Phoenix Contact MACX MCR-T-UI-UP Temperature Transmitter

$ 319.93

Discover the Phoenix Contact MACX MCR-T-UI-UP transmitter with SIL 2 safety, wide sensor support, and reliable signal conversion for industrial control.

Product Description

Phoenix Contact MACX MCR-T-UI-UP Temperature Transmitter – Precision Monitoring with Flexible Configuration

The Phoenix Contact MACX MCR-T-UI-UP temperature transmitter is a versatile and programmable device engineered to provide accurate and stable temperature measurement in industrial environments. Designed for use with RTDs, thermocouples, potentiometers, and low-voltage signals, it offers reliable signal conversion even under challenging conditions. Built with 4-way isolation and certified to SIL 2 safety standards, the unit enhances process reliability while ensuring compliance with strict safety requirements. Its wide supply voltage range, compact DIN-rail design, and capability for programming during operation allow seamless integration, solving the common challenge of maintaining dependable temperature control in complex applications.

The MACX MCR-T-UI-UP transmitter delivers significant advantages to engineers and plant operators by combining safety, flexibility, and durability. Features such as cold-junction compensation, programmable input/output signals, and integrated relay switching ensure precision and adaptability across diverse processes. With intuitive setup via software or operator interface, adjustments can be made quickly without interrupting production. Its slim housing saves valuable panel space, while robust resistance to vibration, shock, and varying temperatures guarantees reliable operation in harsh conditions. Ideal for energy systems, process automation, and machine building, this transmitter helps reduce downtime, improves efficiency, and ensures long-term operational stability.

Why Phoenix Contact MACX MCR-T-UI-UP?

Because it combines precision, safety, and flexibility in one compact solution. The MACX MCR-T-UI-UP adapts to multiple sensor types, delivers highly accurate measurements, and ensures reliable signal conversion under tough industrial conditions. With programmable input/output, relay functions, and international safety approvals, it is a trusted choice for engineers seeking both performance and long-term reliability.

What Problem Does It Solve?

In many plants, unstable signals, sensor mismatches, and difficult field conditions lead to measurement errors and downtime. The MACX MCR-T-UI-UP solves this by offering 4-way isolation, cold-junction compensation, and flexible configuration for diverse sensors. It ensures that temperature data is transmitted accurately, safely, and without interruption—helping operators maintain control, reduce maintenance costs, and prevent costly system failures.

 


Key Features & Specifications – Phoenix Contact MACX MCR-T-UI-UP: 2811394

Feature Details Benefit
Supply Voltage Range 19.2…253 V AC/DC Flexible power compatibility in various systems
Input Types RTDs, thermocouples, resistors, potentiometers, mV sources Wide application coverage with multiple sensor options
Temperature Range -250 °C to +2500 °C (depending on sensor) Supports extreme industrial environments
Output Signal 0/4…20 mA, ±11 V, programmable Adaptable to different control and monitoring systems
Relay Output 1 changeover contact, AgSnO2 gold-plated Reliable switching for alarms and safety triggers
Isolation 4-way isolation, 2.5 kV test voltage Protects equipment and ensures measurement integrity
Safety Compliance SIL 2 (IEC 61508), PL d (ISO 13849-1) Certified safety for critical process industries
Mounting DIN rail, 17.5 mm width Saves panel space with quick installation
Protection Class IP20 Suitable for protected industrial control cabinets
Ambient Temperature -20 °C to +65 °C Reliable operation under demanding conditions
Approvals CE, ATEX, IECEx, UL, DNV, INMETRO Global certification for versatile use

Download Phoenix Contact MACX MCR-T-UI-UP 2811394 Datasheet

 


Commercial Information – Phoenix Contact MACX MCR-T-UI-UP: 2811394

Commercial Data Details
GTIN Number 4046356520294
Tariff Number 85437090
Weight (Net) 193.9 g
Country of Origin Germany (DE)

 


The Applications of Phoenix Contact MACX MCR-T-UI-UP

1.Temperature Profiling in Petrochemical Distillation
In petrochemical plants, precise monitoring of temperature at different column levels is essential to separate products with close boiling points. The MACX MCR-T-UI-UP, with its wide sensor compatibility and SIL 2 safety rating, ensures accurate and stable signal conversion even in demanding environments. Its programmable outputs and relay switching enable reliable alarms and control adjustments, minimizing process inefficiencies. By reducing errors caused by wiring resistance or sensor drift, this transmitter helps operators maintain high product yield and energy efficiency across critical distillation processes.

