SICK 6035976 OD5-25W01 RS-422 Glass Thickness Head

USD 5,129.54

24–26 mm laser head with 0.3–2 mm transparent-material thickness range, RS-422, 650 nm class 1 laser, 0.5 m Hirose cable and IP67.

SKU SICK-6035976 Category
Laser Distance Sensors - SICK OD Precision

SICK OD5-25W01 RS-422 Laser Displacement Head

BrandSICK
Model IdentifierOD5-25W01
Official Part Number6035976

Technical Overview

The SICK OD5-25W01 is an OD Precision laser displacement head covering 24–26 mm at default settings on 6–90% remission targets. Its supported transparent-material thickness range is 0.3–2 mm. Repeatability is 0.02 µm and linearity is ±1.6 µm on a mirror with 4,096 averages and constant ambient conditions. The red laser is class 1 at 650 nm, with a typical 100 ×700 µm at25 mm spot. Averaging from 1–4,096 measurements and automatic or manual sensitivity adjustment support setup. Direct RS-422 provides stand-alone communication; optional process outputs and a four-inch display require a separate AOD5 evaluation unit. The IP67 aluminum head has a glass window, distance and laser LEDs, and a 0.5 m Hirose 12-pin connector cable.

RS-422 laser displacement head with 24–26 mm measuring range, 0.3–2 mm transparent-material thickness function and a 0.5 m Hirose 12-pin cable.

Key Features

  • 24–26 mm measuring range at default settings on6–90%remission
  • Transparent-material thickness function:0.3–2 mm
  • 650 nm class1 laser;maximum390 µW
  • Typical light spot:100 ×700 µm at25 mm
  • Repeatability0.02 µm and linearity±1.6 µm on a mirror,4,096 averages,constant ambient
  • Averaging1–4,096;automatic or manual sensitivity
  • Selectable automatic measuring rate or0.1–3.2 ms sampling period
  • Direct RS-422;optional outputs/display through separate AOD5 only
  • Mirror-reference accuracy requires4,096 averages and constant ambient
  • IP67 aluminum head,glass window and0.5 m Hirose12-pin cable

Evaluate transparent-material thickness over 0.3–2 mm in a configured OD Precision setup, with direct RS-422 communication or a separate AOD5 evaluation unit.

Technical Specification Matrix

ParameterValue
System partLaser displacement sensor head
Measuring range24–26 mm;6–90%remission at default settings
Repeatability0.02 µm;mirror target,4,096 averages,constant ambient conditions
Linearity±1.6 µm;mirror target,4,096 averages,constant ambient conditions
Light sourceVisible red laser
Wavelength650 nm
Laser class1;IEC60825-1:2014 and EN60825-1:2014
Maximum optical output390 µW
Laser handlingDo not intentionally look into the beam or point it at eyes
Light spot sizeTypical 100 ×700 µm at25 mm
Response time≥0.1 ms;default sampling period0.1 ms;automatic sensitivity adjustment requires20 sampling periods
Automatic sensitivity adjustmentSampling period×20;≤2 ms at default100 µs period
Measuring frequency≤10 kHz;6–90%remission at default settings
Output time≥0.1 ms
Serial interfaceRS-422;stand-alone operation supported
Optional evaluation unitSeparate AOD5-P/N1
Optional RS-232Available through separate AOD5 only
Optional digital outputs5 PNP/NPN outputs through separate AOD5 only;maximum output current≤100 mA
Optional analog outputsThrough separate AOD5 only;up to three current and three voltage outputs
Optional current-output range4–20 mA;load≤300 Ω;through separate AOD5 only
Optional voltage-output range0–10 V;output resistance100 Ω;minimum load10 kΩ;through separate AOD5 only
Laser-off inputOne;pin12/WH
Synchronization connectionPin11/GY,Syncro
Power supply12 V DC−5% to24 V DC+10%
Warm-up time≤5 min
Head indicatorsDistance LED and laser-on LED
Optional display4-inch color display on separate evaluation unit
Protection classIII
Connection0.5 m cable with Hirose12-pin male connector
Cable diameter7.1 mm
Pin assignment1=not assigned;2/BK=RX+;3/OR=RX−;4/BU=M;5/BN=L+;6/RD=TX+;7/YE=TX−;8=not assigned;9/BK=shield;10=not assigned;11/GY=Syncro;12/WH=laser off
Housing materialAluminum
Window materialGlass
IP ratingIP67
Operating temperature−10 to+50 °C
Storage temperature−20 to+60 °C
Relative humidity35–85%;non-condensing
Temperature drift±0.01%FS/K;FS=full sensor measuring range
Ambient light immunityTypical artificial light≤3,000 lx;sunlight≤10,000 lx
Vibration resistance10–55 Hz,1.5 mm amplitude;X/Y/Z axes2 hours each
Shock resistance50 g;X/Y/Z axes3 times each
MTTFD101 years
Diagnostic coverage DCavg0%
Physical Weight (kg)0.25
Transparent-material thickness0.3–2 mm
Averaging1–4,096 measurements
Sensitivity adjustmentAutomatic or manual
Measuring-rate selectionAutomatic or selectable sampling period0.1–3.2 ms

Industrial Applications

1. Checking transparent-sheet thickness

A configured OD Precision measurement setup can use the head’s transparent-material thickness function to inspect a sheet within the specified 0.3–2 mm interval. The measurement is compared with an application-specific nominal band, using the configured system interface for process evaluation. Actual material, alignment, warm-up and averaging are established during setup; the reference-target displacement repeatability is not treated as glass-thickness accuracy.

Problem Solved

A supported thickness measurement supplies external evaluation with a numerical sheet condition, helping distinguish dimensional variation from a simple presence signal in transparent-material handling.

Transparent material 0.3–2 mm Thickness evaluation

2. Monitoring a reflective stage reference

A positioning fixture can present its reference surface inside 24–26 mm with the mirror aligned to the head optics. An RS-422 host reads displacement and compares the stationary position with a calibrated reference. The selected optical alignment and ambient conditions are established before evaluating small position changes; averaging is chosen for the application rather than assuming an unqualified precision figure.

Problem Solved

A numerical reference-surface measurement lets external control check a stationary stage position and retain its deviation from a calibrated target without contacting the moving fixture.

Reflective reference RS-422 External position comparison

3. Recording surface vibration for external analysis

An external recorder can collect RS-422 distance values from a suitably aligned surface and relate the trace to elapsed time. Changes in that trace support analysis of periodic displacement. Sampling period, sensitivity-adjustment time, averaging and serial transfer settings determine the usable vibration conditions; the highly averaged static repeatability is not used as a guarantee for a moving target.

Problem Solved

A time-based displacement trace helps external analysis distinguish periodic movement from a steady position offset, supporting investigation of vibration in a fixture or moving assembly.

RS-422 trace External vibration analysis Sampling conditions