QUINT-PS/24DC/48DC/ 5 – 2320128 – Phoenix Contact DC/DC Converters
USD 409.50
Inosaki – Your Trusted Phoenix Contact Distributor
Inosaki proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.
Our Best-Selling Terminal Blocks: Feed-Through, Fuse Modular, Spring Cage, Double Level, Multi-Level
Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.
Reliable Power Supply Solutions
Discover industry-leading Phoenix Contact power supplies, such as:
- QUINT Power – Premium performance for critical systems
- STEP Power – Compact design for space-saving applications
- Trio Power – Rugged and reliable for industrial needs
- UNO Power – Cost-effective and efficient
Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@inosaki.com to request your Phoenix Contact catalog.
Product Description
MINI DC/DC converter for MCR technology.
DC/DC converters alter the voltage level, regenerate the voltage at the end of long cables or enable the creation of independent supply systems by means of electrical isolation.
Commercial Data
| Item number |
2320128 |
| Packing unit |
1 pc |
| Minimum order quantity |
1 pc |
| Product key |
CMDQ44 |
| Catalog page |
Page 249 (C-4-2017) |
| GTIN |
4046356481908 |
| Weight per piece (including packing) |
1,095.8 g |
| Weight per piece (excluding packing) |
900 g |
| Customs tariff number |
85044095 |
| Country of origin |
IN |
Product Properties
| Product type |
DC/DC converters |
| MTBF (IEC 61709, SN 29500) |
> 761000 h (40 °C) |
| Insulation characteristics |
| Protection class |
III |
| Degree of pollution |
2 |
Electrical Properties
| Number of phases |
1.00 |
| Insulation voltage input/output |
1.5 kV (type test) |
| 1 kV (routine test) |
| 1 kV (type test) |
Input Data
| DC operation |
| Nominal input voltage range |
24 V DC |
| Input voltage range |
18 V DC … 32 V DC |
| Extended input voltage range in operation |
14 V DC … 18 V DC (Derating) |
| Wide-range input |
no |
| Input voltage range DC |
18 V DC … 32 V DC |
| 14 V DC … 18 V DC (Consider derating during operation) |
| Voltage type of supply voltage |
DC |
| Inrush current |
< 15 A (typical) |
| Inrush current integral (I2t) |
3 A2s |
| Mains buffering time |
> 12 ms (24 V DC) |
| Current consumption |
14 A (24 V, IBOOST) |
| Reverse polarity protection |
≤ yes30 V DC |
| Protective circuit |
Transient surge protection; Varistor |
| Input fuse |
25 A (internal (device protection)) |
Output Data
| Efficiency |
> 92.5 % |
| Output characteristic |
U/I |
| Nominal output voltage |
48 V DC ±1 % |
| Setting range of the output voltage (USet) |
30 V DC … 56 V DC (> 48 V DC, constant capacity restricted) |
| Nominal output current (IN) |
5 A (-25 °C … 60 °C) |
| POWER BOOST (IBoost) |
6.25 A (-25 °C … 40 °C permanent, UOUT = 48 V DC ) |
| Selective Fuse Breaking (ISFB) |
30 A (12 ms) |
| Magnetic circuit breaker tripping |
B2 / B4 / C2 |
| Derating |
60 °C … 70 °C (2.5 %/K) |
| Feedback voltage resistance |
60 V DC |
| Protection against overvoltage at the output (OVP) |
< 60 V DC |
| Max. capacitive load |
unlimited |
| Active current limitation |
Approximately 7 A |
| Control deviation |
< 1 % (change in load, static 10 % … 90 %) |
| < 2 % (change in load, dynamic 10 % … 90 %) |
| < 0.1 % (change in input voltage ±10 %) |
| Residual ripple |
< 20 mVPP |
| Short-circuit-proof |
yes |
| Output power |
240 W |
| Peak switching voltages nominal load |
< 10 mVPP (20 MHz) |
| Maximum no-load power dissipation |
5.2 W |
| Power loss nominal load max. |
21 W |
| Rise time |
< 2 ms (UOUT (10 % … 90 %)) |
| Connection in parallel |
yes, for redundancy and increased capacity |
| Connection in series |
yes |
| Signal: DC OK active |
| Output description |
UOUT > 0.9 x UN: High signal |
| Switching voltage range |
24 V DC |
| Maximum inrush current |
< 20 mA (short-circuit-proof) |
| Signal: POWER BOOST, active |
| Output description |
IOUT < IN: High signal |
| Switching voltage range |
24 V DC |
| Maximum inrush current |
< 20 mA (short-circuit-proof) |
| Signal: UIN OK, active |
| Output description |
UIN > 19.2 V: High signal |
| Switching voltage range |
24 V DC |
| Maximum inrush current |
≤ 20 mA (short-circuit-proof) |
| Signal: DC OK floating |
| Output description |
Relay |
| Output voltage |
≤ 30 V AC/DC |
| Maximum inrush current |
≤ 100 mA |
Connection Data
| Input |
| Connection method |
Pluggable screw connection |
| Conductor cross section, rigid min. |
0.2 mm² |
| Conductor cross section, rigid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
12 |
| Stripping length |
8 mm |
| Screw thread |
M3 |
| Tightening torque, min |
0.5 Nm |
| Tightening torque max |
0.6 Nm |
| Output |
| Connection method |
Pluggable screw connection |
| Conductor cross section, rigid min. |
0.2 mm² |
| Conductor cross section, rigid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
