Sale!

Festo 8049051 Vacuum Generator, 21 l/min, 0–10 V Pressure Output

Original price was: USD 158.34.Current price is: USD 136.50.

High-vacuum ejector with 21 l/min maximum suction flow, 92% maximum vacuum, electrical release pulse and −1 to 0 bar pressure transmitter with 0–10 V output.

SKU Festo-8049051 Category
Festo Vacuum Generators

Festo OVEL-10-H-15-PQ-VQ6-UA-C-A-V1V-H3 Vacuum Generator

BrandFesto
Model IdentifierOVEL-10-H-15-PQ-VQ6-UA-C-A-V1V-H3
Official Part Number8049051

Technical Overview

The Festo OVEL-10-H-15-PQ-VQ6-UA-C-A-V1V-H3 combines compressed-air vacuum generation, an electric on/off valve and an electrical ejector pulse in an 89 g T-shaped unit. Its 0.95 mm Laval nozzle provides up to 21 l/min suction flow against atmosphere at 4 bar supply, with 92% maximum vacuum specified at 3.8 bar. An integrated piezoresistive pressure transmitter measures −1 to 0 bar and provides a 0–10 V analogue output. The unit includes flow control, a filter and open silencer, with 6 mm supply and vacuum connections and a 2.5 m three-core sensor cable. Operation is specified at 2–7 bar, with IP40 protection.

High-vacuum ejector with 6 mm connections, electrical release pulse, 21 l/min maximum suction flow and 0–10 V pressure feedback.

Key Features

  • 0.95 mm Laval nozzle with high-vacuum characteristic
  • 21 l/min maximum suction flow against atmosphere at 4 bar supply
  • 92% maximum vacuum at 3.8 bar supply
  • Integrated electric on/off valve, electrical ejector pulse and flow control
  • Piezoresistive pressure transmitter with −1 to 0 bar measuring range
  • 0–10 V analogue output for pressure feedback
  • 6 mm supply and vacuum connections; integrated filter and open silencer
  • 24 V DC, 1.0 W coil data; 21.6–26.4 V valve range and 18–30 V sensor range
  • 2.5 m three-core sensor cable with open ends and energy-chain suitability
  • 89 g product weight, IP40 protection and 0–50 °C ambient range

Combine vacuum generation, an electrical release pulse and 0–10 V vacuum feedback in one 89 g unit with 6 mm pneumatic connections.

Technical Specification Matrix

ParameterValue
Nominal size, Laval nozzle0.95 mm
Mounting grid pitch15 mm
Silencer designOpen
Mounting positionAny
Ejector characteristicHigh vacuum; Standard
Grade of filtration40 µm
Manual overrideNon-detenting
Integrated functionEjector pulse, electrical; Flow control; Pressure transmitter; On/off valve, electric; Filter; Open silencer
DesignT-shape
Valve functionClosed
Measurement methodPiezoresistive pressure sensor
Operating pressure for max. suction flow rate0.4 MPa; 4 bar; 58 psi
Operating pressure0.2 MPa...0.7 MPa; 2 bar...7 bar; 29 psi...101.5 psi
Operating pressure for max. vacuum0.38 MPa; 3.8 bar; 55.1 psi
Max. vacuum92 %
Nominal operating pressure0.4 MPa; 4 bar; 58 psi
Max. suction flow rate against atmosphere21 l/min
Air supply time at nominal operating pressure with ejector pulse1 s
Analogue output0 - 10 V
Operational voltage range DC21.6 V...26.4 V
Duty cycle100%
Characteristic coil data24 V DC: 1.0 W
Approvalc UL us - Listed (Oil)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature0 °C...50 °C
Sound pressure level at nominal operating pressure68 dB(A)
Degree of protectionIP40
Ambient temperature0 °C...50 °C
Physical Weight (kg)0.089
Operating voltage range, DC sensor18 V...30 V
Pressure measuring range-0.1 MPa...0 MPa; -1 bar...0 bar; -14.5 psi...0 psi
Electrical connection input, functionEjector pulse; Vacuum generation
Electrical connection input, connection type2x plugs
Electrical connection input, connector systemPlug pattern H
Electrical connection input, number of connections/cores2
Input electrical connection, mounting typeSnap-locking
Electrical connection output, functionSensor
Electrical connection output, connection typeCable
Electrical connection output, connector systemOpen end
Electrical connection output, number of connections/cores3
Cable characteristicSuitable for energy chains
Cable diameter2.9 mm
Cable diameter tolerance± 0.1 mm
Cable length2.5 m
Nominal cross section conductor0.14 mm²
Type of mountingWith through-hole
Pneumatic connection, port 1For tubing outside diameter of 6 mm
Pneumatic connection, port 3Open silencer
Vacuum connectionFor tubing O.D. 6 mm
Cable sheath colourGrey
Material connecting threadPOM
Note on materialsRoHS compliant
Material sealsNBR
Material receiver nozzlePOM
Material filterPOM
Material housingReinforced PA
Material cable sheathPVC
Material adjusting screwSteel
Material screwsSteel
Material transmitter nozzleWrought aluminium alloy

Industrial Applications

1. Local Vacuum Supply for a Handling Head

A pick-and-place head needs a vacuum source close to its suction circuit. This unit converts compressed air through a 0.95 mm Laval nozzle and connects to the head through a QS-6 vacuum port. Its documented 21 l/min maximum atmospheric suction flow and 92% maximum vacuum describe the available ejector characteristics under their respective supply-pressure conditions.

Problem Solved

The integrated ejector provides a compact local vacuum source, allowing the handling circuit to use a defined pneumatic interface and documented flow and vacuum characteristics.

21 l/min atmospheric suction 92% maximum vacuum QS-6

2. Controlled Part Release at a Placement Station

A placement station must end vacuum generation and command a release pulse after depositing a component. The integrated electric on/off valve and electrical ejector-pulse function provide these two circuit actions at the generator. Built-in flow control provides an adjustment within the same assembly, while the separate electrical input functions identify vacuum generation and ejector pulse for the machine sequence.

Problem Solved

Electrical control of generation and ejector pulse supplies distinct handling and release actions from the same unit, supporting a defined transition from holding to placement.

Electrical ejector pulse Electric on/off valve Flow control

3. Vacuum-Level Feedback for Sequence Control

A handling machine needs measured vacuum information to coordinate the pneumatic sequence with the condition at its generator. The integrated piezoresistive transmitter covers −1 to 0 bar and supplies a 0–10 V analogue output through a three-core cable. The control system can read that signal alongside its vacuum-generation command, providing pressure information for process observation and sequence evaluation.

Problem Solved

The integrated pressure transmitter converts the vacuum condition into an analogue signal, giving the controller measured feedback from the same assembly that generates and releases the vacuum.

−1 to 0 bar 0–10 V output Integrated transmitter