Contact Us:
sales@inosaki.com

LUTM-UP81162P Luminescence Sensors – SICK Sensor

$ 344.08

SKU SICK 1067295 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1067295
Luminescence Sensor Model: LUTM-UP81162P
OEM Spec Ref 

Features

Dimensions (W x H x D) 12 mm x 31.5 mm x 21 mm
Sensing distance 12.5 mm 1)
Housing design (light emission) Rectangular
Working range 8 mm … 20 mm
Light source LED, Ultraviolet light 2)
Wave length 370 nm
Light emission Long side
Light spot size 2 mm x 2.5 mm 3)
Light spot direction Vertical
Receiving range 450 nm … 750 nm
Adjustment Teach-in button
Teach-in mode 2-point teach-in static/dynamic
Output function Light/dark switching 4)
  • 1) From front edge of lens.
  • 2) Average service life: 100,000 h at TU = +25 °C.
  • 3) At sensing distance.
  • 4) L/D switching via teach-in.

Mechanics/electronics

Supply voltage 12 V DC … 24 V DC 1)
Ripple ≤ 5 Vpp 2)
Current consumption ≤ 50 mA 3)
Switching frequency 6 kHz 4)
Response time 80 µs 5)
Jitter 40 µs
Switching output PNP
Switching output (voltage) PNP: HIGH = VS– ≤ 2 V / LOW approx. 0 V
Switching mode Light/dark switching
Output current Imax. < 100 mA 6)
Input, teach-in (ET) PNP

Teach: U = 10 V … < UV

Run: U < 2 V

Connection type Cable with M12 male connector, 4-pin, 0.2 m
Protection class III
Circuit protection UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure rating IP67
Weight 70 g
Housing material Plastic, ABS
  • 1) Limit values: DC 12 V (–10 %) … DC 24 V (+20 %). Operation in short-circuit protected network max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) With light/dark ratio 1:1.
  • 5) Signal transit time with resistive load.
  • 6) At supply voltage > 24 V, Imax = 30 mA. Imax is consumption count of all Qn.