| Functional principle | Incremental rotary encoder |
| Pulses per revolution | 1,024 |
| Measuring step | 90 electrical degrees / pulses per revolution |
| Measuring step deviation | ±0.15° at binary number of lines |
| Error limits | ±0.3° |
| Output interface | HTL / push-pull; fixed electrical interface |
| Signal channels | Six: A, A complement, B, B complement, Z, Z complement |
| Initialization time | 40 ms |
| Output frequency | ≤300 kHz |
| Load current | ≤30 mA |
| Power consumption | ≤0.5 W without load |
| Power supply | 10–32 V |
| Reference signal | One per revolution; 90 electrical degrees; logically gated with A and B |
| Connection | 1.5 m eight-wire universal cable; radial or axial routing without bends at exit |
| Cable conductor functions | WH=A; BN=A complement; PK=B; BK=B complement; VT=Z; YE=Z complement; BU=GND; RD=+Us |
| Screen connection | Screen connected to housing on encoder side; connected to ground on control side |
| Reverse polarity protection | Yes |
| Output short-circuit protection | Against another channel, Us or GND, maximum 30 s |
| Mechanical design | Through hollow shaft with front clamp |
| Shaft diameter | 12 mm; bore tolerance F7; customer shaft tolerance j7 |
| Minimum customer shaft engagement | 15 mm |
| Shaft material | Stainless steel |
| Flange material | Aluminum |
| Housing material | Aluminum die cast |
| Startup torque | 0.8 Ncm at +20 °C |
| Operating torque | 0.6 Ncm at +20 °C |
| Permissible static movement | ±0.3 mm radial; ±0.5 mm axial |
| Permissible dynamic movement | ±0.1 mm radial; ±0.2 mm axial |
| Operating speed | ≤6,000 rpm |
| Speed-related self-heating | Allow 3.3 K per 1,000 rpm when designing the operating temperature range |
| Rotor moment of inertia | 40 gcm² |
| Bearing lifetime | 3.6 × 10^10 revolutions |
| Angular acceleration | ≤500,000 rad/s² |
| Cable diameter | 5.6 ±0.2 mm |
| Cable bend radius | 30 mm |
| IP rating | IP65 housing side and cable connection; IP65 shaft side; IEC 60529 |
| Permissible relative humidity | 90%; condensation not permitted |
| Operating temperature | 0 to +85 °C |
| Storage temperature | −40 to +100 °C, without package |
| Shock resistance | 50 g, 6 ms; EN 60068-2-27 |
| Vibration resistance | 20 g, 10–2,000 Hz; EN 60068-2-6 |
| EMC | EN 61000-6-2 and EN 61000-6-4 |
| MTTFD | 300 years, EN ISO 13849-1; standard product, not a safety component; nominal component load, average ambient 40 °C, 8,760 h/year |
| Physical Weight (kg) | 0.2 |