2.Reactor Safety in Chemical Processing
Chemical reactors operate under high stress, with volatile reactions and hazardous conditions that demand dependable safety systems. The MACX MCR-T-UI-UP supports both RTD and thermocouple inputs while offering strong electrical isolation to protect critical instrumentation. Its integrated relay output provides immediate alarm capability when abnormal temperature levels occur. With certification for SIL 2 applications, the device strengthens safety instrumented systems, ensuring that operators can detect sensor failures early and prevent uncontrolled conditions, safeguarding both people and assets.

3.Food and Beverage Pasteurization Control
In beverage and dairy production, pasteurization requires consistent temperature control to guarantee product safety without compromising taste or quality. The MACX MCR-T-UI-UP delivers fast response times and accurate conversion of sensor signals, ensuring stable regulation of steam or hot water systems. Its programmable features allow quick setup for different recipes, while relay outputs can trigger alarms if temperature deviates from the set range. This capability reduces waste, improves consistency across production batches, and maintains regulatory compliance in food safety standards.

4.Pump and Motor Temperature Monitoring in Water Treatment
Wastewater treatment facilities rely on pumps and motors that often operate in corrosive or hazardous environments. Overheating of bearings, windings, or pipeline systems can lead to costly downtime. The MACX MCR-T-UI-UP, certified for installation in Zone 2 areas, provides secure monitoring through robust isolation and reliable signal transmission. Its compatibility with multiple sensor types allows flexible deployment across equipment, while its alarm relay ensures maintenance teams are alerted before critical failures occur. This helps extend equipment lifespan and improves operational reliability.

 


Related Products & Accessories – Phoenix Contact MACX MCR-T-UI-UP

Category Accessory / Related Product Part Number Purpose / Benefit
Connector Protection Cover for Screw Shafts (EA-MSTB 2,5/5) 1831016 Protects screw connector shafts, ensuring safe and clean connections.
Mounting Accessory Separating Plate (MCR-DP) 1430594 Maintains isolating distances when mounting Ex i and non-Ex i devices side by side on DIN rail.
Programming Tool Programming Adapter USB (IFS-USB-PROG-ADAPTER) 2811271 Enables configuration via software with USB interface, supporting voltage-free programming.
Programming Tool Bluetooth Programming Adapter (IFS-BT-PROG-ADAPTER) 2905872 Allows wireless configuration and monitoring of MACX Analog devices.
Signal Connection Current Plug (MACX MCR-I20) 2905680 Terminal block for ±20 mA current signals, used for safe switching of limit values.
Signal Compensation Cold Junction Compensation Plug (MACX MCR-CJC) 2924993 Provides cold junction compensation for thermocouple applications.
Wiring Accessory Insulating Sleeves (MPS-IH Series, multiple colors) 0201663 / 0201676 / 0201689 / 0201692 / 0201702 / 0201728 / 0201731 Color-coded sleeves for safe wiring identification and easy troubleshooting.
Testing Tool Test Plug (MPS-MT) 0201744 Enables quick testing of terminals with solder connections up to 1 mm² conductor size.
Labeling & Identification Device Marking Labels (UC-EMLP, US-EMLP, LS-EMLP Series) Multiple part numbers Adhesive labels in various colors and finishes for equipment identification.
Power Supply QUINT4 Power Supply (QUINT4-SYS-PS/1AC/24DC/2.5/SC) 2904614 Provides reliable 24 V DC output, suitable for powering MACX transmitters.
Tool Screwdriver (SZS 0,6X3,5) 1205053 Insulated screwdriver designed for use with terminal blocks and device installation.

 


Contact Us

For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.

Select your currency