SICK 1044469 MZT8-03VPS-KU0 PNP NO Cylinder Sensor

USD 67.34

T-slot cylinder sensor with PNP NO output, 1,000 Hz switching, typical 3 mm overrun, 10–30 V DC supply, 2 m PUR cable and IP68/IP69K protection.

SKU SICK-1044469 Category
SICK MZT8

SICK MZT8-03VPS-KU0 PNP Magnetic Cylinder Sensor

BrandSICK
Model IdentifierMZT8-03VPS-KU0
Official Part Number1044469

Technical Overview

The SICK MZT8-03VPS-KU0 is a PNP normally-open magnetic cylinder sensor with a 24 mm housing for direct T-slot mounting. It detects a compatible piston magnet with typical response sensitivity of 2.6 mT and a typical 3 mm overrun distance. The sensor operates from 10–30 V DC with a listed continuous-current limit of 200 mA, 1,000 Hz switching frequency and 25 ms delay before availability. Its axial 2 m PUR cable has three conductors with ferrules and supports drag-chain use under documented motion conditions. PA12 housing provides IP68/IP69K protection, output-state indication, reverse-polarity protection, short-circuit protection and power-up pulse protection.

PNP NO magnetic T-slot cylinder sensor with a 24 mm housing, typical 3 mm overrun and a 2 m PUR cable with three ferruled conductors.

Key Features

  • PNP normally-open output; DC three-wire circuit
  • Direct T-slot mounting; 24 mm housing length
  • 1,000 Hz switching; 25 ms delay before availability
  • 10–30 V DC supply; continuous current≤200 mA
  • Typical sensitivity2.6 mT; typical overrun distance3 mm
  • Typical hysteresis0.7 mT; reproducibility≤0.1 mT at constant supply and temperature
  • Axial2 m PUR cable; three conductors with ferrules
  • Drag-chain cycles>2 million under documented motion conditions
  • PA12 housing; IP68/IP69K; −30 to+80 °C operation
  • Output LED; reverse-polarity, short-circuit and power-up pulse protection

Detect a compatible piston magnet through a short 3 mm typical overrun zone using a 24 mm T-slot sensor and local PNP normally-open output.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic cylinder-piston detection
Cylinder typeT-slot; direct mounting
Cylinder types with adapterProfile, tie rod, round body, dovetail groove; SMC rail CDQ2/ECDQ2; suitable adapters required
Housing length24 mm
Switching outputPNP
Output functionNO; normally open
Electrical wiringDC three-wire
Switching frequency1,000 Hz
Power supply10–30 V DC
No-load current10 mA
Voltage drop≤2.2 V
Continuous current≤200 mA
Protection classIII
Delay before availability25 ms
Response sensitivityTypical2.6 mT
Overrun distanceTypical3 mm; magnet travel while switching signal is output
HysteresisTypical0.7 mT
Reproducibility≤0.1 mT with supply voltage and ambient temperature constant
Reverse-polarity protectionProvided
Short-circuit protectionProvided
Power-up pulse protectionProvided
Status indicatorLED
Teach-inNot provided
Operating temperature−30 to+80 °C
Shock resistance30 g,11 ms
Vibration resistance10–55 Hz,1 mm
EMCEN60947-5-2
Connection2 m PUR cable; three conductors with ferrules; drag-chain use
Conductor cross-section0.14 mm²
Cable diameter2.9 mm
Bending radiusFixed installation>3×cable diameter;flexible use>5×cable diameter
Torsion specification±180° per1 m
Drag-chain cycles>2,000,000
Drag-chain test conditionsSpeed≤3.3 m/s at5 m horizontal travel; acceleration≤5 m/s²
Cable outletAxial
Housing materialPlastic; PA12
Cable materialPUR
Conductor functionsBN=L+;BU=M;BK=NO output;CD-001
IP ratingIP68 per EN60529; IP69K per DIN40050
Mounting screwSW2.0; typical tightening torque0.4 Nm
UL fileNRKH.E181493 and NRKH7.E181493
MTTFD2,289 years
Diagnostic coverage DCavg0%
Mission time20 years

Industrial Applications

1. Confirming cylinder arrival before a transfer step

A material-transfer cylinder can carry its compatible piston magnet past a sensor fixed at a defined T-slot position. The PNP normally-open output gives the external sequence controller a local arrival condition before advancing the next mechanism. The status LED provides local indication, and the controller qualifies the event within the documented switching and current limits.

Problem Solved

A local magnetic arrival condition gives external sequence control a piston-position reference without a mechanical sensing lever contacting the moving cylinder rod during repeated transfer operations.

Cylinder arrival T-slot PNP NO

2. Measuring cylinder travel time with external control

A controller can timestamp its cylinder-move command and the sensor switching event at the monitored destination to calculate an external travel-time interval. The sensor supplies the local magnetic arrival signal;it does not calculate elapsed time. Repeatability under constant supply and ambient temperature provides a documented reference for comparing repeated arrival events.

Problem Solved

Command-to-arrival timing lets external control identify a stroke that arrives later than its configured process limit,supporting machine diagnostics through a repeatable local switching event rather than a fixed wait alone.

External travel timing Arrival event Repeatability

3. Counting completed cylinder cycles

A handling cylinder can produce one qualified magnetic arrival event at the monitored stroke position for each completed cycle. Compatible external counting equipment accumulates the PNP switching transitions and filters repeated events according to machine logic. The1,000 Hz switching frequency and documented overrun behavior provide timing references when selecting cylinder speed and event qualification.

Problem Solved

A qualified piston-arrival event supports external cycle counting for throughput or maintenance records,without a mechanical counting contact against the rod or an assumed elapsed-time estimate of completed motion.

Cycle counting 1,000 Hz External counter
Select your currency