Skip to content

Contact Us:
sales@inosaki.com

SICK 1037625 AFS60E-S1AA004096 12-bit SSI Absolute Encoder

SICK 1037625 AFS60E-S1AA004096 12-bit SSI Absolute Encoder

USD 415.48

AFS60E-S1AA004096 provides 4,096-step Gray-code SSI feedback, 6 mm × 10 mm solid shaft, radial M23 connector and electronic SET adjustment.

SKU: SICK-1037625 Category:
SICK Encoders

SICK AFS60E-S1AA004096 12-bit SSI Absolute Encoder

BrandSICK
Model IdentifierAFS60E-S1AA004096
Official Part Number1037625

Technical Overview

The SICK AFS60E-S1AA004096 is an absolute rotary encoder with 4,096 steps per revolution and 12-bit Gray-code position data over SSI. Its solid 6 mm × 10 mm shaft uses a servo flange, while a radial M23 12-pin male connector carries the interface and control signals. Position forming takes less than 1 µs, valid data is available after a 50 ms initialization period, and the clock frequency is up to 1 MHz. An H-active SET input provides electronic adjustment and a separate input selects CW/CCW counting. The 4.5–32 V DC device consumes no more than 0.7 W without load and combines a stainless steel shaft, aluminum flange and die-cast aluminum housing.

4,096-step, 12-bit SSI absolute encoder with servo flange, 6 mm × 10 mm solid shaft and radial M23 12-pin male connector.

Key Features

  • Absolute rotary position measurement; 4,096 steps per revolution
  • 12-bit Gray-code SSI interface
  • Clock frequency ≤1 MHz; Clock+ LOW time at least 250 ns
  • <1 µs position forming; 50 ms initialization
  • H-active electronic SET and L-active CW/CCW input
  • Solid 6 mm × 10 mm shaft with servo flange
  • Radial M23 12-pin male connector
  • 4.5–32 V DC; ≤0.7 W without load; reverse-polarity protection
  • Stainless steel shaft, aluminum flange and die-cast aluminum housing
  • IP65 shaft side; IP67 housing side with mating connector installed

Provide absolute shaft-angle data and electronic reference adjustment to external indexing, speed-evaluation and phase-control logic.

Technical Specification Matrix

ParameterValue
Functional principleAbsolute rotary position measurement
Resolution4,096 steps per revolution; 12 bit
Error limits G0.2° according to DIN ISO 1319-1; symmetrical upper/lower limit position depends on installation
Repeatability standard deviation0.002° according to DIN ISO 55350-13; 68.3% of values within the specified interval
Communication interfaceSSI
Code typeGray
Initialization time50 ms before valid position data can be read
Position forming time<1 µs
Clock frequency≤1 MHz; minimum LOW level at Clock+ is 250 ns
Counting sequenceCW/CCW adjustable through V/R̅ input
SET inputElectronic adjustment; H-active; LOW=0–3 V; HIGH=4.0 V to supply voltage
CW/CCW inputL-active; LOW=0–1.5 V; HIGH=2.0 V to supply voltage
Connectionradial M23 12-pin male connector
Power supply4.5–32 V DC
Power consumption≤0.7 W without load
Reverse-polarity protectionProvided
MTTFD250 years according to EN ISO 13849-1; standard product, not a safety component; nominal component loading, 40 °C average ambient, 8,760 h/year
Mechanical designSolid shaft, servo flange
Shaft diameter6 mm
Shaft length10 mm
Shaft materialStainless steel
Flange materialAluminum
Housing materialAluminum die cast
Start-up torque<0.5 Ncm at +20 °C
Operating torque<0.3 Ncm at +20 °C
Permissible shaft load80 N radial; 40 N axial
Operating speed≤9,000 rpm; account for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range
Rotor moment of inertia6.2 gcm²
Bearing lifetime3.0 × 10⁹ revolutions
Angular acceleration≤500,000 rad/s²
IP ratingIP65 shaft side; IP67 housing side according to IEC 60529; connector version requires mounted mating connector
Permissible relative humidity90%; condensation not permitted
Operating temperature0 to +85 °C; account for speed-related self-heating
Storage temperature−40 to +100 °C without packaging
Shock resistance50 g, 6 ms according to EN 60068-2-27
Vibration resistance20 g, 10–2,000 Hz according to EN 60068-2-6
EMCEN 61000-6-2 and EN 61000-6-3 when using shielded cables
ShieldingShield connected to housing on encoder side and ground on control side
Shaft characteristicWith flat
Pin assignment1=GND; 2=Data+; 3=Clock+; 4/5/6/7=not assigned; 8=supply; 9=SET; 10=Data−; 11=Clock−; 12=V/R̅
Physical Weight (kg)0.3

Industrial Applications

1. Referencing angular position on a rotary indexing table

A rotary indexing table can couple the encoder shaft to its rotating mechanism and read 4,096 Gray-code positions per revolution through an SSI master. External motion logic compares the measured angle with the required station position. Mechanical integration uses the servo flange and 6 mm × 10 mm shaft, with installed accuracy evaluated against the documented error limits and repeatability.

Problem Solved

Absolute angle readings give indexing logic a position reference for each station, helping coordinate table presentation without deriving angle solely from a count of switching events.

Rotary indexing 12-bit angle SSI

2. Evaluating roller speed in external process control

A process roller can drive the encoder through a suitable mechanical coupling while an external SSI master samples successive angular positions. The controller handles angle wraparound and calculates speed from the measured position change and elapsed time. Sample timing is coordinated with the SSI clock limit, position-forming time and the actual operating speed, including speed-related self-heating.

Problem Solved

Successive angular readings supply external speed calculation with measured motion, helping process control compare roller travel with the commanded running condition during each sampling interval.

Roller speed External calculation Angular sampling

3. Establishing a machine-phase reference during setup

During machine setup, an operator can position a shaft at the required reference and invoke the H-active SET input for electronic adjustment. The CW/CCW input sets the counting sequence to suit the installed orientation. External sequencing logic then uses the absolute SSI position to define phase windows for subsequent machine operations within the shaft cycle.

Problem Solved

Electronic adjustment and selectable counting direction align the measured phase with the machine sequence, helping reuse a mechanical reference when commissioning or changing the installed orientation.

Electronic SET CW/CCW Phase setup
Select your currency