Skip to content

Contact Us:
sales@inosaki.com

SICK 1059410 RE11-SAC Magnetic Safety Switch with Actuator

SICK 1059410 RE11-SAC Magnetic Safety Switch with Actuator

USD 73.84

RE11-SAC is a magnetic safety switch with actuator, one N/O and one N/C reed contact, 3 mm assured switch-on distance and an M8 four-pin connection.

SKU: SICK-1059410 Category:
SICK Safety Switches

SICK RE11-SAC Magnetic Safety Switch with Actuator

BrandSICK
Model IdentifierRE11-SAC
Official Part Number1059410

Technical Overview

The SICK RE11-SAC is a magnetic non-contact safety switch supplied as a sensor with actuator. One normally open and one normally closed reed contact provide separate switching paths, with a 3 mm assured switch-on distance and 12 mm assured switch-off distance. It is a type 4 device with low actuator coding to EN ISO 14119, one active sensor surface and five actuation directions. Connected safety-related logic must evaluate the individually wired contacts and perform fault detection; the switch has no internal fault detection and cannot assume a safe state on a fault by itself. The M8 four-pin connection uses a nickel-plated brass coupling nut, while the VISTAL housing is rated IP67.

Magnetic safety switch with actuator, one N/O and one N/C reed contact, 3 mm assured switch-on distance, 12 mm assured switch-off distance and M8 connection.

Key Features

  • Magnetic non-contact safety switch supplied as sensor with actuator
  • One N/O and one N/C reed contact; no signaling contacts
  • Assured switch-on distance Sao 3 mm; switch-off distance Sar 12 mm
  • Type 4; low coding level to EN ISO 14119
  • One active sensor surface; five actuation directions
  • B10d 2 × 10⁷ switching cycles at small load
  • No internal fault detection; connected safety-related logic performs diagnostics
  • Individual wiring with diagnostics; no safe series connection
  • M8 four-pin plug; switching voltage ≤30 V DC and current ≤400 mA
  • IP67 VISTAL housing; −30 to +60 °C operating and storage temperature

Provide separate N/O and N/C actuator-position contacts to compatible safety-related logic, with individual wiring and external fault diagnostics.

Technical Specification Matrix

ParameterValue
Product configurationMagnetic non-contact safety switch; sensor with actuator
Safety contactsOne normally open and one normally closed reed contact
Signaling contactsNone
Assured operating distance Sao3 mm
Assured release distance Sar12 mm
Active sensor surfaces1
Actuation directions5
Device typeType 4, EN ISO 14119
Coding levelLow coding, EN ISO 14119
Fault detectionNo internal fault detection; connected safety-related logic must detect faults; the switch cannot assume a safe state on a fault by itself
Wiring arrangementIndividual wiring with diagnostics; no safe series connection
B10d2 × 10⁷ switching cycles at small load
ConnectionM8 four-pin plug
Contact pin assignmentN/O contact: 1 BN–2 WH; N/C contact: 3 BU–4 BK
Contact sequenceManufacturer timing diagram shows sequential N/O and N/C contact behavior; external safety-related logic must evaluate the documented sequence
Coupling nut materialNickel-plated brass
Maximum switching voltage30 V DC
Maximum switching current400 mA
Housing materialVISTAL
IP ratingIP67, IEC 60529
Operating temperature−30 to +60 °C
Storage temperature−30 to +60 °C
Vibration resistance10–55 Hz, amplitude 1 mm, EN 60947-5-3
Shock resistance30 g, 11 ms, EN 60947-5-3
Mounting holesØ4.5 mm with Ø8.5 mm counterbores; 22 mm center spacing

Industrial Applications

1. Monitoring opening of a hinged guard

A hinged guard can carry the matching actuator so it approaches the sensor when the guard closes. Opening the guard separates the actuator and changes the N/O and N/C contact paths. Connected safety-related logic evaluates both individually wired paths and performs fault detection, with alignment, assured distances and the machine stop response verified as part of the complete interlocking design.

Problem Solved

An actuator-position reference helps connected safety-related logic recognize an opened guard and apply the machine response defined for that interlock, with diagnostics provided externally.

Guard position Magnetic actuator External diagnostics

2. Checking a removable guard before restart

A removable guard can carry the matching actuator so its refitted position presents the documented contact pattern within the assured switch-on distance. Connected safety-related logic checks the N/O and N/C paths individually before accepting the machine’s restart condition. Commissioning verifies actuator alignment, withdrawal behavior, low coding and the complete interlocking arrangement for the actual access point.

Problem Solved

A guard-present reference helps the connected safety-related logic check the refitted condition before restart, using separate contact paths and external fault detection for the validated arrangement.

Removable guard Restart condition Contact evaluation

3. Checking contact sequence during interlock commissioning

During interlock commissioning, the sensor’s N/O and N/C contacts can be wired individually to compatible safety-related logic and exercised through actuator approach and withdrawal. The logic evaluates the manufacturer’s documented switching sequence and checks inconsistent states. The switch itself provides no internal fault detection, so the external circuit and complete installation must implement and validate the required diagnostic behavior.

Problem Solved

Separate contact feedback supports checking interlock behavior during setup, with the connected safety-related logic responsible for recognizing faults and enforcing the intended machine response.

Contact sequence Commissioning Individual wiring