Pepperl+Fuchs KFD0-RO-2 2-Channel Relay Module

USD 167.28

2-channel signal conditioner with SIL 3 functional safety, 15-30V DC input, 230V AC/4A or 30V DC/4A relay output, IP20, and galvanic isolation.

SKU PEPPERL-FUCHS-KFD0-RO-2 Category
Top Brands > PEPPERL+FUCHS > PEPPERL+FUCHS Relay Modules

Pepperl+Fuchs KFD0-RO-2 2-Channel Relay Module

Model Identifier KFD0-RO-2
Official Part Number KFD0-RO-2
GTIN Standard NA

Technical Overview

2-channel signal conditioner with SIL 3 functional safety, 15-30V DC input, 230V AC/4A or 30V DC/4A relay output, IP20, and galvanic isolation.

Key Features

  • 2-channel signal conditioner
  • 24 V DC supply (loop powered)
  • Logic input 15 V DC to 30 V DC, non-polarized
  • Relay contact output
  • Up to SIL 3 functional safety according to IEC/EN 61508
  • Reinforced galvanic isolation between input and output
  • LED indicators for relay output status
  • DIN rail mounting (35 mm EN 60715)
  • Fast response times: 10 ms energize / 5 ms de-energize

Achieves Safety Integrity Level (SIL) 3 compliance, ensuring critical safety functions in industrial processes requiring high integrity.

Technical Specification Matrix

ParameterValue
Signal TypeDigital Output
Safety Integrity Level (SIL)SIL 3 (acc. to IEC/EN 61508)
Rated Voltage (Supply)15 ... 30 V DC, loop powered
Power Dissipation0.8 W
Input Voltage15 ... 30 V DC
Input Current≤ 21 mA per channel
Output Contact Loading230 V AC / 4 A / cos φ > 0.7; 30 V DC / 4 A resistive load
Energized/De-energized delayapprox. 10 ms / approx. 5 ms
Mechanical Life5 x 10^6 switching cycles
Electrical Life10^5 switching cycles (at maximum load)
Switching Frequency< 10 Hz
Galvanic IsolationInput/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Ambient Temperature-20 ... 65 °C (-4 ... 149 °F)
Degree of ProtectionIP20
Mounting35 mm DIN mounting rail acc. to EN 60715:2001
Physical Weight (kg)0.1
Dimensions L x W x H (cm)11.5 x 2 x 11.9

Industrial Applications

1. Emergency Shutdown System (ESD) in Chemical Plants

The KFD0-RO-2 can be integrated into critical Emergency Shutdown Systems in chemical processing plants to reliably de-energize actuators or trigger alarms. Its SIL 3 rating and galvanic isolation ensure high safety integrity for process interruptions.

Problem Solved

Provides a highly reliable, safety-rated interface for critical shutdown sequences, preventing catastrophic failures and ensuring operational safety in hazardous chemical environments by isolating control signals and ensuring rapid response.

SIL 3Galvanic IsolationRelay OutputEmergency ShutdownProcess Safety15-30V DC Input

2. Safe Actuation of Valves in Oil & Gas Pipelines

This module is suitable for controlling safety-instrumented valves (e.g., emergency block valves) in oil and gas pipelines. It offers isolated switching based on control system commands, protecting the control system from field-side electrical disturbances.

Problem Solved

Ensures safe and isolated control of critical field devices like valves in volatile oil and gas operations. Its SIL 3 compliance and robust relay outputs prevent uncontrolled flows or pressures, enhancing system reliability.

SIL 3Relay Contact OutputGalvanic IsolationPipeline ControlHazardous Area (implied)Process Control

3. Interfacing Fire Alarm Systems with Building Management

The KFD0-RO-2 can serve as a dependable interface between a fire alarm control panel and other Building Management Systems (BMS) to activate critical safety measures such as smoke dampers or ventilation system shutdowns. Its galvanic isolation prevents electrical interference between disparate systems.

Problem Solved

Offers a highly reliable and galvanically isolated digital output for building safety components, ensuring quick (10ms energize delay) and dependable responses during fire emergencies, while mitigating risks of electrical noise impacting system integrity.

Digital OutputSIL 3Galvanic IsolationFast ResponseBuilding AutomationFire Safety