Contact Us:
sales@inosaki.com

LS-500 – Amplifier-separated Type Digital Laser Sensor – Panasonic Photoelectric Sensors

$ 218.50$ 231.84

Specifications

Product Number LS-501-C2
Part Number LS-501-C2
Products Name Amplifier-separated Type Digital Laser Sensor
Product details Amplifiers(Cable type)
The price of the product Please contact our office
Applicable regulations EMC Directive, RoHS Directive
Operation indicator Orange LED (lights up when sensing output 1 or sensing output 2 is ON)
Protection IP40(IEC)
Ambient temperature -10 to +55degrees + 14 to 131 degrees Fahrenheit (If 4 to 7 units are mounted close together, -10 to +50 degrees +14 to +122 degrees Fahrenheit ; if 8 to 12 units are mounted close together, -10 to +45 degrees +14 to +113 degrees Fahrenheit )(No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 1.5 mm 0.059 in double amplitude or maximum acceleration 98 m/s2 in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Material Enclosure: Polycarbonate
Cover: Polycarbonate
Switch: Polyacetal
Cable 0.2mm2 6-core cabtyre cable, 2 m 6.562 ft long
Weight Net weight: 75 g approx.
Gross weight: 110 g approx.
Accessory FX-MB1 (Amplifier protective seal): 1 set
Supply voltage 12 to 24 V DC +10-15% Ripple P-P 10 % or less
Power consumption Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,excluding monitor current output)
ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,excluding monitor current output)
Sensing outputs (Sensing output 1, 2) NPN open-collector transistor
・Maximum sink current: 50 mA (Note:25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).)
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 2 V or less (at max. sink current)
(Note:Select either sensing output 2 or external input as the connector type.)
Sensing outputs (Sensing output 1, 2):Output operation Selectable either Light-ON or Dark-ON
Sensing outputs (Sensing output 1, 2):Short-circuit protection Incorporated
Sensing output setting:Sensing output 1 Normal mode, differential mode, hysteresis mode, window comparator mode, selectable
Sensing output setting:Sensing output 2 Normal mode, differential mode, hysteresis mode, self-diagnostic output mode, answer-back output mode, selectable
(Note:Select either sensing output 2 or external input.)
Response time H-SP: 60 micro s or less, FAST: 150 micro s or less, STD: 250 micro s or less, LONG: 500 micro s or less, U-LG: 5 ms or less, HYPR: 24 ms or less selectable
Monitor current output Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication)
Response time: 2 ms or less
Zero point: 4 mA plus or minus 1 % F.S.
Span: 16 mA plus or minus 5 % F.S.
Linearity: plus or minus 3 % F.S.
Load resistance: 0 to 250 Ohm
External input NPN non-contact input
– Signal condition High: +8 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less)
– Input impedance: 10 kOhm approx.(Note:Select either sensing output 2 or external input.)
External input function Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /display adjustment / data bank load / data bank save, selectable
Laser emission indicator Green LED (lights up during laser emission)
Output select indicator Yellow LED (lights up when output is selected)
Digital display 8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO
Incident light indication range H-SP/FAST/STD: 0 to 4,000
LONG/U-LG/HYPR: 0 to 9,999
Sensitivity setting 2-level teaching / limit teaching / full auto teaching / manual adjustment
Logical operation Between sensing output 1 and calculation target: Disabled / and / or / xor, selectable
Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable
Timer function OFF-delay timer, ON-delay timer, ONE-SHOT timer, ON / OFF-delay timer, ON-delay / ONE-SHOT timer,
switchable either effective of ineffective, with variable timer period

OFF-delay timer, ON-delay timer, ONE-SHOT timer,
switchable either effective of ineffective, with variable timer period

Timer function:Time Timer range ” ms”: 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals
Timer range ” sec”: 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals
Timer range ” 1/10 ms”: 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output.
Automatic interference prevention function Incorporated
(Note:Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR)
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3mm2, or more, cable.

 

Product Number LS-H901
Part Number LS-H901
Products Name Amplifier-separated Type Digital Laser Sensor
Product details Sensor heads(Coaxial retroreflective type)
The price of the product Please contact our office
Applicable regulations EMC Directive, RoHS Directive
Applicable amplifiers LS-501(P), LS-501(P)-C2
(Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Sensing range:H-SP mode 0.01 to 1m 0.033 to 3.281 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:FAST mode 0.01 to 1m 0.033 to 3.281 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:STD mode 0.01 to 1m 0.033 to 3.281 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG mode 0.01 to 1.5m 0.033 to 4.921 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG 0.01 to 2m 0.033 to 6.562 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:HYPR 0.01 to 2.5m 0.033 to 8.202 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Spot size Approx. dia. 6 mm dia. 0.236 in or less (at a distance from the sensor head of 1 m 3.281 ft)
Sensing object Opaque, translucent, or transparent object
(Note:Make sure to confirm detection with an actual sensor before use.)
Operation indicator Orange LED (lights up when the amplifier output is ON)
Protection IP40 (IEC)
Ambient temperature -10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude or maximum acceleration 98 m/s2 in X, Y and Z directions for two hours each
Shock resistance 98 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Emitting element:Type Red semiconductor laser diode
Emitting element:Peak emission wavelength 660 nm 0.026 mil
Emitting element:Laser class Class 1 [IEC / EN / JIS / GB / KS / FDA]
(Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Emitting element:Max. output 1mW
Material Enclosure: PBT
Indicator cover: Polycarbonate
Beam-emitting / receiving surfaces: Glass
Cable 0.09 mm2 2-core two parallel shielded cables, 2 m 6.562 ft long
(Note:Cable cannot be extended.)
Weight Net weight: 50 g approx.
Gross weight: 85 g approx.
Accessory MS-LS-1(Mounting bracket): 1pc.
RF-330(Refrector): 1pc.