SICK FXL1-SPBUSA00 flexLock Safety Locking Device

BrandSICK
Model IdentifierFXL1-SPBUSA00
Official Part Number1101320

Technical Overview

The SICK FXL1-SPBUSA00 flexLock is a uniquely coded RFID safety locking device using the power-to-release principle. Its two self-monitoring PNP OSSDs report locking monitoring, while a separate diagnostic output reports actuator monitoring. Component ratings include SIL 3, category 4 and PL e for door-position and locking monitoring. Locking force depends on the actuator and approach direction; the actuator is ordered separately. Safe series connection is supported through control-cabinet wiring, Flexi Loop or T-connectors, with diagnostics depending on the selected arrangement. The device uses 24 V DC, an eight-pin M12 connector and a VISTAL housing with IP65/IP67/IP69K protection. Response and release timing increase in a safe series connection.

Uniquely coded RFID power-to-release safety locking device with two monitored PNP OSSDs, separate actuator diagnostic output and eight-pin M12 connection.

Key Features

  • Uniquely coded RFID; high coding level; type 4 to EN ISO 14119
  • Power-to-release locking; auxiliary release provided
  • Two self-monitoring PNP OSSDs with short-circuit protection and cross-circuit monitoring
  • OSSD locking monitoring; separate actuator-monitoring diagnostic output
  • SIL 3; category 4 and PL e for door-position and locking monitoring
  • Actuator-dependent locking force; actuator not supplied
  • Safe series connection: control cabinet or Flexi Loop with diagnostics; T-connector without diagnostics
  • 24 V DC, 19.2–28.8 V; eight-pin M12 connector with stainless-steel coupling nut
  • VISTAL housing; IP65/IP67/IP69K; 480 g product weight
  • −20 to +55 °C operation; 1,000,000 mechanical switching cycles

Monitor guard locking through two OSSDs and read actuator presence separately, selecting the actuator and series arrangement for the installed guard geometry.

Technical Specification Matrix

ParameterValue
Sensor principleRFID
Locking principlePower to release
CodingUniquely coded; high coding level, EN ISO 14119
Device typeType 4, EN ISO 14119
Actuator supplyActuator not included
Locking force FmaxFlexible actuator: 4,100 N; rigid frontal: 3,630 N; rigid lateral: 3,510 N; EN ISO 14119
Locking force FZhFlexible actuator: 3,150 N; rigid frontal: 2,790 N; rigid lateral: 2,700 N; EN ISO 14119
Actuation force20 N
Retaining force30 N
Unlocking against force≤25 N
Actuation frequency≤1 Hz
Approach speed≤20 m/min
Safety integrity levelSIL 3, IEC 61508
Category and performance levelCategory 4 and PL e, EN ISO 13849; applies to door-position and locking monitoring
PFHD9.55 × 10⁻⁹ per hour at 40 °C and 0 m above sea level
Mission time20 years, EN ISO 13849
Fault safe stateAt least one safety-related semiconductor output (OSSD) OFF
Auxiliary releaseProvided
Safety outputsTwo self-monitoring PNP OSSDs; short-circuit protected and cross-circuit monitored; locking monitoring
Diagnostic outputActuator monitoring; not safe
Series connectionControl cabinet with diagnostics; Flexi Loop with diagnostics; T-connector without diagnostics
ConnectionM12 eight-pin plug connector; stainless-steel coupling nut
Pin assignment1=Out AUX (not safe); 2=+24 V; 3=LOCK input; 4=In2 enable; 5=OSSD1; 6=OSSD2; 7=0 V; 8=In1 enable
Enable inputsFor individual device or first device in a safe series connection, apply 24 V DC to In1 and In2
IndicatorsLED diagnostics and status indication
Power supply24 V DC; 19.2–28.8 V DC
Current consumption65 mA unlocked; 65 mA locked
Peak current800 mA for 200 ms
Safety output current≤100 mA
Diagnostic output current≤50 mA
Output voltageSupply voltage −2 V DC to supply voltage
Response time≤150 ms; add 70 ms for each additional switch in safe series connection
Release time≤350 ms; add 70 ms for each additional switch in safe series connection
Risk time150 ms; add 70 ms for each additional switch in safe series connection
Switch-on time3 s
Protection classIII, IEC 61140
Contamination rating3, IEC 60947-1
cULus classificationClass 2
Usage categoryDC-13, IEC 60947-5-3
Rated insulation voltage32 V
Rated impulse withstand voltage1,500 V
Housing materialVISTAL
Mechanical materialsStainless-steel ball bracket, actuator latch plate and plug connectors
Mechanical life1,000,000 switching cycles
IP ratingIP65/IP67, IEC 60529; IP69K, IEC 20653
Operating temperature−20 to +55 °C
Storage temperature−25 to +70 °C
Relative humidity10–95% at 40 °C, IEC 60068
Vibration resistance10–55 Hz, 1 mm; IEC 60068-2-6
Shock resistance30 g, 11 ms; EN 60068-2-27
EMCEN IEC 61326-3-1; EN IEC 60947-5-2; EN IEC 60947-5-3; EN 300330
Physical Weight (kg)0.48
Dimensions L x W x H (cm)4.8 x 4 x 19.44

Industrial Applications

1. Monitoring the lock on a machine access guard

A machine access guard can present a separately selected flexLock actuator to the uniquely coded locking device. External safety evaluation reads both OSSDs for the locking-monitoring condition, while the machine control manages the power-to-release request. Installation selects the appropriate actuator and approach direction, and the protective-function design accounts for the specified response, release and startup timing.

Problem Solved

A monitored locking condition gives the external safety system a defined input for coordinating guard access with machine operation, using the actuator-specific locking arrangement and validated system timing.

Guard locking Dual OSSDs Power to release

2. Connecting several guarded access points in a monitored series

A machine with several access points can connect compatible flexLock devices in a documented safe series arrangement. Control-cabinet wiring or Flexi Loop retains diagnostics, while the specified T-connector arrangement does not. The external safety design includes the additional 70 ms per further switch in response, release and risk timing, alongside the selected actuator geometry at every guard.

Problem Solved

A documented series arrangement gives the external safety system a way to evaluate several access points, with diagnostic availability and accumulated timing considered in the installed protective function.

Series guards Flexi Loop Timing allowance

3. Displaying actuator presence during guard alignment

During guard alignment, ordinary machine diagnostic logic can read the separate actuator-monitoring output and the local LED indications. These signals help distinguish actuator presentation from the OSSDs’ locking-monitoring condition. Setup checks the selected approach geometry and reads the diagnostic signal within its 50 mA limit, while the external safety system continues to evaluate the two dedicated OSSDs.

Problem Solved

Separate actuator feedback helps maintenance personnel review guard alignment and presence information, keeping ordinary diagnostic display logic tied to the documented actuator-monitoring signal and its electrical limits.

Guard alignment Actuator diagnostics LED indication