SICK 1041056 IME30-20NNSZW2S NPN Inductive Proximity Sensor

USD 48.10

IME30-20NNSZW2S provides 20 mm nominal metal sensing, non-flush M30 mounting, 500 Hz switching, NPN NO output and a 2 m PVC cable.

SKU SICK-1041056 Category
SICK IME

SICK IME30-20NNSZW2S NPN Inductive Proximity Sensor

BrandSICK
Model IdentifierIME30-20NNSZW2S
Official Part Number1041056

Technical Overview

The SICK IME30-20NNSZW2S is an M30 inductive proximity sensor with an NPN normally open output and DC three-wire wiring. It detects metal targets without an optical path, with a nominal sensing range of 20 mm and an assured range of 16.2 mm. Target material must be considered using the documented reduction factors. The non-flush installation arrangement and M30 × 1.5 threaded nickel-plated brass housing support machine integration. The sensor provides 500 Hz switching and operates from 10–30 V DC, with a 2 m three-wire PVC cable, a PA66 sensing face and IP67 protection.

Non-flush M30 inductive sensor with 20 mm nominal range, NPN normally open output, 500 Hz switching and 2 m three-wire PVC cable.

Key Features

  • Inductive proximity sensing of metal targets
  • 20 mm nominal range; 16.2 mm assured range
  • Non-flush installation; M30 × 1.5 threaded housing
  • NPN normally open output; DC three-wire wiring
  • 500 Hz switching frequency
  • 10–30 V DC operation; ≤10 mA no-load current
  • Continuous output current ≤200 mA
  • Nickel-plated brass housing; PA66 sensing face
  • IP67; −25 to +75 °C operating range
  • 2 m three-wire PVC cable; two mounting nuts supplied

Detect nearby metal targets without contact using non-flush M30 mounting and an NPN normally open switching signal.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing of metal targets
Housing formMetric cylindrical, standard design
Thread sizeM30 × 1.5
Housing diameter30 mm
Nominal sensing range Sn20 mm
Assured sensing range Sa16.2 mm
Installation typeNon-flush
Switching frequency500 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC 3-wire
ConnectionCable, 3-wire, 2 m
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤2 V at maximum output current
Time delay before availability≤125 ms
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply and ambient temperature
Temperature drift±10% of Sr
Continuous output current≤200 mA
No-load current≤10 mA
Housing materialBrass, nickel-plated
Sensing face materialPA66 plastic
Housing length70 mm
Thread length41 mm
Maximum tightening torque≤100 Nm
Items supplied2 nickel-plated brass mounting nuts
IP ratingIP67 according to EN 60529
Operating temperature−25 to +75 °C
EMCEN 60947-5-2
Shock and vibration resistance30 g, 11 ms / 10–55 Hz, 1 mm
Reference material reduction factorsSt37 steel: 1; stainless steel V2A/304: approximately 0.8; aluminum: approximately 0.45; copper/brass: approximately 0.4; reference values may vary
MTTFD1,735 years
Diagnostic coverage DCavg0%
UL fileNRKH.E181493
Cable jacket materialPVC
Conductor cross-section0.25 mm²
Cable diameterØ3.9 mm

Industrial Applications

1. Confirming a metal part in a fixture

A machining fixture can place the sensor beside the expected location of a metal part so the target enters its assured sensing zone when seated. Non-flush installation requires the sensing end to project beyond the surrounding mounting surface, and the NPN normally open output provides the presence signal. Target material must be considered using the documented reduction factors.

Problem Solved

A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.

Non-flush mounting NPN NO Metal presence

2. Counting metal tabs on a rotating mechanism

A rotating mechanism can present separated metal tabs to the M30 sensing face and count each normally open output transition. The 500 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and material reduction factors must be qualified so consecutive targets produce distinct switching events.

Problem Solved

Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.

500 Hz Inductive NPN NO

3. Confirming a shuttle at a transfer position

A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The M30 thread and two supplied mounting nuts support fixed installation, while the normally open NPN signal reports the flag state. IP67 protection and the nickel-plated brass body support exposed machine placement.

Problem Solved

A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.

M30 thread IP67 Metal flag
Select your currency