Sale!

Festo 6211 Solenoid Valve Body, 5/2, G1/4, Separate F Coil

Original price was: USD 78.52.Current price is: USD 68.12.

Piloted poppet-seat valve with mechanical spring reset, 1000 l/min nominal flow, 2.2–8 bar operating range and detenting override; separate F coil.

SKU Festo-6211 Category
Festo Solenoid Valves

Festo MFH-5-1/4 Solenoid Valve Body

BrandFesto
Model IdentifierMFH-5-1/4
Official Part Number6211

Technical Overview

The Festo MFH-5-1/4 is a piloted, single-solenoid 5/2-way valve body with a poppet-seat design and mechanical spring reset. All five pneumatic ports use G1/4 connections, with 1000 l/min standard nominal flow across a 2.2–8 bar operating range. The F solenoid coil is ordered separately, so voltage and power depend on the selected coil. Detenting manual override and throttleable exhaust support circuit setup, with component switching times of 9 ms on and 29 ms off. The 290 g die-cast aluminium body has NBR seals, an M5 pilot-exhaust port and manifold-rail or through-hole mounting.

G1/4 single-solenoid 5/2 valve body with mechanical spring reset, 1000 l/min nominal flow and separately ordered F coil.

Key Features

  • Single-solenoid 5/2-way poppet-seat function
  • Piloted actuation with mechanical spring reset
  • G1/4 connections at ports 1, 2, 3, 4 and 5
  • 1000 l/min standard nominal flow to DIN 1343
  • F solenoid coil and its electrical connection ordered separately
  • 2.2–8 bar operating range and non-reversible flow direction
  • 9 ms switch-on and 29 ms switch-off times
  • Detenting manual override and throttleable exhaust
  • 30.5 mm construction width, 32 mm mounting grid pitch and M5 pilot exhaust port 84
  • 290 g die-cast aluminium body with NBR seals; manifold-rail or through-hole mounting

Control a double-acting pneumatic circuit with G1/4 ports and 1000 l/min nominal flow, using mechanical spring reset and a separately selected F coil.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, single solenoid
Type of actuationElectrical
Construction width30.5 mm
Nominal flow rate standardised according to ISO 87781000 l/min
Standard nominal flow rate (standardised to DIN 1343)1000 l/min
pneumatic working portG1/4
Operating voltageVia solenoid coil, must be ordered separately
Operating pressure0.22 MPa...0.8 MPa; 2.2 bar...8 bar
DesignPoppet seat
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65
Nominal size7 mm
Mounting grid pitch32 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting
Type of pilotingPiloted
Flow directionNon-reversible
lapUnderlap
b value0.19
C value4.49 l/sbar
Switching time off29 ms
Switching time on9 ms
Max. positive test pulse with 0 signal2200 µs
Max. negative test pulse with 1 signal3700 µs
Characteristic coil dataSee solenoid coil, to be ordered separately
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...60 °C
Media temperature-10 °C...60 °C
Ambient temperature-5 °C...40 °C
Physical Weight (kg)0.29
Electrical connectionVia F coil, to be ordered separately
Type of mountingEither:; On manifold rail; With through-hole
Pilot exhaust port 84M5
Pneumatic connection, port 1G1/4
Pneumatic connection, port 2G1/4
Pneumatic connection, port 3G1/4
Pneumatic connection, port 4G1/4
Pneumatic connection, port 5G1/4
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Double-Acting Cylinder Direction Control

A transfer fixture needs to alternate pressure and exhaust between the two chambers of a double-acting cylinder. The valve's single-solenoid 5/2 function provides the two routing states, with mechanical spring reset. G1/4 connections and 1000 l/min standard nominal flow define the pneumatic interface, while a separately ordered F coil establishes the electrical actuation configuration.

Problem Solved

The five-port routing function supplies the cylinder's directional pressure and exhaust paths, combining an electrical command and mechanical spring reset for the fixture's pneumatic sequence.

5/2 single solenoid Mechanical spring reset G1/4 ports

2. Exhaust-Flow Setup for a Pneumatic Mechanism

A pneumatic mechanism needs its exhaust path arranged to suit the intended motion behaviour. Festo specifies that this valve's exhaust can be throttled, allowing appropriate external flow-control components in the surrounding circuit. The 2.2–8 bar working range and non-reversible flow direction define the valve conditions, while the actuator load and installed restriction determine the resulting motion.

Problem Solved

Throttleable exhaust permits flow-control elements to shape the connected mechanism's exhaust behaviour, providing a defined routing component for tuning the pneumatic motion in its intended flow direction.

Throttleable exhaust 2.2–8 bar Non-reversible flow

3. Local Routing Checks during Commissioning

During machine commissioning, a technician needs to exercise the valve's pneumatic routing at the component before completing the sequence setup. The detenting manual override provides local actuation, while manifold-rail or through-hole mounting locates the body in the assembly. Separate 9 ms on and 29 ms off specifications characterise component switching for the subsequent electrical sequence.

Problem Solved

A local manual override lets the technician exercise the valve routing during setup, while the documented mounting and switching data support integration into the machine's pneumatic sequence.

Detenting override 9 ms on / 29 ms off Manifold or through-hole
Select your currency