Sale!

Festo 9686 Quick Exhaust Valve, G1/4, 1200 l/min Exhaust

Original price was: USD 63.96.Current price is: USD 55.64.

G1/4 quick-exhaust valve with 1200 l/min exhaust and 960 l/min feed nominal flow at 6→5 bar, 0.5–10 bar operation and 100 g product weight.

SKU Festo-9686 Category
Festo Quick Exhaust Valves

Festo SE-1/4-B Quick Exhaust Valve

BrandFesto
Model IdentifierSE-1/4-B
Official Part Number9686

Technical Overview

The Festo SE-1/4-B is a screw-in quick-exhaust valve with G1/4 supply, working and exhaust connections and a 7 mm nominal size. Supply air passes toward the actuator while the exhaust port is closed; when supply pressure falls, the working port exhausts locally through port 3. The exact valve provides 1200 l/min nominal exhaust flow and 960 l/min nominal feed flow, both specified at 6-to-5 bar conditions. The 100 g die-cast zinc assembly uses NBR seals and operates over 0.5–10 bar. Any mounting position and a −20 to 75 °C ambient/media range support installation at the actuator port for the documented quick-exhaust function.

G1/4 quick-exhaust valve with 1200 l/min nominal exhaust flow at 6→5 bar, 7 mm nominal size and 100 g product weight.

Key Features

  • Quick-exhaust function with local working-port exhaust
  • G1/4 connections at ports 1, 2 and 3
  • 1200 l/min standard nominal exhaust flow at 6→5 bar
  • 960 l/min standard nominal feed flow at 6→5 bar
  • 7 mm nominal size
  • 0.5–10 bar operating-pressure range
  • Screw-in mounting in any position
  • Die-cast zinc housing with NBR seals
  • 100 g product weight; −20 to 75 °C ambient/media range

Exhaust a pneumatic actuator locally through a G1/4 quick-exhaust valve rated for 1200 l/min nominal exhaust flow at 6→5 bar.

Technical Specification Matrix

ParameterValue
Valve functionQuick exhaust
Pneumatic connection, port 1G1/4
Pneumatic connection, port 2G1/4
Type of mountingScrew-in
Standard nominal exhaust flow at 6→5 bar1200 l/min
Standard nominal feed flow at 6→5 bar960 l/min
Operating pressure0.5 bar...10 bar
Ambient temperature-20 °C...75 °C
Material housingDie-cast zinc
Operating mediumCompressed air to ISO 8573-1:2010 [7:-:-]
Nominal size7 mm
Mounting positionAny
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-20 °C...75 °C
Physical Weight (kg)0.1
Pneumatic connection, port 3G1/4
Material sealsNBR

Industrial Applications

1. Local Exhaust for Spring-return Cylinder Retraction

A single-acting cylinder must return under spring force after its air command is removed. Mounted at the actuator port, the quick-exhaust valve routes air from the cylinder directly to its local exhaust as supply pressure falls. Its G1/4 connections and 1200 l/min nominal exhaust rating at 6-to-5 bar define the component interface and flow characteristic for evaluating the return circuit.

Problem Solved

A local exhaust path lets the spring-return chamber discharge at the actuator, avoiding the need for that air to return through the full upstream control line.

Local actuator exhaust G1/4 1200 l/min exhaust at 6→5 bar

2. Exhausting the Opposing Chamber of a Double-acting Drive

A double-acting cylinder fills one chamber while the opposite chamber needs to exhaust during the commanded stroke. A quick-exhaust valve at the selected chamber provides a local discharge route when its supply-line pressure drops. This G1/4 version separates its 960 l/min feed and 1200 l/min exhaust ratings, giving specific data for evaluating both phases of that chamber's pneumatic operation.

Problem Solved

The valve combines chamber filling and local exhaust routing, supplying a defined discharge path for the opposing chamber while retaining the normal feed connection.

Feed/exhaust routing 960 l/min feed at 6→5 bar Local discharge

3. Actuator Exhaust with a Remote Directional Valve

A machine layout places its directional control valve away from the actuator, creating a longer control-line route for exhaust air. Installing the quick-exhaust valve directly at the actuator provides the manufacturer-described local discharge path through port 3. Screw-in G1/4 mounting and any-position installation support that placement, with separate flow data for the supply and exhaust paths.

Problem Solved

Local exhaust routing bypasses the remote directional-valve return path for actuator discharge, allowing the pneumatic layout to keep its control valve remote while exhausting at the drive.

Remote control-valve layout Screw-in mounting G1/4 exhaust port