Skip to content

Contact Us:
sales@inosaki.com

SICK 6053788 i10-E0354 Lock Power-to-Lock Process Switch

SICK 6053788 i10-E0354 Lock Power-to-Lock Process Switch

USD 313.30

i10-E0354 Lock provides power-to-lock process protection, 1,000 N FZh locking force, door/solenoid monitoring contacts and an M12 eight-pin connector.

SKU: SICK-6053788 Category:
SICK Safety Switches

SICK i10-E0354 Lock Process Protection Locking Switch

BrandSICK
Model Identifieri10-E0354 Lock
Official Part Number6053788

Technical Overview

The SICK i10-E0354 Lock is an electromechanical power-to-lock device specified for process protection only. It provides a 1,000 N FZh locking force and 1,300 N maximum locking force, with one positive-action N/C solenoid-monitoring contact and two positive-action N/C door-monitoring contacts. Four actuation directions and an approach speed up to 20 m/min support mechanical arrangement around a separately ordered actuator. The solenoid uses 20.4–26.4 V DC with 100% duty cycle and consumption up to 8 W. An M12 eight-pin plug connector and IP67 glass-fiber-reinforced thermoplastic housing support installation; external safety-related logic performs fault detection because the switch has no internal fault detection.

Power-to-lock electromechanical switch for process protection only, with 1,000 N FZh locking force, monitoring contacts and separately ordered actuator.

Key Features

  • Electromechanical power-to-lock device for process protection only
  • FZh locking force 1,000 N; maximum locking force 1,300 N, EN ISO 14119
  • One positive-action N/C solenoid-monitoring contact
  • Two positive-action N/C door-monitoring contacts
  • Four actuation directions; approach speed ≤20 m/min; actuation frequency ≤1,200/h
  • Actuation force ≥10 N; retaining force ≤20 N
  • 20.4–26.4 V DC solenoid supply; 100% duty cycle; ≤8 W consumption
  • M12 eight-pin plug connector; brass coupling nut; actuator not supplied
  • Glass-fiber-reinforced thermoplastic housing; IP67; product weight 0.5 kg
  • −20 to +55 °C operation/storage; fault detection requires connected safety-related logic

Hold a process closure using power-to-lock operation and monitor door and solenoid states through separate contact functions; the actuator is ordered separately.

Technical Specification Matrix

ParameterValue
Sensor principleElectromechanical
Intended locking useFor process protection only
Locking principlePower to lock
Solenoid monitoring contactsOne positive-action N/C; zero N/O
Door monitoring contactsTwo positive-action N/C; zero N/O; zero additional N/C contacts
Locking force FZh1,000 N, EN ISO 14119
Maximum locking force Fmax1,300 N, EN ISO 14119
Actuation force≥10 N
Retaining force≤20 N
Actuation frequency≤1,200 per hour
Actuation directionsFour
Approach speed≤20 m/min
B10d3 × 10⁶ switching cycles with small load
TypeType 2, EN ISO 14119
Actuator codingLow coding level, EN ISO 14119
Fault detectionNo internal fault detection; switch cannot assume a safe state in a fault; connected safety-related logic performs fault detection
Series connectionWith Flexi Loop, including diagnostics
ConnectionM12 eight-pin plug connector; brass coupling nut
Contamination rating3
Switching elementSlow action
Usage categoryAC-15/DC-13, IEC 60947-5-1
Rated operating current1 A at 24 V AC; 1 A at 24 V DC
Rated insulation voltage30 V
Rated impulse withstand voltage1,500 V AC
Output typeElectromechanical contacts
Power consumption≤8 W
Short-circuit protection1 A gG
Switching voltage≥12 V DC
Switching current1 mA at 24 V DC
Solenoid supply20.4–26.4 V DC
Solenoid duty cycle100%
Housing materialGlass-fiber-reinforced thermoplastic
Mechanical life1 × 10⁶ switching cycles
IP ratingIP67, IEC 60529
Operating temperature−20 to +55 °C
Storage temperature−20 to +55 °C
Actuator supply scopeActuator is not supplied; order separately
Physical Weight (kg)0.5

Industrial Applications

1. Holding a process enclosure during a production step

A production enclosure can use the power-to-lock device to retain its closure during a process step. External control energizes the solenoid within 20.4–26.4 V DC, and the separately selected actuator is aligned for one of the four approach directions. The installation checks the required holding force against the 1,000 N FZh rating; this configuration is specified for process protection only.

Problem Solved

A commanded closure lock helps process control retain the enclosure during the selected production step, with documented holding force and separate monitoring contacts for external evaluation.

Process enclosure Power to lock Closure retention

2. Checking a closure and its locking state separately

A process machine can connect the door-monitoring and solenoid-monitoring contact functions to suitable external logic. The door contacts report the mechanical closure condition, while the separate solenoid-monitoring contact supports evaluation of the locking state. The machine uses that distinction in its process sequence, and the connected safety-related logic provides the fault detection that this switch does not perform internally.

Problem Solved

Separate contact functions help external logic distinguish a closure condition from a locking condition, providing defined inputs for process sequencing and externally implemented fault evaluation.

Door monitoring Solenoid monitoring External logic

3. Configuring a frequently cycled process hatch

A process hatch can approach the selected actuator direction and use the switch for repeated locking cycles. Mechanical design checks approach speed against 20 m/min, actuation frequency against 1,200 per hour and the stated mechanical life against the intended duty. The separately ordered actuator is positioned to avoid using the switch as a mechanical stop, while external control applies the process-protection locking sequence.

Problem Solved

Documented actuation limits help the machine builder match the locking arrangement to the hatch movement and cycle rate, with power-to-lock operation controlled by the process sequence.

Process hatch Cycle rate Actuator alignment
Select your currency