SICK 1066557 GRL18-P2432 Complementary PNP Retro-reflective Sensor

USD 80.34

GRL18-P2432 offers polarized red-light sensing, 0.06–6 m PL80A range, complementary PNP outputs, 270° sensitivity adjustment and M12 four-pin connection.

SKU SICK-1066557 Category
SICK GR18

SICK GRL18-P2432 Complementary PNP Retro-reflective Sensor

BrandSICK
Model IdentifierGRL18-P2432
Official Part Number1066557

Technical Overview

The SICK GRL18-P2432 is an axial polarized dual-lens retro-reflective sensor with complementary PNP outputs. With PL80A, sensing spans 0.06–6 m and maximum range is 0.03–7.2 m; other reflector types have separate range limits. Its 650 nm red PinPoint LED produces a 175 mm spot at 7 m. A 270° potentiometer adjusts sensitivity. Response is below 500 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The 10–30 V DC device uses an M12 four-pin connector and an M18 × 1 nickel-plated brass/ABS housing with PMMA optics and IP67 protection. Two metal fastening nuts are supplied. Output current and ambient-temperature limits depend on supply voltage and loading.

Axial M18 retro-reflective sensor with 0.06–6 m PL80A sensing, complementary PNP outputs, 270° sensitivity adjustment and M12 four-pin connector.

Key Features

  • Axial polarized dual-lens retro-reflective sensing; minimum reflector distance required
  • PL80A: 0.06–6 m sensing; 0.03–7.2 m maximum range
  • 650 nm red PinPoint LED; Ø175 mm spot at 7 m
  • 270° sensitivity potentiometer
  • Complementary PNP outputs; light/dark switching
  • ≤100 mA output; maximum 50 mA above 24 V or above +49 °C ambient
  • <500 µs response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; M12 four-pin male connector
  • M18 × 1 nickel-plated brass/ABS housing; PMMA optics; IP67
  • Two metal fastening nuts supplied; 24 mm across flats

Adjust the reflected-beam sensing path and connect complementary PNP signals to external counting or sequencing logic through an M12 connector.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor
Optical designAxial polarized dual-lens system; minimum reflector distance required
Sensing range0.06–6 m with PL80A
Maximum sensing range0.03–7.2 m with PL80A
Reflector rangesSensing / maximum: PL80A 0.06–6 / 0.03–7.2 m; PL40A 0.06–5.2 / 0.03–6.2 m; PL20A 0.06–2.9 / 0.03–3.8 m; P250 0.06–5.4 / 0.03–6.4 m; PL22 0.06–1.9 / 0.03–2.2 m; REF-Plus 3436 tape 0.08–1.6 / 0.06–2 m
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeØ175 mm at 7 m
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentSensitivity potentiometer, 270°
Switching outputComplementary PNP outputs
Switching modeLight/dark switching
Signal voltage HIGH/LOWSupply voltage minus a drop ≤3 V / approximately 0 V
Output current≤100 mA; maximum 50 mA at supply voltage >24 V or ambient temperature >+49 °C
Response time<500 µs with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A
Ripple<5 Vpp; remain within supply tolerances
Current consumption30 mA
ConnectionM12 four-pin male connector
Pin assignment1 BN=L+; 2 WH=Q̅; 3 BU=M; 4 BK=Q
Circuit protectionA: supply reverse-polarity protection; B: inputs and output reverse-polarity protection; D: outputs overcurrent and short-circuit protection
Protection classIII
Housing materialNickel-plated brass and ABS
Optics materialPMMA plastic
Mounting threadM18 × 1
IP ratingIP67
Items suppliedTwo metal fastening nuts, 24 mm across flats
IndicatorsGreen static on: power on; yellow static on: object absent; yellow off: object present
Operating temperature−25 to +55 °C at supply ≤24 V and output current <50 mA
Storage temperature−40 to +70 °C
EMCEN 60947-5-2
UL fileE348498
MTTFD1,672 years
DCavg0%

Industrial Applications

1. Counting separated cartons across a conveyor

A conveyor can position the sensor and a suitable reflector on opposite sides of a load path so opaque cartons interrupt the returned red beam. External counting logic evaluates the complementary PNP signal. Commissioning checks reflector spacing, alignment, carton coverage, load gaps and transit speed against the documented reflector ranges, response time and switching frequency before registering passage events.

Problem Solved

A carton-passage reference gives an external counter a defined optical event across the conveyor, using beam interruption and a reflector arrangement checked for the actual load path.

Carton counting Beam interruption complementary PNP signal

2. Monitoring opaque web continuity at a feed point

A material feed can route an opaque web through the reflected optical path between the sensor and a reflector. External process logic samples the complementary PNP signal to evaluate material presence and recognize a break. Setup checks web movement, optical coverage, alignment and the reflector-specific minimum separation, keeping the beam reliably covered throughout normal feed conditions.

Problem Solved

A beam-interruption reference helps external process logic recognize loss of opaque feed at the checked location, using a material path that blocks the reflected beam during normal operation.

Web continuity Opaque material Reflector setup

3. Checking transfer-path occupancy at a stop

A transfer stop can present an opaque carrier across the sensor-to-reflector path at a defined seated position. External sequencing logic samples the complementary PNP state after the carrier settles and coordinates acceptance or release. Installation checks reflector distance, alignment, carrier coverage and possible openings through the carrier so the occupied condition remains distinguishable from the clear path.

Problem Solved

A carrier-occupancy reference helps external sequencing logic coordinate a transfer step, using a defined optical interruption checked at the actual stopped position before release.

Transfer occupancy Stopped carrier complementary PNP signal
Select your currency