12 |
| Stripping length |
7 mm |
| Screw thread |
M3 |
| Tightening torque, min |
0.5 Nm |
| Tightening torque max |
0.6 Nm |
| Signal |
| Conductor cross section, rigid min. |
0.2 mm² |
| Conductor cross section, rigid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
12 |
| Screw thread |
M3 |
| Tightening torque, min |
0.5 Nm |
| Tightening torque max |
0.6 Nm |
Signaling
| Types of signaling |
LED |
| Active switching output |
| Relay contact |
| Signal output: DC OK active |
| Status display |
“DC OK” LED green |
| Color |
green |
| Signal output: POWER BOOST, active |
| Status display |
“BOOST” LED yellow/IOUT > IN : LED on |
| Color |
yellow |
| Note on status display |
LED on |
| Signal output: UIN OK, active |
| Status display |
LED “UIN < 19.2 V” yellow/UIN < 19.2 V DC: LED on |
| Color |
yellow |
| Note on status display |
LED on |
| Signal output: DC OK floating |
| Note on status display |
UOUT > 0.9 x UN: Contact closed |
Dimension
| Width |
48 mm |
| Height |
130 mm |
| Depth |
125 mm |
| Installation dimensions |
| Installation distance right/left |
0 mm / 0 mm (≤ 70 °C) |
| Installation distance right/left (active) |
15 mm / 15 mm (≤ 70 °C) |
| Installation distance top/bottom |
50 mm / 50 mm (≤ 70 °C) |
| Installation distance top/bottom (active) |
50 mm / 50 mm (≤ 70 °C) |
| Alternative assembly |
| Width |
122 mm |
| Height |
130 mm |
| Depth |
51 mm |
Material Specifications
| Housing material |
Metal |
| Type of housing |
Aluminum (AlMg3) |
| Hood version |
Galvanized sheet steel, free from chrome (VI) |
Environmental and real-life conditions
| Ambient conditions |
| Degree of protection |
IP20 |
| Ambient temperature (operation) |
-25 °C … 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested) |
| Ambient temperature (storage/transport) |
-40 °C … 85 °C |
| Ambient temperature (start-up type tested) |
-40 °C |
| Climatic class |
3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
| Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| 15 Hz … 150 Hz, 2.3g, 90 min. |
| Temp code |
T4 (-25 … +70 °C; > 60 °C, Derating: 2,5 %/K) |
Standards And Regulations
| Rail applications |
EN 50121-4 |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
| Standard – Electrical safety |
EN 60950-1/VDE 0805 (SELV) |
| Standard – Safety extra-low voltage |
EN 60950-1 (SELV) |
| EN 60204 (PELV) |
| Standard – Safe isolation |
DIN VDE 0100-410 |
| Fire protection in rail vehicles |
| Standard designation |
Fire protection in rail vehicles |
| Standards/specifications |
EN 45545-2 (HL3) |
Approvals
| Shipbuilding approval |
DNV GL (EMC B) |
| UL approvals |
UL/C-UL listed UL 508 |
| UL/C-UL Recognized UL 60950-1 |
| UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
EMC Data
| Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
| EMC requirements for noise emission |
EN 61000-6-3 |
| EN 61000-6-4 |
| EMC requirements for noise immunity |
EN 61000-6-1 |
| EN 61000-6-2 |
| Electrostatic discharge |
| Standards/regulations |
EN 61000-4-2 |
| Electrostatic discharge |
| Contact discharge |
8 kV (Test Level 4) |
| Discharge in air |
15 kV (Test Level 4) |
| Comments |
Criterion A |
| Electromagnetic HF field |
| Standards/regulations |
EN 61000-4-3 |
| Electromagnetic HF field |
| Frequency range |
80 MHz … 1 GHz |
| Test field strength |
10 V/m |
| Frequency range |
1.4 GHz … 2 GHz |
| Test field strength |
10 V/m |
| Frequency range |
2 GHz … 3 GHz |
| Test field strength |
10 V/m |
| Comments |
Criterion A |
| Fast transients (burst) |
| Standards/regulations |
EN 61000-4-4 |
| Fast transients (burst) |
| Input |
2 kV (Test Level 3 – asymmetrical) |
| Output |
2 kV (Test Level 3 – asymmetrical) |
| Signal |
2 kV (Test Level 4 – asymmetrical) |
| Comments |
Criterion A |
| Surge voltage load (surge) |
| Standards/regulations |
EN 61000-4-5 |
| Surge voltage load (surge) |
| Input |
0.5 kV (Test Level 1 – symmetrical) |
| 0.5 kV (Test Level 1 – asymmetrical) |
| Output |
0.5 kV (Test Level 1 – symmetrical) |
| 0.5 kV (Test Level 1 – asymmetrical) |
| Signal |
1 kV (Test Level 2 – asymmetrical) |
| Comments |
Criterion B |
| Conducted interference |
| Standards/regulations |
EN 61000-4-6 |
| Conducted interference |
| Input/output/signal |
asymmetrical |
| Frequency range |
0.15 MHz … 80 MHz |
| Comments |
Criterion A |
| Voltage |
10 V (Test Level 3) |
| Emitted interference |
| Standards/regulations |
EN 61000-6-3 |
| Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Criteria |
| Criterion A |
Normal operating behavior within the specified limits. |
| Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Mounting
| Mounting type |
DIN rail mounting |
| Assembly note |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
| Mounting position |
horizontal DIN rail NS 35, EN 60715 |
| With protective coating |
no |