SICK 1037419 DFS60E-TEEK01024 HTL Incremental Encoder

USD 428.74

DFS60E-TEEK01024 offers 1,024 pulses/rev, six HTL push-pull channels, 10–32 V supply, a 12 mm through hollow shaft, 1.5 m cable and IP65 protection.

SKU SICK-1037419 Category
SICK Encoders

SICK DFS60E-TEEK01024 HTL Incremental Encoder

BrandSICK
Model IdentifierDFS60E-TEEK01024
Official Part Number1037419

Technical Overview

The SICK DFS60E-TEEK01024 is an incremental rotary encoder with 1,024 pulses per revolution and six fixed HTL push-pull signal channels. A 12 mm through hollow shaft with front clamp fits a suitable customer shaft, with at least 15 mm engagement specified in the drawing. Channels A and B and their complements support external counting and direction evaluation, while one Z reference is 90 electrical degrees wide and gated with A and B. The 1.5 m eight-wire universal cable permits radial or axial routing without an exit bend. Supply is 10–32 V and output frequency is limited to 300 kHz. The aluminum die-cast housing provides IP65 protection, with operation from 0 to +85 °C.

1,024-pulse/revolution HTL push-pull incremental encoder with 12 mm through hollow shaft, front clamp, 10–32 V supply and 1.5 m universal cable.

Key Features

  • 1,024 pulses per revolution; fixed HTL push-pull interface
  • Six channels: A, B and Z with their complements
  • One 90° electrical Z reference, logically gated with A and B
  • 12 mm through hollow shaft with front clamp; minimum 15 mm shaft engagement
  • 10–32 V supply; no-load power consumption ≤0.5 W
  • 40 ms initialization; output frequency ≤300 kHz; load current ≤30 mA
  • 1.5 m eight-wire universal cable, routable radially or axially without an exit bend
  • Operating speed ≤6,000 rpm; account for 3.3 K self-heating per 1,000 rpm
  • Stainless steel shaft, aluminum flange and aluminum die-cast housing
  • IP65 housing/cable and shaft sides; 0 to +85 °C operation

Provide 1,024 pulses per revolution through HTL push-pull channels using a through hollow shaft for direct rotational feedback to external control.

Technical Specification Matrix

ParameterValue
Functional principleIncremental rotary encoder
Pulses per revolution1,024
Measuring step90 electrical degrees / pulses per revolution
Measuring step deviation±0.15° at binary number of lines
Error limits±0.3°
Output interfaceHTL / push-pull; fixed electrical interface
Signal channelsSix: A, A complement, B, B complement, Z, Z complement
Initialization time40 ms
Output frequency≤300 kHz
Load current≤30 mA
Power consumption≤0.5 W without load
Power supply10–32 V
Reference signalOne per revolution; 90 electrical degrees; logically gated with A and B
Connection1.5 m eight-wire universal cable; radial or axial routing without bends at exit
Cable conductor functionsWH=A; BN=A complement; PK=B; BK=B complement; VT=Z; YE=Z complement; BU=GND; RD=+Us
Screen connectionScreen connected to housing on encoder side; connected to ground on control side
Reverse polarity protectionYes
Output short-circuit protectionAgainst another channel, Us or GND, maximum 30 s
Mechanical designThrough hollow shaft with front clamp
Shaft diameter12 mm; bore tolerance F7; customer shaft tolerance j7
Minimum customer shaft engagement15 mm
Shaft materialStainless steel
Flange materialAluminum
Housing materialAluminum die cast
Startup torque0.8 Ncm at +20 °C
Operating torque0.6 Ncm at +20 °C
Permissible static movement±0.3 mm radial; ±0.5 mm axial
Permissible dynamic movement±0.1 mm radial; ±0.2 mm axial
Operating speed≤6,000 rpm
Speed-related self-heatingAllow 3.3 K per 1,000 rpm when designing the operating temperature range
Rotor moment of inertia40 gcm²
Bearing lifetime3.6 × 10^10 revolutions
Angular acceleration≤500,000 rad/s²
Cable diameter5.6 ±0.2 mm
Cable bend radius30 mm
IP ratingIP65 housing side and cable connection; IP65 shaft side; IEC 60529
Permissible relative humidity90%; condensation not permitted
Operating temperature0 to +85 °C
Storage temperature−40 to +100 °C, without package
Shock resistance50 g, 6 ms; EN 60068-2-27
Vibration resistance20 g, 10–2,000 Hz; EN 60068-2-6
EMCEN 61000-6-2 and EN 61000-6-4
MTTFD300 years, EN ISO 13849-1; standard product, not a safety component; nominal component load, average ambient 40 °C, 8,760 h/year
Physical Weight (kg)0.2

Industrial Applications

1. Tracking a material-feed roller

A material feeder can mount the 12 mm through hollow shaft on a suitable roller shaft and secure it with the front clamp. An external counter accumulates the 1,024 pulses per revolution and converts rotation to feed travel using the installed roller circumference. Commissioning accounts for slip, transmission geometry, shaft engagement and receiving-counter limits so the pulse count represents the actual machine movement.

Problem Solved

A pulse count tied to roller rotation gives external feed-control logic a travel reference, supporting material advancement between operations when the mechanical transmission is characterized.

Roller travel 1,024 pulses/rev Through hollow shaft

2. Monitoring speed and direction on a machine shaft

A machine drive can connect the A and B signals to a compatible HTL input counter and evaluate their phase order and pulse timing. External monitoring logic derives shaft direction and speed from those signals. Setup keeps operation within the 6,000 rpm mechanical limit and 300 kHz output limit, while accounting for self-heating and the receiving counter bandwidth at the chosen operating speed.

Problem Solved

Phase-related A and B signals let external monitoring logic distinguish forward from reverse movement and track speed changes, providing a rotational reference for machine operating checks.

HTL input counter Speed and direction A/B phase

3. Referencing a repeated rotary cycle

A rotating handling mechanism can use the single Z reference as a once-per-revolution event for external sequencing logic. The signal is 90 electrical degrees wide and logically gated with A and B, allowing the controller to relate it to counted rotation. The machine establishes its reference after startup rather than assuming that the incremental signal retains an absolute position during a power interruption.

Problem Solved

A repeated shaft-index event gives external sequencing logic a consistent rotational reference, helping align periodic handling actions with counted movement during each machine cycle.

One Z reference 90° electrical External sequencing