Phoenix Contact MACX MCR-T-UIREL-UP-SP Temperature Transmitter

The Phoenix Contact MACX MCR-T-UIREL-UP-SP temperature transmitter is engineered for precise measurement and safe signal conversion across a wide range of industrial applications. It accepts inputs from thermocouples, resistance thermometers, potentiometers, and low-level voltage signals, giving engineers flexibility when integrating into process systems. Designed with four-way electrical isolation and SIL 2 safety compliance, it provides dependable protection and reliability. Its wide power supply range and compact DIN rail housing make it easy to deploy in diverse environments, from energy plants to automated production lines, ensuring accuracy and safety even under demanding conditions.

The MACX MCR-T-UIREL-UP-SP offers more than standard signal conditioning. With user-friendly programming options and real-time configuration, it allows quick adaptation to system requirements without interrupting operations. Features such as cold junction compensation stabilize thermocouple readings, while inverse output ranges add design flexibility. Its robust certifications make it suitable for hazardous areas, supporting compliance with global safety standards. In practice, this translates into simplified installation, reduced wiring effort, and minimized downtime. Whether applied in process automation, machine safety, or energy monitoring, this transmitter ensures consistent performance and enhances overall system efficiency.

Why Phoenix Contact MACX MCR-T-UIREL-UP-SP?

The MACX MCR-T-UIREL-UP-SP stands out because it combines flexibility, safety, and precision in one device. It accepts multiple sensor types, provides four-way electrical isolation, and is certified for use in hazardous areas. Engineers choose it because it reduces installation effort, adapts easily to changing process demands, and delivers trustworthy performance under tough conditions. Its intelligent features allow real-time configuration, ensuring systems stay efficient and secure without costly downtime.

What Problem Does It Solve?

Industrial plants often struggle with inaccurate readings, wiring complexity, and safety risks in temperature monitoring. The MACX MCR-T-UIREL-UP-SP solves these issues by offering stable signal conversion, cold junction compensation, and configurable relays for reliable process control. By unifying measurement, isolation, and safety in a single compact module, it minimizes wiring errors, improves operational safety, and ensures compliance with strict industry standards. This leads to more accurate data, smoother operations, and reduced maintenance costs.

 


Key Features & Specifications – Phoenix Contact MACX MCR-T-UIREL-UP-SP: 2811828

Feature Details Benefit
Input Compatibility RTDs, thermocouples, potentiometers, mV sources Flexible use across multiple sensor types
Measuring Range -250 °C to +2500 °C (sensor dependent) Covers extreme industrial temperature conditions
Output Signal 0–20 mA, 4–20 mA, ±11 V programmable Wide integration with PLC/DCS systems
Relays 3 changeover relays (AgSnO₂ gold-plated) Reliable limit monitoring and safety signaling
Electrical Isolation 4-way isolation Protects system integrity and prevents cross-interference
Safety Compliance SIL 2 (IEC 61508), PL d (ISO 13849) Meets rigorous safety requirements
Power Supply 24–230 V AC/DC Universal supply flexibility
Configuration Options Software (FDT/DTM), operator panel, USB/Bluetooth adapters Easy setup and adjustment without downtime
Mounting Type DIN rail, 35 mm Space-saving, quick installation
Protection Rating IP20 Suitable for controlled industrial environments
Approvals ATEX, IECEx, UL, DNV Certified for global use including hazardous zones

Download MACX MCR-T-UIREL-UP-SP 2811828 Datasheet


Commercial Information – Phoenix Contact MACX MCR-T-UIREL-UP-SP

Commercial Data Details
GTIN Number 4046356579483
Tariff Number 85437090
Weight 120 g (net) / 343.4 g (gross)
Country of Origin Germany

 


The Applications of Phoenix Contact MACX MCR-T-UIREL-UP-SP

1. Heat Exchanger Performance in Petrochemical Plants

Petrochemical facilities depend on precise monitoring of outlet temperatures in heat exchangers to balance energy efficiency and safety. By connecting RTDs or thermocouples to the MACX MCR-T-UIREL-UP-SP, operators gain reliable conversion of readings into stable current outputs. The transmitter’s four-way isolation protects against interference across large installations, while programmable relays can activate alarms or shut down equipment when values exceed safe ranges. This ensures process stability, prevents overheating, and avoids costly product losses in demanding chemical environments.

2. Bearing Temperature Monitoring in Rotating Equipment

In machinery such as turbines, compressors, and motors, unexpected rises in bearing temperature can lead to rapid failure. Using the MACX MCR-T-UIREL-UP-SP with embedded RTDs provides real-time signal conditioning and dependable output for monitoring systems. With its SIL 2 rating and integrated limit relays, it enables early intervention or automatic shutdown if overheating occurs. Cold junction compensation adds stability, while the DIN-rail format simplifies cabinet integration. The result is improved asset protection, fewer unplanned stoppages, and extended equipment service life.

3. Safety Assurance in Industrial Boiler Systems

Industrial boilers require constant assurance that pilot flames remain active for safe operation. A thermocouple can detect flame status, but raw signals are easily disrupted. The MACX MCR-T-UIREL-UP-SP ensures these signals are converted into robust analog outputs, free from noise, and backed by configurable relays that trigger safety interlocks if the flame extinguishes. Its inverse output options add flexibility in designing thresholds. This improves reliability in flame monitoring, reducing false trips while maintaining stringent safety levels in heating systems.

4. Cold Chain Control for Pharmaceutical Storage

Temperature-sensitive pharmaceuticals must remain within strict storage ranges to preserve quality and compliance. By pairing RTD sensors with the MACX MCR-T-UIREL-UP-SP, precise data can be delivered to centralized monitoring systems with dependable current signals. Configurable relays can trigger alarms or activate backup cooling if deviations are detected. The unit’s compact design and SIL 2 compliance support installation in controlled environments that demand high safety standards. This ensures continuous oversight of critical storage conditions, minimizing waste and safeguarding product integrity.

 


Related Products & Accessories – Phoenix Contact MACX MCR-T-UIREL-UP-SP

Category Model Name Part Number Benefits
Separating Plate MCR-DP 1430594 Maintains safe isolating distances when mounting Ex i and non-Ex i devices side by side on a DIN rail.
Programming Adapter (USB) IFS-USB-PROG-ADAPTER 2811271 Enables programming and configuration via USB with included software driver.
Programming Adapter (Bluetooth) IFS-BT-PROG-ADAPTER 2905872 Wireless configuration through Bluetooth for faster commissioning and adjustments.
Connection Plug MACX MCR-I20 2905680 Provides safe switching of current signals (+20 mA…-20 mA) in combination with MACX temperature transducers.
Cold Junction Compensation Plug MACX MCR-CJC 2924993 Ensures stable thermocouple measurement accuracy through reliable cold junction compensation.
Insulating Sleeves MPS-IH Series (WH, RD, BU, YE, GN, GY, BK) 0201663–0201731 Color-coded insulating sleeves for safe wiring identification and electrical insulation.
Test Plug MPS-MT 0201744 Test plug with solder connection for quick diagnostics and maintenance.
Device Marking Labels UC-EMLP / US-EMLP / LS-EMLP Series 0819291–0831732 Adhesive plastic labels for clear device marking, available in multiple colors and sizes.
Power Supply QUINT4-SYS-PS/1AC/24DC/2.5/SC 2904614 High-reliability DIN rail power supply providing stable 24 V DC output for the transmitter.
Actuation Tool SZS 0,6X3,5 Screwdriver 1205053 Insulated screwdriver compatible with Phoenix Contact terminal blocks for safe wiring.

 


Contact Us

For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.

Select your currency