SICK 6050497 OD1-B015H05U14 0–10 V Laser Displacement Sensor

SICK 6050497 OD1-B015H05U14 0–10 V Laser Displacement Sensor

USD 1,824.68

10–20 mm laser displacement sensor with 0–10 V output, external teach input, M8 four-pin connector, four-digit display, stainless housing and IP67.

SKU: SICK-6050497 Category:
Laser Distance Sensors - SICK OD Mini

SICK OD1-B015H05U14 Analog Laser Displacement Sensor

BrandSICK
Model IdentifierOD1-B015H05U14
Official Part Number6050497

Technical Overview

The SICK OD1-B015H05U14 measures displacement over 10–20 mm using a 655 nm class 1 red laser and supplies a 0–10 V analog signal. Repeatability is 1 µm at 512 averages and constant ambient conditions; linearity is ±10 µm on a 90% remission white ceramic target. Averaging from 1–512 measurements and automatic or manual sensitivity adjustment adapt the measurement. The multifunctional input supports laser-off, external teach-in or triggering. A four-digit display and four buttons provide local setup. The stainless-steel IP67 housing connects through an M8 four-pin male connector and operates from 12 V DC−5% to 24 V DC+10%, with warm-up time up to five minutes.

10–20 mm class 1 laser displacement sensor with 0–10 V analog output, M8 four-pin male connector and IP67 stainless-steel housing.

Key Features

  • 10–20 mm displacement measuring range
  • One 0–10 V analog output;13.4-bit output resolution
  • Analog output and multifunctional input through M8 four-pin connector
  • Repeatability1 µm at512 averages and constant ambient conditions
  • Linearity±10 µm on90%remission white ceramic
  • 655 nm class1 red laser;maximum optical output390 µW
  • Averaging1–512;automatic or manual sensitivity adjustment
  • Analog-output teach;MF laser-off,external teach or trigger
  • Four-digit display and four buttons;warm-up≤5 min
  • IP67 stainless-steel housing;M8 four-pin male connector

Provide external control with a 0–10 V displacement signal over 10–20 mm, with configurable averaging and local teach-in.

Technical Specification Matrix

ParameterValue
Measuring range10–20 mm
Light sourceVisible red laser
Wavelength655 nm
Laser class1;IEC60825-1:2014 and EN60825-1:2014
Maximum optical output390 µW
Laser handlingDo not intentionally look into the beam or point it at eyes
Response time≥2 ms with fixed sensitivity and averaging1;automatic sensitivity:2–7.5 ms at500 µs measuring rate,4–15 ms at1,000 µs rate
Measuring frequency≤2 kHz
Output time≥0.5 ms
Averaging1–512 measurements
SensitivityAutomatic or manual adjustment
Multifunctional input1;laser-off,external teach-in,trigger or deactivated
Power supply12 V DC−5% to24 V DC+10%
Warm-up time≤5 min
DisplayFour-digit seven-segment display plus four status LEDs
ControlsFour buttons
Protection classIII
ConnectionM8 four-pin male connector
Housing materialStainless steel
Window materialPPSU plastic
IP ratingIP67
Operating temperature−10 to+50 °C
Storage temperature−20 to+60 °C
Relative humidity35–95%;non-condensing
Temperature drift±0.08%FS/K;FS=full sensor measuring range
Ambient light immunityTypical artificial light≤3,000 lx;sunlight≤10,000 lx
Vibration resistance10–55 Hz,1.5 mm amplitude;X/Y/Z axes2 hours each
Shock resistance50 g;X/Y/Z axes3 times each
Paint-wetting compatibilityNot free of paint-wetting impairment substances
MTTFD101 years
Diagnostic coverage DCavg0%
Physical Weight (kg)0.07
Repeatability1 µm;averaging512;constant ambient conditions
Linearity±10 µm on90%remission white ceramic
Light spot sizeTypical 700 × 500 µm at 15 mm
Analog output1 × 0–10 V;load>10,000 Ω
Analog-output resolution13.4 bit
Analog adjustmentOutput teach-in
Pin assignment1/BN=L+;2/WH=analog QA;3/BU=0 V;4/BK=MF

Industrial Applications

1. Checking part seating height in a fixture

A fixture can present the measured surface within the 10–20 mm range and read the 0–10 V output through an external analog input. After teaching the useful output span, the controller compares the measured value with its seating-height window. Warm-up, target reflectivity and averaging are included in the setup so the published repeatability conditions are distinguished from the production measurement.

Problem Solved

A continuous displacement signal lets external control evaluate how far a part sits from its expected position, providing more information than a single arrival condition.

Analog displacement External height window Teach-in

2. Recording radial runout with external analysis

A rotating component can pass its accessible surface beneath the laser while an external recorder samples the 0–10 V signal over time. The recorder derives the cyclic displacement variation from that trace within the sensor range. Measuring frequency, output time, response and selected averaging constrain the usable motion speed; the static512-average repeatability is not treated as a dynamic guarantee.

Problem Solved

A recorded displacement trace allows external analysis to distinguish cyclic surface variation from a steady mounting offset, supporting runout investigation without adding a contact probe.

External runout analysis Analog trace Configurable averaging

3. Tracking stacked-part height for replenishment

A feeder can aim the laser at the top of a stack located inside the 10–20 mm measuring range and monitor its 0–10 V signal as parts are consumed. External logic converts the measured distance to its calibrated stack-height reference and requests replenishment at a chosen threshold. Sensitivity adjustment and averaging are selected for the actual top-surface condition.

Problem Solved

A continuous distance signal supports an external replenishment threshold while also showing the remaining stack-height trend between full and nearly empty conditions.

Stack-height trend Analog signal External replenishment