1. Confirming a clamp target beside a coolant-exposed fixture
A machining fixture can present a metal clamp target to the non-flush sensing face at a controlled seated gap. Coolant-lubricant resistance and V2A/LCP construction support the sensing location near the process. External sequencing logic reads the NPN normally-open state after the clamp settles, while installation accounts for the stated clearances, assured range and actual target-material reduction factor.
Problem Solved
A coolant-resistant inductive reference helps external sequencing logic recognize the intended metal clamp position, supporting process coordination at a fixture location exposed to machining fluids.
Coolant zone
Clamp position
NPN output
2. Counting separated metal features on a fast-moving carrier
A carrier can present spaced metal features to the sensor and send NPN transitions to external counting electronics. The 4,000 Hz switching rating provides the stated frequency basis, while the 4 mm nominal range defines the reference sensing distance. Commissioning validates actual material reduction, target coverage, separation and non-flush mounting clearances so that each feature generates a distinct event.
Problem Solved
Repeated inductive transitions provide external counting logic with feature-passage events, helping track metal carriers or parts without relying on surface color or an optical path.
Metal-feature counter
4,000 Hz
Non-flush M8
3. Checking installation margin during sensor maintenance
A maintenance technician can use the visual adjustment indicator while moving a known metal reference target through the installed sensing position. The manufacturer relates the indication to Sr and the assured sensing limit, giving a local setup aid. The 3.24 mm assured range and material reduction factors support assessing the working gap before external machine logic resumes normal operation.
Problem Solved
The local adjustment aid gives maintenance a visible reference when restoring the sensing position, helping avoid a marginal gap after a sensor or target bracket has moved.
Visual adjustment aid
Installation margin
Assured range