SICK 1050708 GL6-P1111 PNP Retro-reflective Sensor

USD 45.76

GL6-P1111 offers polarized red-light sensing over 0.07–5 m with PL80A, selectable PNP light/dark switching, no sensitivity adjustment and a 2 m cable.

SKU SICK-1050708 Category
SICK G6

SICK GL6-P1111 PNP Retro-reflective Sensor

BrandSICK
Model IdentifierGL6-P1111
Official Part Number1050708

Technical Overview

The SICK GL6-P1111 is a polarized photoelectric retro-reflective sensor with a red PinPoint LED and PNP output. Dual-lens optics require a minimum reflector distance. With PL80A, sensing spans 0.07–5 m and maximum range is 0.03–6 m. There is no sensitivity adjustment; a light/dark selector chooses output behavior. Response is below 625 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The 650 nm LED produces an 8 mm spot at 350 mm. A 2 m three-wire PVC cable connects the 10–30 V DC device. Its ABS/PC housing and PMMA front screen provide IP67 protection, with M3 mounting holes for installation.

PNP Retro-reflective Sensor with 0.07–5 m PL80A sensing, no sensitivity adjustment, selectable light/dark mode and 2 m PVC cable.

Key Features

  • Polarized photoelectric retro-reflective sensor; dual-lens optics require minimum reflector distance
  • Sensing range: 0.07–5 m with PL80A reflector
  • Maximum range: 0.03–6 m with PL80A reflector
  • 650 nm visible red PinPoint LED; Ø8 mm at 350 mm
  • No sensitivity adjustment; separate light/dark selector
  • PNP output with selectable light/dark mode
  • <625 µs response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 30 mA without load; output ≤100 mA, reduced to 50 mA above 24 V
  • 2 m three-wire PVC cable; do not bend below 0 °C
  • IP67; ABS/PC housing; PMMA front screen; M3 mounting holes

Monitor interruptions of a returned red beam using a compatible reflector and connect the selected PNP switching state to external process control.

Technical Specification Matrix

ParameterValue
Functional principlePolarized photoelectric retro-reflective sensor; dual-lens optics require minimum reflector distance
Housing designRectangular
Sensing range0.07–5 m with PL80A reflector
Maximum sensing range0.03–6 m with PL80A reflector
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeØ8 mm at 350 mm
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentNone
Switching outputPNP switching output
Switching modeLight/dark switching, selectable via rotary selector (L=light; D=dark)
Signal voltage HIGH/LOWSupply voltage −(≤3 V) / approximately 0 V
Output current≤100 mA; at supply voltage >24 V, maximum 50 mA
Response time<625 µs with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A
Ripple±10%; remain within supply tolerances
Current consumption30 mA without load
Connection2 m three-wire PVC cable; do not bend below 0 °C
Electrical protectionSupply reverse-polarity protection; input and output reverse-polarity protection; output overcurrent and short-circuit protection
Housing materialABS/PC
Optics materialPMMA
IP ratingIP67
Operating temperature−25 to +55 °C; temperature stability following adjustment ±10 °C
Storage temperature−40 to +70 °C
MTTFD2,141 years
Diagnostic coverageDCavg 0%
MountingM3 threaded mounting holes
IndicatorsGreen: supply voltage active; yellow: received-light status
Protection classIII
UL filesNRKH.E348498 and NRKH7.E348498
Polarization filterYes
Mission time20 years
Conductor cross-section0.14 mm²
Wire assignmentCD-043: BN=L+; BU=M; BK=Q
Reflector-specific rangesSensing / maximum: PL80A 0.07–5 / 0.03–6 m; PL40A 0.07–3.8 / 0.03–4.3 m; P250 0.07–3.5 / 0.03–4 m; PL20A 0.07–2.2 / 0.03–2.5 m; REF-IRF-56 tape 0.25–1.6 / 0.2–1.8 m
Physical Weight (kg)0.06

Industrial Applications

1. Counting separated opaque loads across a conveyor

A conveyor can position the sensor opposite a compatible reflector so each separated opaque load interrupts the returned red beam. External counting logic reads the PNP output using the selected light/dark behavior. Commissioning verifies reflector-specific sensing distances, alignment, load gaps and transit timing against the response-time and switching-frequency conditions.

Problem Solved

A returned-beam interruption provides external counting logic with a load-passage event, using commissioned reflector geometry and output behavior matched to the connected machine input.

Conveyor counting Reflector path PNP output

2. Monitoring opaque feed continuity

An opaque material feed can occupy the beam between the sensor and a compatible reflector. A gap or runout changes the received-light condition for external feed monitoring. Setup selects light/dark behavior, aligns the reflector and checks that the material covers the optical path throughout normal movement, including the smallest interruption that must be recognized.

Problem Solved

A changed beam condition helps external feed monitoring identify missing material at the sensing point, using a verified optical path and selected switching behavior for the actual feed.

Feed continuity Opaque material Light/dark selection

3. Monitoring occupancy at a transfer point

A conveyor transfer can place the reflected beam through the location that must clear before another load is released. External sequencing logic distinguishes a brief passing interruption from sustained occupancy by evaluating output duration. Commissioning verifies the installed reflector distance, load coverage and light/dark selection, then tests the actual transfer sequence with representative loads.

Problem Solved

A sustained beam interruption supplies an occupancy reference to external sequencing logic, helping coordinate upstream load release when the monitored transfer location remains occupied.

Transfer occupancy External timing Reflector alignment
Select your currency