Pepperl+Fuchs F2D0-FB-EX4.CGS Fieldbus Barrier

USD 2,254.08

4-output Ex ia IIC Fieldbus Barrier for Zone 1/Div. 2 with short-circuit current limitation, aluminum IP67 housing, supports FOUNDATION Fieldbus H1/PROFIBUS PA.

SKU PEPPERL-FUCHS-F2D0-FB-EX4.CGS Category
Top Brands > PEPPERL+FUCHS > PEPPERL+FUCHS Fieldbus Barriers

Pepperl+Fuchs F2D0-FB-EX4.CGS Fieldbus Barrier

Model Identifier F2D0-FB-EX4.CGS
Official Part Number F2D0-FB-EX4.CGS
GTIN Standard NA

Technical Overview

4-output Ex ia IIC Fieldbus Barrier for Zone 1/Div. 2 with short-circuit current limitation, aluminum IP67 housing, supports FOUNDATION Fieldbus H1/PROFIBUS PA.

Key Features

  • 4 outputs Ex ia IIC
  • FieldBarrier in Zone 1/Div. 2
  • Instruments connectable in Zone 0/Div. 1
  • Short circuit current limitation per output
  • Supports FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Integrated Power, Com, and Error LEDs for troubleshooting
  • Supports FISCO and Entity communication protocols
  • Integrated cable tie-downs
  • Sturdy cast aluminum housing (IP67) for rough environments
  • High power on trunk enables maximum cable lengths and device count
  • Selectable integrated fieldbus terminator
  • Choice of fixed screw or spring output terminals
  • Configurable hard and capacitive grounding and shielding

4 intrinsically safe outputs Ex ia IIC with short circuit current limitation per output

Technical Specification Matrix

ParameterValue
Design / MountingOutside installation
Installation in hazardous areaZone 1/Div. 2
Instruments connectable in hazardous areaZone 0/Div. 1
Electronic componentFieldBarrier RD0-FB-Ex4.*
Main cable (Trunk) Cable entry typeCable gland, stainless steel, M20
Number of outputs4
Cable entry type (Output)Cable gland, stainless steel, M16
Degree of protectionIP67 (EN 60529)
Shock resistance standardEN 60068-2-27
Vibration resistance standardEN 60068-2-6
Ambient temperature range-40 ... 85 °C (-40 ... 185 °F)
Storage temperature range-40 ... 85 °C (-40 ... 185 °F)
Connection typeScrew terminal, fixed
Enclosure coverDetachable with retaining screws
Housing materialAluminum
Material SurfacePainted green
Material SealSilicone, one-piece
MountingWall mounting
GroundingM5 threading for grounding bolt
EU-type examination certificatePTB 02 ATEX 2086
MarkingII 2 (1) G Ex eb mb [ia Ga] IIC T4 Gb
Marking (Dust)II 2 (1) D Ex tb [ia Da] IIIC 130 °C Db
Directive conformityEN IEC 60079-0:2018+AC:2020, EN 60079-7:2015+A1:2018, EN 60079-11:2012, EN 60079-18:2015+A1:2017, EN 60079-31:2014
FM approvalCoC 3015728
FM Approved forClass I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx nA [ia] IIC T4
CSA approvalCoC 1845315
CSA Approved forClass I, Division 2, Groups A, B, C, D / Class I, Zone 2, Ex nA [ia] IIC T4
IECEx certificateIECEX PTB 03.0003
IECEx markingEx eb mb [ia Ga] IIC T4 Gb, Ex tb [ia Da] IIIC 130 °C Db
FOUNDATION Fieldbus CertificateFF-846
Physical Weight (kg)3.35
Dimensions L x W x H (cm)25.8 x 14 x 8.4

Industrial Applications

1. Intrinsically Safe Fieldbus Integration in Chemical Reactors

Integrating field instruments (e.g., temperature, pressure, level sensors) in highly volatile chemical reactor environments (Zone 0/Div. 1) that require intrinsic safety to prevent ignition. The FieldBarrier connects these instruments to the control system via FOUNDATION Fieldbus H1 or PROFIBUS PA, ensuring data integrity and safety.

Problem Solved

Prevents potential ignition in explosive atmospheres (e.g., hydrogen, acetylene, carbon disulfide) by providing intrinsically safe power and data connections to field devices in Zone 0/Div. 1 hazardous areas, while allowing easy troubleshooting with integrated LEDs.

Intrinsic SafetyZone 0/Div. 1Chemical ReactorFOUNDATION FieldbusPROFIBUS PAHazardous Area ClassificationExplosion ProtectionProcess Instrumentation

2. Field Device Connectivity for Offshore Platforms and Refineries

Providing robust and intrinsically safe connectivity for various sensors and actuators on offshore oil and gas platforms or in refinery process units where explosive gas mixtures are present (Zone 1/Div. 2). The aluminum housing and IP67 rating ensure durability in harsh marine or industrial environments.

Problem Solved

Enables reliable and safe communication for multiple field instruments in outdoor, potentially explosive environments (Zone 1/Div. 2) such as wellheads, storage tanks, and pipelines, protecting against faults and ensuring continuous operation in corrosive and humid conditions.

Oil & GasOffshore PlatformRefineryIntrinsic SafetyZone 1/Div. 2IP67Robust HousingFieldbus CommunicationSensor Integration

3. Hazardous Area Instrumentation for Solvent-Based Production

Interfacing process instrumentation in pharmaceutical facilities that handle flammable solvents during active pharmaceutical ingredient (API) production. The FieldBarrier's short circuit current limitation per output and Ex ia IIC certification are crucial for maintaining safety standards in potentially explosive atmospheres.

Problem Solved

Safely connects multiple intrinsically safe instruments in pharmaceutical manufacturing areas where flammable solvents create hazardous zones, preventing fault propagation and ensuring process control integrity without compromising explosion protection.

Pharmaceutical ProductionFlammable SolventsAPI ManufacturingIntrinsic SafetyEx ia IICHazardous Area InstrumentationProcess ControlExplosion Protection
Select your currency