Skip to content

Contact Us:
sales@inosaki.com

SICK 6052873 PRO2-P100B25A1 PNP Laser Profile Sensor

SICK 6052873 PRO2-P100B25A1 PNP Laser Profile Sensor

USD 6,187.48

75–125 mm profile sensor with 17–27 mm distance-dependent measuring width, built-in geometric functions, three PNP outputs, 4–20 mA signal and RS-485.

SKU: SICK-6052873 Category:
Laser Distance Sensors - SICK Profiler

SICK PRO2-P100B25A1 PNP Laser Profile Sensor

BrandSICK
Model IdentifierPRO2-P100B25A1
Official Part Number6052873

Technical Overview

The SICK PRO2-P100B25A1 measures a laser line profile over a 75–125 mm distance range. Receiving width is 17 mm at 75 mm, 22 mm at 100 mm and 27 mm at 125 mm, distinct from the projected 32 mm laser line. Built-in functions evaluate height, width, edge position, tilt, area and other profile features. Three PNP outputs, a 4–20 mA output and RS-485 support process integration. Averaging from 1–1,023 and adjustable sensitivity adapt evaluation; the stated response is ≥5 ms, typical in high-resolution mode. A dot-matrix display and local buttons support setup. The class 2 red-laser sensor has an IP67 zinc-diecast housing and requires up to 30 minutes of warm-up.

75–125 mm laser line-profile sensor with distance-dependent 17–27 mm receiving width, geometric measurement functions, three PNP outputs, 4–20 mA and RS-485.

Key Features

  • 75–125 mm measuring distance
  • Receiving width17/22/27 mm at75/100/125 mm respectively
  • 655 nm class2 laser;typical projected line0.3 ×32 mm
  • Profile functions include height,width,edge position/count,tilt,area,length and diameter
  • Averaging1–1,023;adjustable sensitivity
  • Three PNP outputs;maximum output current≤100 mA
  • 4–20 mA analog output;load≤300 Ω;24 mA out-of-range signal
  • RS-485,9.6 kbit/s–4 Mbit/s,half-duplex
  • Dot-matrix display;cursor,EXIT andSET buttons;warm-up≤30 min
  • IP67 zinc-diecast housing;HRS12-pin I/O and6-pin communication connectors

Evaluate height, width and edge features across a laser profile, then pass measurement values or switching conditions to external machine control.

Technical Specification Matrix

ParameterValue
Functional principleLaser line-profile geometric measurement
Measuring range75–125 mm
Receiving measuring width17 mm at75 mm;22 mm at100 mm;27 mm at125 mm
Projected laser lineTypical0.3 ×32 mm;distinct from usable receiving field
X repeatabilityTypical25 µm;depends on settings and field of view;90%remission white ceramic,256 averages,constant ambient conditions
Z repeatability2 µm;90%remission white ceramic,256 averages,constant ambient conditions
X linearity±170 to±270 µm;90%remission white ceramic;constant ambient conditions
Z linearity±50 µm;90%remission white ceramic;constant ambient conditions
Receiving-field X resolution25 µm at75 mm;33 µm at100 mm;40 µm at125 mm
Response time≥5 ms;typical value in high-resolution mode
Light sourceVisible red laser
Wavelength655 nm
Laser class2;IEC60825-1:2014 and EN60825-1:2014
Maximum optical output1 mW
Laser handlingDo not intentionally look into the beam or point it at eyes
Measurement functionsAverage,peak height,bottom height,width,peak-height position,bottom-height position,edge position,edge count,tilt,area,length,diameter
Averaging1–1,023
SensitivityAdjustable
TimerON/OFF delay,one shot or off
Digital outputs3 ×PNP;maximum output current≤100 mA
Analog output1 ×4–20 mA;load≤300 Ω;24 mA indicates measuring out of range
Serial interfaceRS-485;9.6 kbit/s–4 Mbit/s;half-duplex
External input functionsBank,trigger,hold,reset,laser off or offset
Power supply12 V DC−5% to24 V DC+10% for selected current-output configuration
Current consumption≤180 mA
Warm-up time≤30 min
DisplayDot-matrix display;operating and laser LEDs
ControlsCursor,EXIT andSET buttons
Protection classIII
I/O and power connectionHRS12-pin female connector
Communication connectionHRS6-pin male connector
I/O pin functions1=L+;2=0 V;3=offset/laser off;4=BANK1/reset;5=BANK2/hold;6=BANK3/trigger;7=Q2;8=Q1;9=Q3;10=analog ground;11=QA;12=shield
Housing materialZinc diecast
Window materialPolycarbonate plastic
IP ratingIP67
Operating temperature−10 to+40 °C at24 V supply
Storage temperature−20 to+60 °C
Relative humidity≤85%;non-condensing
Temperature drift±0.05%FS/K;FS=full sensor measuring range
Ambient light immunityTypical artificial light≤3,000 lx;sunlight≤10,000 lx
Vibration resistance10–55 Hz,1.5 mm amplitude;X/Y/Z axes2 hours each
Shock resistance50 g;X/Y/Z axes3 times each
Physical Weight (kg)0.3

Industrial Applications

1. Inspecting a raised feature on an assembly

An assembly fixture can place a raised feature and adjacent surface within the receiving field at the selected 75–125 mm standoff. Peak-height or bottom-height evaluation extracts the chosen profile feature, and external control compares its measured condition with the application reference. Averaging, actual surface return and the30-minute warm-up limit are included in setup before setting inspection thresholds.

Problem Solved

A line profile supplies height information across a local feature, allowing external inspection logic to evaluate raised or recessed geometry instead of relying on a single-point presence event.

Profile height Local geometry External inspection

2. Checking the width of a groove or bead

A production station can present a groove or bead across the laser profile with both boundaries inside the receiving field. The width function evaluates the selected feature, and the result is sent through the configured measurement or switching interface. The selected standoff determines the available field width and X resolution, so the inspection is calibrated on the actual part geometry.

Problem Solved

Evaluating the separation of feature boundaries supplies a width condition for external quality control, distinguishing an undersized or oversized feature from a simple present/absent result.

Width function Receiving field X resolution

3. Tracking an edge for external guiding control

A feeder can position a sufficiently reflective material edge within the profile field and use edge-position evaluation to follow its lateral movement. The measured result reaches an external guiding controller through the selected analog or serial interface. That controller implements correction, while sensor averaging, response and field width are matched to the required process behavior.

Problem Solved

A numerical edge position lets external control follow lateral drift across the receiving field, providing directional information beyond a single threshold crossing at a fixed detection point.

Edge position External guiding Analog or serial data