1. Sequencing a short-stroke transfer at two positions
A short-stroke transfer cylinder can use two taught piston positions within the 0–50 mm detection zone. The two PNP normally-open outputs provide separate arrival conditions to external sequence control. After both positions are taught with the supplied tool, the controller checks the corresponding switching input before commanding the next transfer movement.
Problem Solved
Two local arrival conditions let the sequence controller distinguish the taught transfer positions using one sensor, reducing the need to allocate two separate sensing housings along the cylinder slot.
Two positions
PNP outputs
T-slot
2. Timing movement between taught positions externally
A machine controller can timestamp the switching events from Q1 and Q2 as the cylinder piston moves between the taught positions. The sensor supplies separate magnetic position events, while the controller calculates the elapsed interval and compares it with the configured process threshold. The documented reproducibility applies with supply voltage and ambient temperature constant.
Problem Solved
An event-to-event interval helps external control identify motion that takes longer than its configured process limit, using detected piston positions rather than assuming completion after a fixed delay.
External timing
Q1/Q2
Repeatability
3. Recording completed cylinder cycles externally
External machine logic can qualify the expected sequence of Q1 and Q2 switching events and record one completed cycle when the piston returns to the taught reference position. The sensor provides two local magnetic switching conditions within its detection zone. Counting, direction interpretation and rejection of repeated events are performed by the connected controller.
Problem Solved
A qualified two-position sequence supports production or maintenance cycle records and helps the external counter distinguish a completed return cycle from repeated events at a single position.
Cycle records
Two-point sequence
External counter