SICK 1040880 IME08-02BNSZW2S NPN Inductive Proximity Sensor

USD 28.86

IME08-02BNSZW2S provides 2 mm nominal metal sensing, flush M8 mounting, 4,000 Hz switching, NPN NO output and a 2 m PVC cable.

SKU SICK-1040880 Category
SICK IME

SICK IME08-02BNSZW2S NPN Inductive Proximity Sensor

BrandSICK
Model IdentifierIME08-02BNSZW2S
Official Part Number1040880

Technical Overview

The SICK IME08-02BNSZW2S is an M8 inductive proximity sensor with an NPN normally open output and DC three-wire connection. Its electromagnetic sensing principle detects metal targets without requiring optical access or a separate reflector. The nominal sensing range is 2 mm, with an assured sensing range of 1.62 mm; nonferrous targets require the documented material reduction factors. Flush installation and an M8 × 1 threaded nickel-plated brass housing support integration in a metal fixture. The sensor provides 4,000 Hz switching and operates from 10–30 V DC, with a 2 m three-wire PVC cable, PA66 sensing face and IP67 enclosure rating.

Flush M8 inductive sensor with 2 mm nominal range, NPN normally open output, 4,000 Hz switching and 2 m three-wire PVC cable.

Key Features

  • Inductive proximity detection of metal targets
  • 2 mm nominal sensing range; 1.62 mm assured range
  • Flush installation; M8 × 1 threaded housing
  • NPN normally open output; DC three-wire wiring
  • 4,000 Hz switching frequency
  • 10–30 V DC operation; ≤10 mA no-load current
  • Continuous output current ≤200 mA
  • Nickel-plated brass housing; PA66 sensing face
  • IP67; −25 to +75 °C operating range
  • 2 m three-wire PVC cable; two mounting nuts supplied

Detect nearby metal targets without contact using flush M8 mounting and an NPN normally open switching signal.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing of metal targets
Housing formMetric cylindrical, standard design
Thread sizeM8 × 1
Housing diameter8 mm
Nominal sensing range Sn2 mm
Assured sensing range Sa1.62 mm
Installation typeFlush
Switching frequency4,000 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC 3-wire
ConnectionCable, 3-wire, 2 m
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤2 V at maximum output current
Time delay before availability≤100 ms
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply and ambient temperature
Temperature drift±10% of Sr
Continuous output current≤200 mA
No-load current≤10 mA
Housing materialBrass, nickel-plated
Sensing face materialPA66 plastic
Housing length52 mm
Thread length34 mm
Maximum tightening torque≤5 Nm
Items supplied2 metal fastening nuts
IP ratingIP67 according to EN 60529
Operating temperature−25 to +75 °C
EMCEN 60947-5-2
Shock and vibration resistance30 g, 11 ms / 10–55 Hz, 1 mm
Reference material reduction factorsSt37 steel: 1; stainless steel V2A/304: approximately 0.8; aluminum: approximately 0.45; copper/brass: approximately 0.4; reference values may vary
MTTFD1,735 years
Diagnostic coverage DCavg0%
UL fileNRKH.E181493
Cable jacket materialPVC
Conductor cross-section0.25 mm²
Cable diameterØ3.9 mm

Industrial Applications

1. Confirming a metal part in a fixture

A machining fixture can place the sensor beside the expected location of a metal part so the target enters its assured sensing zone when seated. Flush installation allows mounting in the fixture face, and the NPN normally open output provides the presence signal. Target material must be considered using the documented reduction factors.

Problem Solved

A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.

Flush mounting NPN NO Metal presence

2. Counting metal tabs on a rotating mechanism

A rotating mechanism can present separated metal tabs to the M8 sensing face and count each normally open output transition. The 4,000 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and material reduction factors must be qualified so consecutive targets produce distinct switching events.

Problem Solved

Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.

4,000 Hz Inductive NPN NO

3. Confirming a shuttle at a transfer position

A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The M8 thread and two supplied mounting nuts support fixed installation, while the normally open NPN signal reports the flag state. IP67 protection and the nickel-plated brass body support exposed machine placement.

Problem Solved

A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.

M8 thread IP67 Metal flag
Select your currency