SICK 1059503 RE13-SAC Magnetic Safety Switch with Actuator

SICK 1059503 RE13-SAC Magnetic Safety Switch with Actuator

USD 79.04

RE13-SAC is a magnetic non-contact safety switch with actuator, two N/O reed contacts, 7 mm assured operating distance and an M8 four-pin connection.

SKU: SICK-1059503 Category:
SICK Safety Switches

SICK RE13-SAC Magnetic Safety Switch with Actuator

BrandSICK
Model IdentifierRE13-SAC
Official Part Number1059503

Technical Overview

The SICK RE13-SAC is a magnetic non-contact safety switch supplied as a sensor with actuator. Two normally open reed contacts provide the switching paths, with an assured operating distance of 7 mm and assured release distance of 20 mm. It is a type 4 device with low coding to EN ISO 14119, one active sensor surface and five actuation directions. The switch has no internal fault detection; connected safety-related logic must perform fault detection using the individual wiring and diagnostics. Safe series connection is not provided. An M8 four-pin plug connects the contacts, while the VISTAL housing provides IP67 protection and operation from −30 to +60 °C.

Magnetic non-contact safety switch with actuator, two N/O reed contacts, 7 mm assured operating distance, 20 mm assured release distance and M8 connection.

Key Features

  • Magnetic non-contact safety switch supplied with actuator
  • Two normally open reed contacts; no normally closed or signaling contacts
  • Assured operating distance Sao 7 mm; assured release distance Sar 20 mm
  • Type 4 and low coding to EN ISO 14119
  • One active sensor surface; five actuation directions
  • No internal fault detection; requires connected safety-related logic for diagnostics
  • Individual wiring with diagnostics; no safe series connection
  • M8 four-pin plug; nickel-plated brass coupling nut
  • Maximum switching voltage 30 V DC; maximum switching current 100 mA
  • VISTAL housing; IP67; −30 to +60 °C operating and storage temperature

Monitor the matching actuator through two N/O reed contacts, with individual wiring and fault diagnostics performed by connected safety-related logic.

Technical Specification Matrix

ParameterValue
Product configurationMagnetic non-contact safety switch; sensor with actuator
Safety contactsTwo normally open reed contacts; zero normally closed contacts
Signaling contactsNone
Assured operating distance Sao7 mm
Assured release distance Sar20 mm
Active sensor surfaces1
Actuation directions5
Device typeType 4, EN ISO 14119
Coding levelLow coding, EN ISO 14119
Fault detectionNo internal fault detection; connected safety-related logic must detect faults; the switch cannot assume a safe state on a fault by itself
Wiring arrangementIndividual wiring with diagnostics; no safe series connection
B10d2 × 10⁷ switching cycles at small load
ConnectionM8 four-pin plug
Contact pin assignmentN/O contact: 1 BN–2 WH; second N/O contact: 3 BU–4 BK
Contact sequenceManufacturer diagram shows the two N/O contacts closing and opening in sequence; external logic monitors both contacts
Coupling nut materialNickel-plated brass
Maximum switching voltage30 V DC
Maximum switching current100 mA
Housing materialVISTAL
IP ratingIP67, IEC 60529
Operating temperature−30 to +60 °C
Storage temperature−30 to +60 °C
Vibration resistance10–55 Hz, amplitude 1 mm, EN 60947-5-3
Shock resistance30 g, 11 ms, EN 60947-5-3
Mounting holesØ4.5 mm with Ø8.5 mm counterbores; 22 mm center spacing

Industrial Applications

1. Monitoring opening of a hinged guard

A hinged guard can carry the matching actuator so it enters the sensor’s operating region when the guard is closed. Opening the guard separates the actuator and changes the two reed-contact paths. Connected safety-related logic evaluates those contacts and performs fault diagnostics, with the machine’s stop response established by the complete interlocking design and validated installation.

Problem Solved

A guard-position input helps the connected safety-related logic recognize an opened access guard and initiate the machine response defined for that interlock, with external fault detection.

Hinged guard Actuator separation External safety logic

2. Checking that a removable guard is refitted

A removable guard can carry the matching actuator so the sensor’s two N/O contacts close only when the guard is presented within the intended operating region. Connected safety-related logic checks the individually wired contacts before accepting a restart condition. Installation verifies actuator alignment, operating and release distances, low coding and the complete interlocking arrangement for the actual guard.

Problem Solved

A guard-present input helps connected safety-related logic check that a removable guard has been refitted before restart, using both contact paths and the required external diagnostics.

Removable guard Restart condition Individual wiring

3. Checking two-contact behavior in an interlock circuit

An interlocking circuit can connect the two N/O contact paths individually to compatible safety-related logic. During actuator approach and withdrawal, the controller evaluates the contact states and their expected sequence using the manufacturer’s switching diagram. Fault recognition belongs to that external logic; the switch itself has no internal fault detection and safe series connection is not provided.

Problem Solved

Individual contact feedback gives connected safety-related logic a basis for diagnosing inconsistent interlock behavior, rather than relying on a single combined contact state from the guard.

Contact diagnostics Switching sequence External monitoring