SICK 1059923 GL6-N1211 NPN Retro-Reflective Sensor

USD 54.34

GL6-N1211 combines polarised red-light detection, NPN output and 1,000 Hz switching with a 2 m cable in an IP67 housing.

SKU SICK-1059923 Category
SICK G6

SICK GL6-N1211 Retro-Reflective Photoelectric Sensor

BrandSICK
Model IdentifierGL6-N1211
Official Part Number1059923

Technical Overview

The SICK GL6-N1211 is a polarised retro-reflective photoelectric sensor with a NPN output and visible red PinPoint LED. A passive reflector returns the transmitted beam to the sensor, and an opaque object is detected when it interrupts this path. With a PL80A reflector, the specified sensing range is 0.07–5 m and the maximum range is 0.03–6 m. The dual-lens optical system requires a minimum reflector distance, while selectable light/dark switching adapts the electrical signal logic. A response below 625 µs, 1,000 Hz switching frequency, 2 m PVC cable and IP67 ABS/PC housing support installation in material-handling machines. A 270° potentiometer adjusts sensitivity.

NPN polarised retro-reflective sensor with 1,000 Hz switching, 2 m PVC cable and IP67 protection.

Key Features

  • Polarised retro-reflective sensing with dual-lens optics
  • 650 nm visible red PinPoint LED
  • 0.07–5 m sensing range with PL80A reflector
  • 0.03–6 m maximum range with PL80A reflector
  • Ø 8 mm light spot at 350 mm
  • NPN output; selectable light/dark switching
  • Response < 625 µs; 1,000 Hz switching frequency
  • 10–30 V DC; 2 m PVC cable
  • IP67 ABS/PC housing; −25 to +55 °C operation
  • 270° sensitivity potentiometer

Detect interrupted beam paths with a polarised sensor and passive reflector, keeping electrical wiring on one side of the conveyor.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor; dual-lens system with minimum reflector distance
Sensing range0.07–5 m with PL80A reflector
Maximum sensing range0.03–6 m with PL80A reflector
Light sourcePinPoint LED, visible red light
Wavelength650 nm
Light spot sizeØ 8 mm at 350 mm
AdjustmentPotentiometer, 270°
Power supply10–30 V DC; short-circuit-protected network, max. 8 A
Residual ripple±10%; remain within supply-voltage limits
Current consumption30 mA, without load
Protection classIII
Switching outputNPN
Switching modeLight/dark switching; selectable via rotary selector
Output current≤ 100 mA; maximum 50 mA above 24 V supply
Response time< 625 µs with resistive load
Switching frequency1,000 Hz at light/dark ratio 1:1
Circuit protectionSupply and input/output reverse-polarity protection; output overcurrent and short-circuit protection
Housing formRectangular
Connection3-wire, 2 m cable; brown L+, blue M, black Q
Housing materialABS/PC plastic
Front screen materialPMMA plastic
Cable materialPVC plastic; do not bend below 0 °C
IP ratingIP67
Operating temperature−25 to +55 °C; temperature stability after adjustment ±10 °C
Storage temperature−40 to +70 °C
MountingM3 mounting holes
IndicatorsGreen supply-voltage LED; yellow received-light indicator
Output signal voltageApproximately supply voltage / ≤ 3 V (HIGH/LOW)
Physical Weight (kg)0.06
Dimensions L x W x H (cm)2.1 x 1.2 x 3.15
Polarisation filterYes
Reflector selectionSensing distance depends on reflector type; quoted 5 m/6 m ranges require PL80A
MTTFD1,609 years

Industrial Applications

1. Counting separated opaque cartons

A carton conveyor can place the sensor on one side and a passive reflector on the other. Each opaque carton interrupts the returned red beam, producing a NPN switching event for the counter. Polarised retro-reflective sensing provides the optical path, while the 1,000 Hz switching frequency supports repeated transitions within the specified timing limits.

Problem Solved

The reflector needs no electrical supply, reducing wiring across the conveyor while the machine receives a discrete event for each separated carton that interrupts the beam.

Polarised retro-reflective NPN 1,000 Hz

2. Monitoring accumulation at a transfer point

At a conveyor transfer, a load that remains between the sensor and reflector holds the received-light signal in the blocked state. The machine controller can use this duration to identify sustained occupancy and regulate upstream release. Selectable light/dark switching adapts the signal polarity, while the 2 m PVC cable connects the sensor to local machine wiring.

Problem Solved

A sustained beam blockage identifies a transfer position that remains occupied, helping the controller coordinate upstream feeding before additional loads enter the same constrained space.

Light/dark switching 2 m PVC cable Beam interruption

3. Checking opaque sheet continuity

An opaque sheet feeder can direct the returned beam through the expected material path. The sensor detects whether the material continues to block that path, and an opening caused by runout or a break changes its switching state. IP67 protection suits exposed machine mounting, while the visible red beam assists positioning during initial setup.

Problem Solved

A change in the received-light state gives the controller an electrical indication of missing material at the monitoring position, supporting an orderly response to interrupted feed.

IP67 Visible red light Material continuity