Skip to content

Contact Us:
sales@inosaki.com

SICK 1036787 DFS60B-BHPK10000 Programmable Incremental Encoder

SICK 1036787 DFS60B-BHPK10000 Programmable Incremental Encoder

USD 587.08

DFS60B-BHPK10000 provides 10,000 pulses/revolution, programmable TTL/HTL with factory TTL, a 15 mm blind hollow shaft, front clamp and 1.5 m cable.

SKU: SICK-1036787 Category:
SICK Encoders

SICK DFS60B-BHPK10000 Programmable Incremental Encoder

BrandSICK
Model IdentifierDFS60B-BHPK10000
Official Part Number1036787

Technical Overview

The SICK DFS60B-BHPK10000 is a programmable incremental encoder configured for 10,000 pulses per revolution, with a 15 mm blind hollow shaft and front clamp. Its six-channel TTL/HTL interface is factory-set to TTL and provides A, B and reference signals with their complements. The universal 1.5 m eight-wire cable can be routed axially or radially without a bend at the connection. Supply is 4.5–32 V, output frequency is no more than 600 kHz and load current is no more than 30 mA. Construction combines a stainless steel shaft, aluminum flange, die-cast aluminum housing and IP67 protection on the housing/cable side and IP65 on the shaft side. Operation reaches 6,000 rpm with the specified thermal allowance; cable movement determines the lower operating-temperature limit.

10,000-pulse programmable TTL/HTL incremental encoder with factory TTL, 15 mm blind hollow shaft, front clamp and 1.5 m universal cable.

Key Features

  • 10,000 pulses per revolution; ±0.05° error limits
  • Six-channel incremental TTL/HTL interface; factory output level TTL
  • A/B/Z signals and their complements; one reference signal gated with A and B at 90° electrical
  • Programmable electrical zero-pulse widths 90°, 180° or 270°; mechanical width 1°–359°
  • 15 mm blind hollow stainless steel shaft with front clamp
  • 1.5 m eight-wire universal cable; axial or radial routing without a bend at the connection
  • 4.5–32 V supply; ≤0.7 W without load; output frequency ≤600 kHz
  • Operating speed ≤6,000 rpm; allow 3.3 K self-heating per 1,000 rpm
  • IP67 housing/cable side; IP65 shaft side; aluminum flange and die-cast aluminum housing
  • Operating temperature −40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable

Provide pulse, direction and once-per-revolution reference information to external motion control, with programmable TTL/HTL signaling and a hollow-shaft mounting configuration.

Technical Specification Matrix

ParameterValue
Encoder typeIncremental rotary encoder
Pulses per revolution10,000; observe maximum-revolution operating range
Measuring step90° electrical / pulses per revolution, manufacturer specification
Non-binary measuring-step deviation±0.01°
Error limits±0.05°
Electrical interfaceTTL/HTL, programmable/configurable
Factory output levelTTL
Signal channelsSix: A, A̅, B, B̅, Z, Z̅
Reference signalOne; 90° electrical, logically gated with A and B
Electrical zero-pulse configuration90° gated with A and B; 180° gated with B; 180° gated with A; 270° gated with A or B
Mechanical zero-pulse widthProgrammable 1°–359° relative to one mechanical shaft revolution
Initialization time32 ms; 30 ms with mechanical zero-pulse width
Output frequency≤600 kHz
Load current≤30 mA
Power consumption≤0.7 W without load
Power supply4.5–32 V
Reverse-polarity protectionYes
Output short-circuit protectionMaximum 30 s: TTL at supply ≥5.5 V against another channel or GND; HTL or TTL at supply <5.5 V against another channel, supply or GND
Connection1.5 m universal eight-wire cable; positioned for radial or axial routing without bends at the connection
Conductor functionsWH=A; BN=A̅; PK=B; BK=B̅; VT=Z; YE=Z̅; BU=GND; RD=+Us
Screen connectionConnected to encoder housing on encoder side; connect to ground on control side
Cable diameter5.6 ±0.2 mm
Cable bend radius30 mm
Mechanical designBlind hollow shaft
Shaft diameter15 mm, F7 bore; customer shaft j7
ClampingFront clamp
Customer shaft engagementMinimum 15 mm; maximum 42 mm insertion shown
Shaft materialStainless steel
Flange materialAluminum
Housing materialAluminum die cast
Start-up torque0.8 Ncm at +20 °C
Operating torque0.6 Ncm at +20 °C
Permissible static movement±0.3 mm radial; ±0.5 mm axial
Permissible dynamic movement±0.1 mm radial; ±0.2 mm axial
Operating speed≤6,000 min⁻¹; allow 3.3 K self-heating per 1,000 rpm when determining operating temperature range
Rotor moment of inertia40 gcm²
Bearing lifetime3.6 × 10¹⁰ revolutions
Angular acceleration≤500,000 rad/s²
IP ratingIP67 housing/cable side; IP65 shaft side according to IEC 60529
Relative humidity90%; condensation not permitted
Operating temperature−40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable
Storage temperature−40 to +100 °C without packaging
Shock resistance70 g, 6 ms; EN 60068-2-27
Vibration resistance30 g, 10–2,000 Hz; EN 60068-2-6
EMCEN 61000-6-2 and EN 61000-6-3
MTTFD300 years, EN ISO 13849-1; nominal component load, average ambient +40 °C, 8,760 h/year; all electronic failures counted as hazardous; standard product, not a safety component
Physical Weight (kg)0.2

Industrial Applications

1. Tracking feed travel through a coupled roller

A feed roller can drive the encoder through a mechanically compatible hollow-shaft connection. External counting logic converts incremental pulses to material travel using the installed roller circumference and actual transmission ratio. The 10,000-pulse configuration supplies the angular increment basis, while setup assesses roller slip, the controller counting mode and the documented electrical frequency and mechanical speed limits.

Problem Solved

Incremental rotation counts give external feed control a travel reference tied to the roller, helping coordinate material advance with a cutting or positioning sequence.

Feed travel 10,000 pulses/revolution Hollow shaft

2. Monitoring speed and direction of a rotating drive

A rotating drive can couple to the encoder and feed A and B signals to a compatible quadrature input. External motion logic determines speed from pulse timing and direction from channel phase order. The programmable TTL/HTL interface establishes the required electrical level, with the factory TTL setting and the 600 kHz output limit considered when configuring the receiving electronics.

Problem Solved

Quadrature pulse timing and phase order give external motion logic speed and direction information, helping compare actual drive movement with the commanded operating condition.

Speed feedback Direction TTL/HTL

3. Referencing a rotary process once per shaft revolution

A rotary process can use A/B counts for relative movement and the Z reference signal to identify a repeatable event within each shaft turn. External sequencing aligns its cycle counter to that event. The configured reference gating and programmable zero-pulse width establish the pulse behavior, while mechanical coupling and startup logic define how the process reference is acquired.

Problem Solved

A once-per-revolution reference event helps external sequencing relate incremental counts to the rotary process cycle, supporting repeatable phase tracking after the reference has been acquired.

Cycle reference Z signal Configurable pulse width
Select your currency