SICK 1078888 DFS60B-S4WA00050 50 PPR HTL 0-SET Encoder

USD 476.84

50-pulse incremental encoder with six HTL/push-pull channels, hardware 0-SET on pin 7, 10 ×19 mm solid shaft and radial M23 twelve-pin connector.

SKU SICK-1078888 Category
SICK Encoders

SICK DFS60B-S4WA00050 50 PPR HTL 0-SET Encoder

BrandSICK
Model IdentifierDFS60B-S4WA00050
Official Part Number1078888

Technical Overview

The SICK DFS60B-S4WA00050 is a 50-pulse-per-revolution incremental encoder with six HTL/push-pull channels and a hardware 0-SET input. A and B quadrature signals, the 90° electrical reference Z, and their inverted counterparts connect through a radial M23 twelve-pin male connector. Pin 7 assigns the current shaft position to Z when the documented input levels and timing are applied. The 10 mm solid shaft has a flat, 19 mm length and face-mount flange. Its HTL signal-output diagram specifies 10–32 V operation, with 30 ms initialization and output frequency up to 600 kHz. The stainless steel shaft and aluminum construction provide IP65 at the shaft and IP67 on the housing/connector side when mated.

50 PPR HTL/push-pull incremental encoder with hardware 0-SET, 10 ×19 mm solid shaft and radial M23 twelve-pin connector.

Key Features

  • 50 pulses per revolution; incremental rotary feedback
  • Six HTL/push-pull channels: A, B and Z with inverted counterparts
  • Hardware 0-SET input on M23 pin 7
  • 0-SET input HIGH 4 V to Us; LOW 0–3 V; specified reset timing
  • 10 ×19 mm solid shaft with flat; face-mount flange
  • Radial M23 twelve-pin male connector
  • 10–32 V HTL operation per output diagram; ≤0.7 W without load
  • 30 ms initialization; output frequency ≤600 kHz; load current ≤30 mA
  • 80 N radial and 40 N axial permissible shaft loading
  • IP67 housing/connector side when mated; IP65 shaft side; cable-dependent temperature limits

Assign the index to a chosen mechanical reference through hardware 0-SET while supplying 50-pulse HTL rotation feedback to external control.

Technical Specification Matrix

ParameterValue
Product typeIncremental rotary encoder
Pulses per revolution50; observe manufacturer maximum-revolution characteristic and output-frequency limit
Measuring step90° electrical / pulses per revolution
Measuring-step deviation±0.08° at non-binary number of lines
Error limits±0.05°
Electrical interfaceHTL / push-pull
Signal channelsSix: A, A inverted, B, B inverted, Z, Z inverted
Initialization time30 ms
Output frequency≤600 kHz
Load current≤30 mA
Power consumption≤0.7 W without load
Power supply10–32 V for HTL operation, as shown in manufacturer signal-output diagram
Reference signalOne; 90° electrical, logically gated with A and B
ConnectionRadial M23 twelve-pin male connector
M23 signal assignment1=B inverted; 3=Z; 4=Z inverted; 5=A; 6=A inverted; 8=B; 10=GND; 12=+Us; 2, 9 and 11 not connected
Screen connectionScreen connected to housing on encoder side and ground on control side
Reverse-polarity protectionProvided
Output short-circuit protectionAgainst another channel, Us or GND for maximum 30 s
Mechanical designSolid shaft with flat; face-mount flange
Shaft sizeØ10 mm f7 ×19 mm; axial length 19 ±0.3 mm in drawing
Pilot diameterØ36 mm f8
Flange mountingThree M4 threads, 6 mm deep; 120° spacing on Ø48 ±0.05 mm pitch circle
Shaft materialStainless steel
Flange materialAluminum
Housing materialAluminum die cast
Startup torque0.5 Ncm at +20 °C
Operating torque0.3 Ncm at +20 °C
Permissible shaft loading80 N radial; 40 N axial
Mechanical operating speed≤9,000 rpm; allow self-heating of 3.3 K per 1,000 rpm; usable speed also limited by pulse count and output frequency
Rotor moment of inertia6.2 gcm²
Bearing lifetime3.6 ×10¹⁰ revolutions
Angular acceleration≤500,000 rad/s²
IP ratingIP67 housing/connector side with mating connector fitted; IP65 shaft side, IEC 60529
Operating temperature, stationary cable−40 to +100 °C
Operating temperature, flexible cable−30 to +100 °C
Storage temperature−40 to +100 °C, without packaging
Relative humidity90%, condensation not permitted
Shock resistance70 g, 6 ms, EN 60068-2-27
Vibration resistance30 g, 10–2,000 Hz, EN 60068-2-6
EMCEN 61000-6-2 and EN 61000-6-3
MTTFD300 years to EN ISO 13849-1; nominal component load, average ambient 40 °C, 8,760 h/year; standard product, not a safety component
Hardware 0-SETProvided on M23 pin 7; H-active; LOW=0–3 V, HIGH=4 V to Us
0-SET timingApply Us for >250 ms after the input has been open or at GND for at least 1,000 ms; assigns Z to current shaft position
Physical Weight (kg)0.3

Industrial Applications

1. Tracking relative feed travel in a material-handling mechanism

A material-handling mechanism can couple the encoder to its feed drive and count A/B transitions in an external controller. Pulse count and direction provide a relative rotation reference that the controller converts to travel using calibrated machine geometry. The integration assesses receiver decoding, backlash, slip and output-frequency limits before using that reference to coordinate repeated material advances.

Problem Solved

Quadrature rotation feedback supplies external feed control with relative travel and direction information, helping coordinate material advances according to the calibrated mechanical drive arrangement.

Relative feed travel A/B quadrature External controller

2. Supplying rotational speed feedback from a driven roller

A driven roller can transfer motion through a suitable shaft coupling to the encoder’s solid shaft. An external counter derives rotational speed from pulses per revolution and elapsed time. The installation accounts for receiver input levels, shaft loading and alignment, with pulse-frequency limits and the specified self-heating allowance assessed across the intended operating speed and temperature range.

Problem Solved

A shaft-referenced pulse stream gives external speed control a rotational feedback value, helping regulate roller movement using the coupled encoder as the motion reference.

Roller-speed feedback Incremental pulses Shaft coupling

3. Assigning the index at a commissioned mechanical reference

During machine commissioning, the mechanism can hold the encoder shaft at its intended reference position and apply the documented hardware 0-SET sequence to M23 pin 7. The input must first remain open or at GND for at least 1,000 ms, followed by Us for longer than 250 ms. External sequencing then relates the recurring Z index to that selected mechanical position.

Problem Solved

Hardware index assignment gives external sequencing a reference tied to the commissioned shaft position, helping align incremental counts with the intended mechanical cycle without moving the encoder coupling.

Hardware 0-SET M23 pin 7 Commissioned reference