SICK 1076671 IMF12-04BNSNC0S NPN Inductive Sensor

USD 52.00

M12 flush inductive sensor with 4 mm nominal range, NPN NO output, 2,000 Hz switching, stainless steel body and IP68/IP69K protection.

SKU SICK-1076671 Category
SICK IMF

SICK IMF12-04BNSNC0S Inductive Sensor

BrandSICK
Model IdentifierIMF12-04BNSNC0S
Official Part Number1076671

Technical Overview

The SICK IMF12-04BNSNC0S is an M12 flush inductive proximity sensor for hygienic and washdown zones. It provides a 4 mm nominal sensing range and 3.24 mm assured range, with a normally-open NPN output and 2,000 Hz switching. The stainless steel V4A housing uses DIN 1.4404/AISI 316L, while the sensing face is LCP plastic. Cleaning-agent resistance, IP68/IP69K protection and a −40 to +100 °C operating range support demanding machine environments. A visual adjustment indicator supports checking the target position during installation. An M12 four-pin connector with gold-plated contacts connects the DC three-wire device to a 10–30 V DC supply.

M12 flush inductive sensor with 4/3.24 mm nominal/assured ranges, NPN NO output, 2,000 Hz switching and IP68/IP69K protection.

Key Features

  • M12 metric housing; flush installation
  • 4 mm nominal range; 3.24 mm assured range
  • NPN normally-open output; DC three-wire; 2,000 Hz switching
  • V4A stainless steel housing, DIN 1.4404/AISI 316L; LCP sensing face
  • Resistant to cleaning agents; specified for hygienic and washdown zones
  • IP68 per EN 60529; IP69K per ISO 20653:2013-03
  • −40 to +100 °C ambient operation
  • 10–30 V DC; continuous output current ≤200 mA
  • M12 four-pin male connector with gold-plated contacts
  • Visual adjustment indicator; two V4A stainless steel mounting nuts supplied

Monitor metal targets in washdown machinery with a stainless steel inductive sensor, cleaning-agent resistance and a visual adjustment indicator.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical, standard design
Housing diameter12 mm
Housing threadM12 × 1
Sensing range Sn4 mm nominal
Assured sensing range Sa3.24 mm
InstallationFlush
Switching frequency2,000 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC three-wire
ConnectionM12 four-pin male connector; gold-plated contacts
Pin assignment1/BN: L+; 4/BK: NO; 3/BU: M; 2: not connected
Special featuresCleaning-agent resistance, visual adjustment indicator and temperature resistance
Specified application environmentHygienic and washdown zones; difficult application conditions
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤2 V at maximum output current Ia
Hysteresis3–20%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
EMCAccording to EN 60947-5-2
Continuous output current≤200 mA
No-load current≤10 mA
Circuit protectionShort-circuit and power-up pulse protection
Shock and vibration data100 g / 2 ms / 500 cycles; 150 g / 1 million cycles; 10–55 Hz / 1 mm; 55–500 Hz / 60 g
Operating temperature−40 to +100 °C
Housing materialStainless steel V4A, DIN 1.4404 / AISI 316L
Sensing face materialLCP plastic
Protection classIII
UL fileE181493
MTTFD1,971 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsApproximate reference values, may vary: V2A/304=0.65; aluminum=0.35; copper=0.24; brass=0.38
Mounting clearancesB=12 mm; C=12 mm; D=12 mm; F=32 mm; follow manufacturer installation diagram
IP ratingIP68 per EN 60529; IP69K per ISO 20653:2013-03
Items suppliedTwo V4A stainless steel mounting nuts
Visual adjustment indicatorInstallation aid indicating the target zone between Sr and Sa; Sa =0.81 × Sn
Housing length65 mm
Thread length48 mm

Industrial Applications

1. Confirming a metal carrier at a washdown station

A packaging station can present a qualified metal feature on a carrier near this sensor at the required transfer position. The flush installation, 4 mm nominal range and 3.24 mm assured range guide placement. The NPN normally-open signal reports the local carrier condition, while IP68/IP69K protection and cleaning-agent resistance support the specified washdown environment.

Problem Solved

A contactless carrier-position signal gives the sequence controller a reference before transfer, avoiding a mechanical feeler against the carrier at a station exposed to cleaning operations.

Washdown station Metal carrier NPN

2. Counting metal components at a guided feeder

A guided feeder can carry individual qualified metal components past the sensing face so each passage changes the normally-open output. An external counter reads these transitions. The 2,000 Hz switching frequency and 3–20% hysteresis guide target spacing and timing, while the listed target-material reduction factors must be considered when qualifying different metal components.

Problem Solved

A noncontact component-passage event supports quantity tracking at the feeder exit without a counting lever touching each part, with counting and feed decisions performed by the external controller.

Metal-part counting 2,000 Hz Material factors

3. Aligning a metal actuator during fixture setup

A fixture setup can move an intended metal actuator toward the sensing face while the installer observes the visual adjustment indicator. The manufacturer installation-aid diagram distinguishes the target region between Sr and Sa, with Sa equal to 0.81 times the nominal range. Final mounting also follows the flush-installation clearances and target-material reduction factors.

Problem Solved

The local adjustment indication helps the installer establish a repeat actuator position in the specified detection zone, reducing reliance on repeated machine cycles simply to observe an output transition.

Visual setup aid Actuator alignment Flush mounting