Sale!

Festo 159700 5/2-Way ISO Valve Body, Size 2, Internal Pilot

Original price was: USD 162.76.Current price is: USD 140.40.

ISO 5599-1 size 2 valve body with pneumatic spring reset, 2300 l/min nominal flow and 2–10 bar operation; N1 solenoid coil ordered separately.

SKU Festo-159700 Category
Festo Solenoid Valves

Festo MN1H-5/2-D-2-C ISO Solenoid Valve Body

BrandFesto
Model IdentifierMN1H-5/2-D-2-C
Official Part Number159700

Technical Overview

The Festo MN1H-5/2-D-2-C is a 5/2-way single-solenoid valve body with pneumatic spring reset and an ISO 5599-1 size 2 sub-base interface. Its N1 solenoid coil is ordered separately, so the body does not define an operating voltage. Internal pilot air supports operation from 2 to 10 bar, with non-reversible flow and 2300 l/min standard nominal flow. The 54 mm-wide body has a 56 mm mounting grid pitch, 46 ms switch-on and 69 ms switch-off times. Sub-base or through-hole mounting accommodates installation, while throttleable exhaust and a non-detenting manual override support pneumatic setup.

ISO 5599-1 size 2 5/2-way valve body with pneumatic spring reset, internal pilot air and 2300 l/min nominal flow; N1 coil ordered separately.

Key Features

  • 5/2-way single-solenoid function with pneumatic spring reset
  • ISO 5599-1 size 2 sub-base interface; ISO code 251
  • N1 coil ordered separately; operating voltage depends on coil selection
  • 2300 l/min standard nominal flow rate to DIN 1343
  • 2–10 bar operating pressure with internal pilot air
  • Non-reversible flow; not suitable for vacuum
  • 54 mm construction width and 56 mm mounting grid pitch
  • 46 ms switch-on and 69 ms switch-off times
  • Throttleable exhaust; non-detenting manual override and detenting via accessory
  • 710 g die-cast aluminium body with HNBR/NBR seals

Route 2300 l/min nominal flow through an ISO size 2 cylinder-control valve, with internal piloting and pneumatic spring reset.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, single solenoid
Type of actuationElectrical
Construction width54 mm
Standard nominal flow rate (standardised to DIN 1343)2300 l/min
pneumatic working portSub-base size 2 to ISO 5599-1; G3/8
Operating voltageDefined by separately selected solenoid coil; coil not included
Operating pressure0.2 MPa...1 MPa; 2 bar...10 bar
DesignPiston gate valve
Type of resetPneumatic spring
Approvalc UL us - Recognised (Oil)
Maritime classificationSee certificate
Certificate issuing authorityDNV-TAA000032X; UL MH19482
Degree of protectionIP65
Nominal size11.5 mm
Mounting grid pitch56 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Conforms to standardISO 5599-1
Manual overrideDetenting via accessory; Non-detenting
ISO code251
Type of pilotingPiloted
Pilot air supplyInternal
Flow directionNon-reversible
lapOverlap
Suitability for vacuumNo
Switching time off69 ms
Switching time on46 ms
Max. positive test pulse with 0 signal3700 µs
Max. negative test pulse with 1 signal4600 µs
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-5 °C...50 °C
Sound pressure level85 dB(A)
Ambient temperature-5 °C...50 °C
Physical Weight (kg)0.71
Electrical connectionVia separately selected N1 coil; coil not included
Type of mountingOn sub-base; Via through-hole and screw
Pilot exhaust port 84M5
Pneumatic connection, port 1Sub-base size 2 to ISO 5599-1
Pneumatic connection, port 2Sub-base size 2 to ISO 5599-1
Pneumatic connection, port 3Sub-base size 2 to ISO 5599-1
Pneumatic connection, port 4Sub-base size 2 to ISO 5599-1
Pneumatic connection, port 5Sub-base size 2 to ISO 5599-1
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingDie-cast aluminium

Industrial Applications

1. ISO-Format Cylinder Directional Control

An assembly machine uses a double-acting cylinder that needs electrical directional control and a pneumatic-spring reset state. This 5/2-way body routes air on an ISO 5599-1 size 2 sub-base, with 2300 l/min standard nominal flow. A separately selected N1 coil supplies electrical actuation, while the internally piloted valve operates within its specified 2–10 bar range.

Problem Solved

The five-port valve routes pressure and exhaust between the cylinder chambers and provides pneumatic spring reset, combining directional actuation with a defined reset mechanism for the machine circuit.

5/2-way ISO size 2 2300 l/min nominal

2. Cylinder Motion Setup with Exhaust Throttling

A pneumatic transfer mechanism requires exhaust-flow adjustment while its cylinder movement is being set up. Festo specifies that this valve body's exhaust air can be throttled, allowing suitable external flow-control components to meter the exhausting side of the circuit. Its non-detenting manual override also permits local valve actuation during pneumatic setup without requiring the normal electrical command.

Problem Solved

Throttleable exhaust supports metering the cylinder exhaust path, while the local manual override gives the installer a direct actuation method during setup of the pneumatic mechanism.

Throttleable exhaust Non-detenting override Internal pilot

3. Standardized Sub-Base Valve-Station Installation

A machine builder organises directional valves around ISO size 2 sub-base interfaces. The body conforms to ISO 5599-1 and has a 54 mm construction width with a 56 mm grid pitch, providing defined installation data for the station. Its separate N1 coil arrangement permits electrical actuation selection alongside the station wiring requirements without changing the valve-body identity.

Problem Solved

Standardized mounting and a separately selected coil separate the pneumatic interface from the electrical selection, supporting a valve-station design with explicit connection and spacing requirements.

ISO 5599-1 56 mm grid pitch Separate N1 coil