SICK 7900045 IM12-08NPS-ZC1 PNP Inductive Proximity Sensor

USD 79.04

IM12-08NPS-ZC1 provides 8 mm nominal metal sensing, non-flush M12 mounting, 1,000 Hz switching, PNP NO output and an M12 four-pin connector.

SKU SICK-7900045 Category
SICK IM Standard

SICK IM12-08NPS-ZC1 PNP Inductive Proximity Sensor

BrandSICK
Model IdentifierIM12-08NPS-ZC1
Official Part Number7900045

Technical Overview

The SICK IM12-08NPS-ZC1 is an M12 inductive proximity sensor with a PNP normally open output and DC three-wire wiring. Its electromagnetic sensing principle detects metal targets without requiring an optical path or separate reflector. The nominal sensing range is 8 mm; the actual target material, geometry and installed gap must be qualified. The non-flush mounting arrangement and M12 × 1 threaded nickel-plated brass housing define installation in the machine fixture. The sensor provides 1,000 Hz switching and operates from 10–30 V DC, with an M12 four-pin connector, a plastic sensing face and IP67 protection.

Non-flush M12 inductive sensor with 8 mm nominal range, PNP normally open output, 1,000 Hz switching and M12 four-pin connector.

Key Features

  • Inductive proximity sensing for metal targets
  • 8 mm nominal sensing range
  • Non-flush installation; M12 × 1 threaded housing
  • PNP normally open output; DC three-wire wiring
  • 1,000 Hz switching frequency
  • 10–30 V DC operation; ≤10% residual ripple
  • Continuous output current ≤200 mA
  • Nickel-plated brass housing; plastic sensing face
  • IP67; −25 to +70 °C operating range
  • M12 four-pin connector

Detect nearby metal targets without contact using non-flush M12 mounting and a PNP normally open switching signal.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing of metal targets
Housing formMetric cylindrical, standard design
Thread sizeM12 × 1
Housing diameter12 mm
Nominal sensing range Sn8 mm
Installation typeNon-flush
Switching frequency1,000 Hz
Switching outputPNP
Output functionNormally open (NO)
Electrical wiringDC 3-wire
ConnectionConnector M12, 4-pin
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤1.2 V at maximum output current
Time delay before availability≤100 ms
Hysteresis1–15%
Reproducibility≤5% of Sr at constant supply and ambient temperature
Temperature drift±10% of Sr
Continuous output current≤200 mA
Housing materialBrass, nickel-plated
Sensing face materialPlastic
Housing length65 mm
Thread length38 mm
Maximum tightening torque10 Nm
IP ratingIP67 according to EN 60529
Operating temperature−25 to +70 °C
EMCEN 60947-5-2
Shock and vibration resistance30 g, 11 ms / 10–55 Hz, 1 mm
MTTFD192 years
Diagnostic coverage DCavg0%

Industrial Applications

1. Confirming a metal part in a fixture

A machining fixture can place the sensor beside the expected location of a metal part so the target enters its qualified sensing zone when seated. Non-flush installation requires the sensing end to project beyond the surrounding mounting surface, and the PNP normally open output provides the presence signal. Actual target material and geometry must be qualified for the installed gap.

Problem Solved

A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.

Non-flush mounting PNP NO Metal presence

2. Counting metal tabs on a rotating mechanism

A rotating mechanism can present separated metal tabs to the M12 sensing face and count each normally open output transition. The 1,000 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and target material must be qualified so consecutive targets produce distinct switching events.

Problem Solved

Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.

1,000 Hz Inductive PNP NO

3. Confirming a shuttle at a transfer position

A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The M12 thread supports fixed installation, while the normally open PNP signal reports the flag state. IP67 protection and the nickel-plated brass body support exposed machine placement.

Problem Solved

A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.

M12 thread IP67 Metal flag
Select your currency