Discover Phoenix Contact MACX MCR-T-UIREL-UP-SP, a programmable temperature transmitter with SIL 2 safety, 4-way isolation, and flexible sensor inputs.
The Phoenix Contact MACX MCR-T-UIREL-UP-SP temperature transmitter is engineered for precise measurement and safe signal conversion across a wide range of industrial applications. It accepts inputs from thermocouples, resistance thermometers, potentiometers, and low-level voltage signals, giving engineers flexibility when integrating into process systems. Designed with four-way electrical isolation and SIL 2 safety compliance, it provides dependable protection and reliability. Its wide power supply range and compact DIN rail housing make it easy to deploy in diverse environments, from energy plants to automated production lines, ensuring accuracy and safety even under demanding conditions.
The MACX MCR-T-UIREL-UP-SP offers more than standard signal conditioning. With user-friendly programming options and real-time configuration, it allows quick adaptation to system requirements without interrupting operations. Features such as cold junction compensation stabilize thermocouple readings, while inverse output ranges add design flexibility. Its robust certifications make it suitable for hazardous areas, supporting compliance with global safety standards. In practice, this translates into simplified installation, reduced wiring effort, and minimized downtime. Whether applied in process automation, machine safety, or energy monitoring, this transmitter ensures consistent performance and enhances overall system efficiency.
The MACX MCR-T-UIREL-UP-SP stands out because it combines flexibility, safety, and precision in one device. It accepts multiple sensor types, provides four-way electrical isolation, and is certified for use in hazardous areas. Engineers choose it because it reduces installation effort, adapts easily to changing process demands, and delivers trustworthy performance under tough conditions. Its intelligent features allow real-time configuration, ensuring systems stay efficient and secure without costly downtime.
Industrial plants often struggle with inaccurate readings, wiring complexity, and safety risks in temperature monitoring. The MACX MCR-T-UIREL-UP-SP solves these issues by offering stable signal conversion, cold junction compensation, and configurable relays for reliable process control. By unifying measurement, isolation, and safety in a single compact module, it minimizes wiring errors, improves operational safety, and ensures compliance with strict industry standards. This leads to more accurate data, smoother operations, and reduced maintenance costs.
Feature | Details | Benefit |
---|---|---|
Input Compatibility | RTDs, thermocouples, potentiometers, mV sources | Flexible use across multiple sensor types |
Measuring Range | -250 °C to +2500 °C (sensor dependent) | Covers extreme industrial temperature conditions |
Output Signal | 0–20 mA, 4–20 mA, ±11 V programmable | Wide integration with PLC/DCS systems |
Relays | 3 changeover relays (AgSnO₂ gold-plated) | Reliable limit monitoring and safety signaling |
Electrical Isolation | 4-way isolation | Protects system integrity and prevents cross-interference |
Safety Compliance | SIL 2 (IEC 61508), PL d (ISO 13849) | Meets rigorous safety requirements |
Power Supply | 24–230 V AC/DC | Universal supply flexibility |
Configuration Options | Software (FDT/DTM), operator panel, USB/Bluetooth adapters | Easy setup and adjustment without downtime |
Mounting Type | DIN rail, 35 mm | Space-saving, quick installation |
Protection Rating | IP20 | Suitable for controlled industrial environments |
Approvals | ATEX, IECEx, UL, DNV | Certified for global use including hazardous zones |
Download MACX MCR-T-UIREL-UP-SP 2811828 Datasheet
Commercial Data | Details |
---|---|
GTIN Number | 4046356579483 |
Tariff Number | 85437090 |
Weight | 120 g (net) / 343.4 g (gross) |
Country of Origin | Germany |
Petrochemical facilities depend on precise monitoring of outlet temperatures in heat exchangers to balance energy efficiency and safety. By connecting RTDs or thermocouples to the MACX MCR-T-UIREL-UP-SP, operators gain reliable conversion of readings into stable current outputs. The transmitter’s four-way isolation protects against interference across large installations, while programmable relays can activate alarms or shut down equipment when values exceed safe ranges. This ensures process stability, prevents overheating, and avoids costly product losses in demanding chemical environments.
In machinery such as turbines, compressors, and motors, unexpected rises in bearing temperature can lead to rapid failure. Using the MACX MCR-T-UIREL-UP-SP with embedded RTDs provides real-time signal conditioning and dependable output for monitoring systems. With its SIL 2 rating and integrated limit relays, it enables early intervention or automatic shutdown if overheating occurs. Cold junction compensation adds stability, while the DIN-rail format simplifies cabinet integration. The result is improved asset protection, fewer unplanned stoppages, and extended equipment service life.
Industrial boilers require constant assurance that pilot flames remain active for safe operation. A thermocouple can detect flame status, but raw signals are easily disrupted. The MACX MCR-T-UIREL-UP-SP ensures these signals are converted into robust analog outputs, free from noise, and backed by configurable relays that trigger safety interlocks if the flame extinguishes. Its inverse output options add flexibility in designing thresholds. This improves reliability in flame monitoring, reducing false trips while maintaining stringent safety levels in heating systems.
Temperature-sensitive pharmaceuticals must remain within strict storage ranges to preserve quality and compliance. By pairing RTD sensors with the MACX MCR-T-UIREL-UP-SP, precise data can be delivered to centralized monitoring systems with dependable current signals. Configurable relays can trigger alarms or activate backup cooling if deviations are detected. The unit’s compact design and SIL 2 compliance support installation in controlled environments that demand high safety standards. This ensures continuous oversight of critical storage conditions, minimizing waste and safeguarding product integrity.
Category | Model Name | Part Number | Benefits |
---|---|---|---|
Separating Plate | MCR-DP | 1430594 | Maintains safe isolating distances when mounting Ex i and non-Ex i devices side by side on a DIN rail. |
Programming Adapter (USB) | IFS-USB-PROG-ADAPTER | 2811271 | Enables programming and configuration via USB with included software driver. |
Programming Adapter (Bluetooth) | IFS-BT-PROG-ADAPTER | 2905872 | Wireless configuration through Bluetooth for faster commissioning and adjustments. |
Connection Plug | MACX MCR-I20 | 2905680 | Provides safe switching of current signals (+20 mA…-20 mA) in combination with MACX temperature transducers. |
Cold Junction Compensation Plug | MACX MCR-CJC | 2924993 | Ensures stable thermocouple measurement accuracy through reliable cold junction compensation. |
Insulating Sleeves | MPS-IH Series (WH, RD, BU, YE, GN, GY, BK) | 0201663–0201731 | Color-coded insulating sleeves for safe wiring identification and electrical insulation. |
Test Plug | MPS-MT | 0201744 | Test plug with solder connection for quick diagnostics and maintenance. |
Device Marking Labels | UC-EMLP / US-EMLP / LS-EMLP Series | 0819291–0831732 | Adhesive plastic labels for clear device marking, available in multiple colors and sizes. |
Power Supply | QUINT4-SYS-PS/1AC/24DC/2.5/SC | 2904614 | High-reliability DIN rail power supply providing stable 24 V DC output for the transmitter. |
Actuation Tool | SZS 0,6X3,5 Screwdriver | 1205053 | Insulated screwdriver compatible with Phoenix Contact terminal blocks for safe wiring. |
For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.