| Functional principle | 2D LiDAR scanning; integrated field evaluation |
| Application environment | Indoor and outdoor |
| Light source | 905 nm infrared laser |
| Laser class | 1; IEC 60825-1:2014 and EN 60825-1:2014+A11:2021 |
| Horizontal aperture | 270° |
| Scan frequency | 25 Hz / 50 Hz |
| Horizontal angular resolution | 0.25° / 0.5° |
| Working range | 0.5–20 m |
| Scanning distance by remission | 18 m at 10% remission; 20 m at 90% remission |
| Evaluated echoes | 2 |
| Fog correction | Yes |
| Heating | Yes |
| Response time | ≥20 ms |
| Systematic error | Typical ±30 mm; actual value depends on environmental conditions |
| Statistical error | Typical 12 mm; actual value depends on environmental conditions |
| Field evaluation | 10 fields; 10 simultaneous evaluation cases |
| Ethernet | TCP/IP; 10/100 Mbit/s; read-result data interface |
| Serial interface | RS-232; 9.6–115.2 kBaud; read-result data and service interface |
| CAN | Output extension |
| Inputs and outputs | Two digital inputs and two encoder inputs; three outputs |
| Ethernet connector | M12 female, four-pin, D-coded; 1 TX+, 2 RX+, 3 TX−, 4 RX− |
| DATA connector | M12 male, eight-pin, A-coded; 1 RxD HOST, 2 TxD HOST, 3 CAN_HI, 4 CAN_LO, 5 GND RS/CAN, 6 In1, 7 In2, 8 GND IN1/2 |
| I/O connector | M12 female, eight-pin, A-coded; LMS11x: 1 INC1 A, 2 INC1 B, 3 GND INC1, 4 OUT1 A, 5 OUT2 A, 6 OUT3 A, 7 OUT1–3 B, 8 OUT1–3 R |
| Power connector | M12 five-pin, A-coded; 1 Vs, 2 Vs heating, 3 GND, 4 reserved, 5 GND heating |
| Service connector | M8 female, four-pin; 1 reserved, 2 RxD AUX, 3 GND RS, 4 TxD AUX |
| Power supply | 10.8–30 V DC |
| Power consumption | Typical 8 W; heating typical 35 W |
| Indicators | Seven-segment display plus five LEDs for device status, contamination warning and initial condition |
| Mounting holes | M5 × 7.5 mm |
| Housing color | Gray, RAL 7032 |
| IP rating | IP67; EN 60529, section 14.2.7 |
| Protection class | III; EN 61010-1:2010-10 |
| Remission factor | 3% to >1,000% for reflectors |
| Ambient-light immunity | 80,000 lx |
| Operating temperature | −30 to +50 °C |
| Storage temperature | −30 to +70 °C |
| EMC | EN 61000-6-2:2005 / EN 61000-6-3:2007+A1:2011 |
| Vibration resistance | EN 60068-2-6 (1995-04) |
| Shock resistance | EN 60068-2-27 (1993-03) |
| MTBF | >100 years |
| MTTFD | >100 years |
| Use classification | The sensor is not a safety component under relevant machine-safety legislation |
| Physical Weight (kg) | 1.1 |