect of fieldbus data on the complete application.

Problem Solved

A controlled data-exchange check helps engineering confirm mapping and interpretation before normal operation, using the supported network connection and required qualified integration review.

Commissioning Data mapping Qualified integration