Contact Us:
sales@inosaki.com

MACX MCR-PTB – 2865625 – Power And Error Message Module – Phoenix Contact Signal Conditioners And Measuring Transducers

$ 124.30

Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.

Commercial Data

Item number 2865625
Packing unit 1 pc
Minimum order quantity 1 pc
Product key DK111Z
Catalog page Page 175 (C-5-2019)
GTIN 4046356324618
Weight per piece (including packing) 162.8 g
Weight per piece (excluding packing) 162.8 g
Customs tariff number 85437090
Country of origin DE

Product Properties

Product type Feed-in module
Product family MACX Analog

Electrical Properties

Electrical isolation
Overvoltage category II
Pollution degree 2
Electrical isolation Input/switching output
Rated insulation voltage 50 V AC/DC
Supply
Nominal supply voltage 24 V DC

Input Data

Signal
Voltage input signal 19.2 V DC … 30 V DC (24 V DC, -20 % … +25 %)
Fuse 5 A (replaceable), slow-blow 250 V AC
Polarization and surge protection Yes

Output Data

Switching: Relay
Contact switching type 1 changeover contact
Contact material Gold (Au)
Maximum switching voltage 50 V AC (2 A)
30 V DC (2 A)
50 V DC (0.22 A)
Signal
Max. current output signal 3.75 A
Output voltage Input voltage – max 0.8 V at 3.75 A

Connection Data

Connection method Screw connection
Stripping length 7 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² … 2.5 mm²
Conductor cross section flexible 0.2 mm² … 2.5 mm²
Conductor cross section AWG 24 … 14
Tightening torque 0.5 Nm … 0.6 Nm

Ex Data

Ex installation (EPL) Gc
Div. 2

Signaling

Status display 1 x red LED (error)
2x green LEDs (PWR1 and PWR2)

Dimension

Width 17.5 mm
Height 112.5 mm
Depth 113.7 mm
Depth NS 35/7,5 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material Specifications

Color gray (RAL 7042)
Flammability rating according to UL 94 V0 (Housing)
Housing material PA 6.6

Environmental and real-life conditions 

Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -40 °C … 60 °C (Any mounting position)
Ambient temperature (storage/transport) -40 °C … 80 °C
Permissible humidity (operation) 5 % … 95 % (non-condensing)
Altitude range (≤ 2000 m)
Altitude ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
Ambient temperature (operation) -40 °C … 60 °C
Rated insulation voltage 50 V AC/DC
Altitude range (≤ 3000 m)
Height range > 2000 m … 3000 m
Ambient temperature (operation) -40 °C … 54 °C
Rated insulation voltage 40 V AC/DC
Altitude range (≤ 4000 m)
Height range > 3000 m … 4000 m
Ambient temperature (operation) -40 °C … 48 °C
Rated insulation voltage 30 V AC/DC
Altitude range (≤ 5000 m)
Height range > 4000 m … 5000 m
Ambient temperature (operation) -40 °C … 42 °C
Rated insulation voltage 30 V AC/DC

Approvals

CE
Certificate CE-compliant
ATEX
Identification  II 3 G Ex ec nC IIC T4 Gc
Certificate PxCIF08ATEX2865625X
IECEx
Identification Ex ec nC IIC T4 Gc
Certificate IECEx IBE 08.0004X
CCC / China-Ex
Identification Ex ec nC IIC T4 Gc
Certificate 2021122303114198
UL, USA/Canada
Identification UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
Certificate DNV GL TAA0000AG
Shipbuilding data
Temperature B
Humidity B
Vibration A
EMC B
Enclosure Required protection according to the Rules shall be provided upon installation on board

EMC Data

Electromagnetic compatibility Conformance with EMC directive
Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.
Noise emission
Standards/regulations EN 61000-6-4
Electromagnetic HF field
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Evaluation criterion A
Fast transients (burst)
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Evaluation criterion A
Conducted interference
Designation Conducted interferences
Standards/regulations EN 61000-4-6
Evaluation criterion A

Standards And Regulations

GB Standard
Standards/regulations GB/T 3836.1
GB/T 3836.3
GB/T 3836.8

Mounting

Mounting type DIN rail mounting

Additional information

Weight 0.1628 kg
Dimensions 11.45 × 1.75 × 11.25 cm

Related Products

AFP0RAD8
Mitutoyo_Dial Indicators_2052A
Festo_Pressure valves_LRLL-1-8-QS-4_153499
Phoenix Contact_Solid-state Relays And Electromechanical Relays_RIF-1-RPT-LDP-24DC2X21
Festo_Flow sensors_SFAB-200U-WQ8-2SA-M12_565395
Omron_Temperature_Controllers_E5CC-800_E5CC-B-800_E5CC-U-800