SICK 1091945 IME2S12-04B4DW2 Inductive Safety Switch

USD 146.90

Inductive safety switch with 4 mm steel-target range, two OSSDs, PL d/SIL 2, flush M12 housing, 2 m four-wire cable and IP67 protection.

SKU SICK-1091945 Category
SICK IME2S

SICK IME2S12-04B4DW2 Inductive Safety Switch

BrandSICK
Model IdentifierIME2S12-04B4DW2
Official Part Number1091945

Technical Overview

The SICK IME2S12-04B4DW2 is a cylindrical M12 inductive safety switch for noncontact position and area determination of metal targets. It provides two self-monitoring semiconductor safety outputs (OSSDs) with PL d, Category 2 and SIL 2 ratings. For steel FE360, the nominal sensing range is 4 mm, with a 3.2 mm assured switch-on distance and 6 mm assured switch-off distance. This flush version uses a 2 m PVC four-wire cable and requires individual wiring with diagnostics. Response and release times are each ≤1 ms. The switch operates from 24 V DC within 19.2–28.8 V and has an IP67 enclosure.

Inductive safety switch with 4 mm steel-target range, two OSSDs, PL d/SIL 2, flush M12 housing and 2 m four-wire cable.

Key Features

  • Inductive safety switch; flush installation; one active sensor surface
  • 4 mm nominal range on steel FE360; 3.2 mm assured ON and 6 mm assured OFF distances
  • Two self-monitoring OSSD safety outputs
  • PL d and Category 2 per ISO 13849-1; SIL 2 per IEC 61508
  • Response ≤1 ms; release ≤1 ms; risk time ≤20 ms
  • Actuation frequency ≤100 Hz; switch-on time 1 s
  • 24 V DC nominal; permitted supply 19.2–28.8 V; consumption ≤20 mA
  • 2 m PVC four-wire cable; individual wiring with diagnostics
  • Nickel-plated brass M12 housing and VISTAL® sensing surface
  • IP67; −25 to +70 °C operating and storage range

Monitor the position of metal machine elements without contact using two self-monitoring OSSD outputs and defined assured switch-on and switch-off distances.

Technical Specification Matrix

ParameterValue
Sensor principleInductive
Number of safe outputs2
Sensing range Sn4 mm, steel FE360
Assured switch-on distance Sao3.2 mm, steel FE360
Assured switch-off distance Sar6 mm, steel FE360
Active sensor surfaces1
Actuation frequency≤100 Hz
InstallationFlush
Safety integrity levelSIL 2, IEC 61508
Performance levelPL d, ISO 13849-1
Safety categoryCategory 2, ISO 13849-1
PFHD6.0 × 10⁻⁸ per hour at 40 °C and 1,000 m above sea level
Mission time20 years, ISO 13849-1
Switch typeType 3; uncoded actuator per EN ISO 14119
Safe state in a faultAt least one OSSD is OFF
Safe series connectionNone; individual wiring only, with diagnostics
Connection2 m four-wire cable
IndicatorsLED diagnostics and status display
Protection classIII, IEC 61140
Rated insulation voltage28.8 V
Rated impulse withstand voltage1,500 V
Power supply24 V DC nominal; 19.2–28.8 V DC permitted
Current consumption≤20 mA
Output typeSelf-monitoring semiconductor outputs (OSSDs)
Response time≤1 ms
Release time≤1 ms
Risk time≤20 ms
Switch-on time1 s
DesignCylindrical
Housing materialNickel-plated brass
Sensing surface materialVISTAL®
IP ratingIP67, IEC 60529
Operating temperature−25 to +70 °C
Storage temperature−25 to +70 °C
Relative humidity50% at 70 °C, IEC 60947-5-2
Vibration resistance10–55 Hz, 1 mm, IEC 60947-5-2
EMCIEC 60947-5-2; IEC 61000-6-7; IEC 60947-5-3
Housing threadM12 × 1
Housing length63 mm
Thread length40.9 mm
Items suppliedTwo nickel-plated brass mounting nuts
Nut width across flats17 mm
Conductor assignmentBrown: +24 V DC; white: OSSD 1; blue: 0 V DC; black: OSSD 2
Cable materialPVC
Conductor materialCopper
Cable diameter3.9 mm
Conductor cross-section0.25 mm²
Fixed-installation bend radius>6 × cable diameter
Moving-cable bend radius>10 × cable diameter

Industrial Applications

1. Checking a rotary table reference position

A rotary indexing table can present a qualified metal feature to the sensing face at the required transfer position. The two OSSDs convey the local position condition to a suitable safety control system. For steel FE360, the 3.2 mm assured switch-on and 6 mm assured switch-off distances define the guaranteed state regions used in the mechanical design.

Problem Solved

The local position signal helps the safety control system evaluate whether the table is at its designated transfer reference before permitting the associated material-handling operation.

Rotary table Two OSSDs Assured distances

2. Monitoring a metal load carrier on a transport platform

A transport platform can position a qualified metal feature on its load carrier near the inductive sensing surface. The safety controller evaluates both self-monitoring OSSDs as a local carrier-presence condition. The 4 mm nominal range applies to steel FE360, and the final target material, mounting geometry and switching distances must follow the manufacturer operating instructions.

Problem Solved

A safety-related carrier-presence input supports the controller in recognizing an absent carrier at the monitored support point before it permits the transport action defined by the machine design.

Carrier presence Inductive Safety control

3. Monitoring a metal access-cover position

A metal access cover can carry an intended actuator feature that enters the switch response region when the cover reaches its defined position. The uncoded inductive switch supplies two OSSDs to the safety control system. The installation must prevent unintended actuation by other metal objects, and the controller evaluates this local position signal within the complete protective arrangement.

Problem Solved

The cover-position signal provides the safety controller with a noncontact state input for its access-monitoring function, without requiring a mechanical plunger to touch the cover during each cycle.

Access-cover position Uncoded OSSD