Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Item number | 2981020 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DNA161 |
Catalog page | Page 256 (C-6-2019) |
GTIN | 4017918911065 |
Weight per piece (including packing) | 183.05 g |
Weight per piece (excluding packing) | 152.86 g |
Customs tariff number | 85371098 |
Country of origin | DE |
Note on application | |
Note on application | Only for industrial use |
Product type | Safety relays |
Product family | PSRclassic |
Application | Emergency stop |
Process technology | |
Safety door | |
Control | 1-channel |
Mechanical service life | approx. 107 cycles |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Insulation characteristics | |
Overvoltage category | III |
Degree of pollution | 2 |
Times | |
Typical response time | typ. 60 ms (For Us manual, monitored start) |
60 ms (For Us autostart) | |
Typ. starting time with Us | 60 ms (At Us/on demand via A1) |
Typical release time | typ. 20 ms (At Us/on demand via A1) |
Restart time | < 1 s (Boot time) |
Recovery time | ≥ 1 s (following demand of the safety function) |
Start pulse length | ≥ 500 ms (manual start) |
Maximum power dissipation for nominal condition | 16.12 W (At US = 26.4 V, IL² = 72 A², PTotal max= 1.72 W + 14.4 W) |
Nominal operating mode | 100% operating factor |
Rated insulation voltage | 250 V |
Rated surge voltage/insulation | See section “Insulation coordination” |
Digital: Logic (A1) | |
Description of the input | safety-related |
Number of inputs | 1 |
Input voltage range “1” signal | 20.4 V … 26.4 V |
Inrush current | max. 1 A (typ. with US, Δt = < 10 ms) |
Filter time | max. 3 ms (Test pulse width of low test pulses) |
min. 200 ms (Test pulse rate for low test pulse) | |
No brightness test pulses / high test pulses permitted. | |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 65 mA (typ. with US) |
Digital: Start circuit (Y2) | |
Description of the input | non-safety-related |
Number of inputs | 1 |
Input voltage range “1” signal | 20.4 V … 26.4 V |
Inrush current | < 14 mA (typ. with US at Y2, Δt – 10 ms) |
Filter time | No test pulses permitted |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 0 mA (typ. with US at Y2) |
Relay: Enabling current paths (13/14, 23/24) | |
Output description | 2 N/O contacts each in series, safety-related, floating |
Number of outputs | 2 |
Contact switching type | 2 enabling current paths |
Contact material | AgSnO2 |
Switching voltage | min. 10 V |
max. 250 V AC/DC | |
Switching capacity | min. 100 mW |
Inrush current | min. 10 mA |
max. 6 A | |
Limiting continuous current | 6 A (Observe derating and load limit curve) |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 107 cycles |
Interrupting rating (ohmic load) max. | Observe derating and load limit curve |
Maximum interrupting rating (inductive load) | Observe derating and load limit curve |
Output fuse | 10 A gL/gG |
4 A gL/gG (for low-demand applications) | |
Relay: Signaling current path (31/32) | |
Output description | 2 N/C contacts parallel, non-safety-related, floating |
Number of outputs | 1 |
Contact switching type | 1 signaling current path |
Contact material | AgSnO2 |
Switching voltage | min. 10 V AC/DC |
max. 250 V AC/DC | |
Switching capacity | min. 100 mW |
Inrush current | min. 10 mA |
max. 6 A | |
Limiting continuous current | 6 A |
Sq. Total current | 36 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 107 cycles |
Interrupting rating (ohmic load) max. | Observe derating and load limit curve |
Maximum interrupting rating (inductive load) | Observe derating and load limit curve |
Output fuse | 6 A gL/gG |
Connection technology | |
pluggable | yes |
Conductor connection | |
Connection method | Screw connection |
Conductor cross section rigid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross-section AWG | 24 … 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Status display | LED (green) |
Operating voltage display | Green LED |
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Color (Housing) | yellow (RAL 1018) |
Housing material | PA |
Safety data | |
Stop category | 0 |
Safety data: EN ISO 13849 | |
Category | 4 |
Performance level (PL) | e |
Safety data: IEC 61508 – High demand | |
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 – Low demand | |
Safety Integrity Level (SIL) | 3 |
Safety data: EN IEC 62061 | |
Safety Integrity Level (SIL) | 3 |
Ambient conditions | |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient temperature (operation) | -20 °C … 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C … 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (operation) | 10 Hz … 150 Hz, 2g |
CE | |
Identification | CE-compliant |
Mounting type | DIN rail mounting |
Mounting position | On horizontal and vertical DIN rail |
Weight | 0.18305 kg |
---|---|
Dimensions | 11.45 × 2.25 × 9.9 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)