SICK 1050765 MM18-70APS-VCK PNP Magnetic Proximity Sensor

USD 28.60

MM18-70APS-VCK provides axial magnetic detection, a PNP NO output, 5,000 Hz switching and an M12 four-pin connector in an IP67 threaded metal housing.

SKU SICK-1050765 Category

Out of stock

SICK MME

SICK MM18-70APS-VCK PNP Magnetic Proximity Sensor

BrandSICK
Model IdentifierMM18-70APS-VCK
Official Part Number1050765

Technical Overview

The SICK MM18-70APS-VCK is a magnetic proximity sensor with an M18 × 1 threaded housing and a PNP normally open output. It responds to an axially aligned magnet, providing a discrete signal without mechanical contact with the moving target. The specified 0–70 mm sensing range uses a MAG-3010-B magnet in nonmagnetic mounting material; other magnets and surrounding materials require application qualification. Magnetic sensitivity is 0.7 mT, and switching frequency is 5,000 Hz. The sensor operates from 10–30 V DC, connects through an M12 four-pin male connector and uses a V4A stainless steel housing rated IP67. Two mounting nuts support installation.

Axial magnetic proximity sensor with PNP NO output, 0–70 mm reference-magnet sensing, 5,000 Hz switching, M12 four-pin connector and IP67 housing.

Key Features

  • Axial magnetic proximity detection
  • M18 × 1 threaded V4A stainless steel housing
  • 0–70 mm range with MAG-3010-B in nonmagnetic mounting material
  • 0.7 mT magnetic sensitivity
  • PNP normally open output; DC three-wire operation
  • 5,000 Hz switching frequency
  • 10–30 V DC supply; maximum output current 200 mA
  • M12 four-pin male connector
  • IP67 according to EN 60529; LED indication
  • Reverse-polarity, pulsed short-circuit and power-up pulse protection

Detect an axially aligned magnet without contact and provide a PNP normally open signal from an M18 × 1 threaded, IP67 metal housing.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic proximity sensing
Housing designMetric threaded housing
Thread sizeM18 × 1
Housing diameter18 mm
Sensing range0–70 mm with MAG-3010-B (M4.0) magnet in nonmagnetic mounting material
Assured sensing distance56.7 mm
Magnetic sensitivity0.7 mT
Magnetic alignmentAxial
Switching outputPNP
Output functionNormally open (NO)
Electrical wiringDC, 3-wire
Switching frequency5,000 Hz
Power supply10–30 V DC
Residual ripple≤10% of supply voltage
Voltage drop≤2 V at maximum output current
Current consumption10 mA without load
Initialization time≤20 ms
Hysteresis1–10% of sensing range
Reproducibility≤1% of sensing range at constant supply voltage and ambient temperature
Temperature drift±10% of sensing range
Output current≤200 mA
Reverse-polarity protectionYes
Short-circuit protectionYes, pulsed
Power-up pulse suppressionYes
ConnectionM12 four-pin male connector
Pin assignment1/BN: L+; 4/BK: NO; 3/BU: M; 2/WH: not connected
IndicatorDisplay LED
Housing materialV4A stainless steel
Overall rigid length50 mm including connector
Thread length32 mm
Maximum tightening torque40 Nm
Items suppliedTwo V2A stainless-steel mounting nuts
IP ratingIP67 according to EN 60529
Operating temperature−40 to +75 °C; temperature changes below −25 °C reduce sensor service life
Shock resistance30 g for 11 ms
Vibration resistance10–55 Hz at 1 mm amplitude
EMCEN 60947-5-2
MTTFD1,980 years
Diagnostic coverage DCavg0%
Mission time20 years

Industrial Applications

1. Confirming a carriage has reached its home position

A translating carriage can carry a fixed magnet that approaches the sensing face with its magnetic axis aligned to the sensor. At the qualified home position, the PNP normally open output changes state for a compatible controller. The specified reference-magnet sensing range and 0.7 mT sensitivity guide the magnet selection and installed gap.

Problem Solved

A discrete home-position event gives the machine controller a reference for movement sequencing, helping identify when the carriage reaches the monitored position without a contact limit-switch actuator.

Carriage homing PNP NO Axial magnet

2. Counting revolutions from a magnet on a wheel

A rotating wheel can carry an appropriately oriented magnet past the sensor once per revolution. Each qualified magnetic passage produces a PNP normally open switching event for the controller to count. The 5,000 Hz switching specification, actual magnetic pulse width and controller input rate determine the usable rotation speed during commissioning.

Problem Solved

A once-per-revolution event lets the controller count turns or derive a speed indication from pulse timing, supporting motion monitoring without a mechanical contact riding on the wheel.

Revolution counting 5,000 Hz PNP output

3. Checking that a removable tool carrier is seated

A removable tool carrier can incorporate a magnet positioned to align with the sensor when the carrier reaches its seating location. The threaded housing provides an adjustable mounting position, while the PNP normally open output supplies the local presence signal. The actual magnet, gap and surrounding fixture material are qualified against the documented magnetic sensing conditions.

Problem Solved

A seated-carrier indication helps the controller identify an absent or displaced tooling carrier before a process cycle, using a magnetic target that requires no physical switch contact.

Tool-carrier presence Threaded mounting Magnetic target
Select your currency