Skip to content

Contact Us:
sales@inosaki.com

SICK 1040981 IME18-12NPSZC0K PNP Inductive Sensor

SICK 1040981 IME18-12NPSZC0K PNP Inductive Sensor

USD 28.60

IME18-12NPSZC0K offers 12 mm nominal inductive sensing, PNP normally-open output, 1,000 Hz switching, non-flush M18 mounting, a short body and M12 connection.

SKU: SICK-1040981 Category:
SICK IME

SICK IME18-12NPSZC0K PNP Inductive Sensor

BrandSICK
Model IdentifierIME18-12NPSZC0K
Official Part Number1040981

Technical Overview

The SICK IME18-12NPSZC0K is an M18 × 1 inductive proximity sensor with a PNP normally-open output and DC three-wire operation. Its nominal sensing range is 12 mm and assured range is 9.72 mm, with separate reduction factors for different target metals. The short-body sensor uses non-flush installation and a four-pin M12 male connector; its integral connector is included in the 50 mm axial extent. The 10–30 V DC device provides 1,000 Hz switching, with output current up to 200 mA and no-load current no greater than 10 mA. The nickel-plated brass housing and PA 66 sensing face provide IP67 protection and −25 to +75 °C operation; two mounting nuts are supplied.

M18 PNP normally-open inductive sensor with 12 mm nominal range, 9.72 mm assured range, 1,000 Hz switching and M12 four-pin connection.

Key Features

  • M18 × 1 inductive proximity sensor; short body
  • 12 mm nominal range Sn; 9.72 mm assured range Sa
  • Non-flush
  • PNP normally-open output; DC three-wire; 1,000 Hz switching
  • 10–30 V DC; ≤200 mA continuous output; ≤10 mA no-load current
  • M12 four-pin male connector
  • ≤100 ms delay before availability; 5–15% hysteresis
  • Nickel-plated brass housing; PA 66 sensing face
  • Two nickel-plated brass mounting nuts, 24 mm across flats
  • IP67; −25 to +75 °C operation

Detect a metal target at a non-flush M18 sensing position and send a PNP normally-open condition to external machine control.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing
Housing designMetric M18 short body
Mounting threadM18 × 1
InstallationNon-flush
Nominal sensing range Sn12 mm
Assured sensing range Sa9.72 mm
Switching outputPNP normally open, NO
Electrical wiringDC three-wire
Switching frequency1,000 Hz
Power supply10–30 V DC
Ripple≤10%
Voltage drop≤2 V at maximum output current
Continuous output current≤200 mA
No-load current≤10 mA
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
ProtectionShort-circuit and power-up pulse protection
ConnectionM12 four-pin male connector
Pin assignmentCD-007: 1 BN=L+; 4 BK=NO; 2=not connected; 3 BU=M
Housing materialNickel-plated brass
Sensing face materialPA 66 plastic
Axial extent50 mm including integral M12 connector, manufacturer drawing
Thread length23 mm
Tightening torque≤40 Nm
Items suppliedTwo nickel-plated brass mounting nuts; 24 mm across flats
IP ratingIP67 to EN 60529
Operating temperature−25 to +75 °C
EMCEN 60947-5-2
MTTFD1,735 years
DCavg0%
UL fileNRKH.E181493
Material reduction factorsReference values may vary: St37 steel 1; V2A/304 stainless approximately .8; aluminum approximately .45; copper approximately .4; brass approximately .4
Installation clearancesManufacturer diagram labels A/B/C/D/E/F = 18 / 36 / 18 / 36 / 24 / 96 mm; use with non-flush installation diagram
Delay before availability≤100 ms
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
Local indicationLED shown in body drawing

Industrial Applications

1. Confirming a metal fixture element is seated

An assembly fixture can present a metal locating element to the sensing face at a repeatable seated gap. The PNP normally-open output gives external sequence logic a discrete position condition after the mechanism settles. Commissioning uses the nominal and assured ranges, actual metal reduction factor and documented non-flush mounting clearances to establish the detection arrangement.

Problem Solved

A contactless metal-position reference helps external sequencing logic recognize a seated fixture element, supporting coordination of the following operation with the mechanism in its expected position.

Fixture position PNP normally open Inductive sensing

2. Counting metal features passing a guide

A guide can move separated metal tabs past the fixed sensing face and route PNP transitions to an external counter. The 1,000 Hz switching rating provides the sensor timing basis. Setup checks actual tab material, target coverage, gap and separation against the documented sensing range and reduction factors so successive metal features produce distinct count events.

Problem Solved

Metal-passage transitions give external counting logic discrete feature events, helping track feed movement without depending on optical surface color or an added magnetic target.

Metal tab counting 1,000 Hz PNP transitions

3. Finding a mechanism that remains at a monitored stop

A transfer mechanism can carry a metal flag that reaches the sensor at a fixed stop. External control observes the PNP condition and compares its duration with the expected release sequence. Non-flush installation and the metal-specific sensing ranges establish the monitored position; the controller supplies the dwell timer and decides whether the mechanism has failed to clear.

Problem Solved

A sustained metal-target condition gives external process logic a reference for recognizing an occupied stop, helping identify a mechanism that has not departed during its expected release interval.

Stop occupancy External dwell timing Metal flag