SICK 6042145 PBT-RB040SG1SSFALA0Z 0–40 bar Pressure Transmitter

SICK 6042145 PBT-RB040SG1SSFALA0Z 0–40 bar Pressure Transmitter

USD 195.00

PBT-RB040SG1SSFALA0Z measures 0–40 bar gauge pressure with a two-wire 4–20 mA output, G ¼ A process connection, 316L wetted parts and DIN A L-connector.

SKU: SICK-6042145 Category:
SICK PBT

SICK PBT-RB040SG1SSFALA0Z 0–40 bar Pressure Transmitter

BrandSICK
Model IdentifierPBT-RB040SG1SSFALA0Z
Official Part Number6042145

Technical Overview

The SICK PBT-RB040SG1SSFALA0Z is a pressure transmitter for liquid and gaseous media, measuring gauge pressure from 0 to 40 bar. Its two-wire 4–20 mA signal provides a pressure reference to external analog measurement or control equipment, with supply from 8–30 V DC and a supply-dependent load limit. The G ¼ A process connection and measuring chamber use 316L stainless steel, while the housing is stainless steel and the seal is FKM. Accuracy is within ±1% of span, including non-linearity, hysteresis, zero-point and full-scale error under the stated reference conditions. Response is below 4 ms, and both process and operating ambient temperatures span 0 to +80 °C. A DIN EN 175301-803 A L-connector provides electrical connection.

0–40 bar gauge pressure transmitter with two-wire 4–20 mA output, G ¼ A process connection, 316L wetted parts, FKM seal and DIN A L-connector.

Key Features

  • 0–40 bar gauge pressure measurement for liquid and gaseous media
  • Two-wire 4–20 mA analog output; 8–30 V DC supply
  • Load limit RA ≤(L+ −8 V)/0.02 A for the selected current output
  • Accuracy ≤±1% of span; BFSL non-linearity ≤±0.5%
  • Response <4 ms; non-repeatability ≤0.1% of span
  • G ¼ A process connection, specified to ISO 1179-2
  • 316L process connection and measuring chamber; stainless steel housing; FKM seal
  • DIN EN 175301-803 A L-connector; IP65 with an appropriately rated mating connector
  • 0 to +80 °C process, rated and operating ambient temperature ranges
  • Minimum 100 million load cycles; one-year stability ≤0.1% of span

Convert 0–40 bar gauge pressure into a two-wire 4–20 mA signal for external process monitoring and control using 316L wetted components.

Technical Specification Matrix

ParameterValue
Functional principleGauge pressure transmitter
MediumLiquid and gaseous media
Measuring range0–40 bar gauge
Output signal4–20 mA, two-wire
Maximum ohmic loadRA ≤(L+ −8 V)/0.02 A, in ohms, for the selected two-wire 4–20 mA output
Power supply8–30 V DC
Supply requirementsLimited energy circuit to section 9.3 of UL/EN/IEC 61010-1, LPS to UL/EN/IEC 60950-1, or Class 2 to UL 1310/UL 1585; power supply suitable for operation above 2,000 m when used above that altitude
Power consumptionSignal current, maximum 25 mA, for current output
Communication interfaceNo digital communication interface specified
Process connectionG ¼ A; ISO 1179-2; drawing also identifies G ¼ A DIN 3852-E
Pressure portStandard
Pressure peak dampingIntegrated port for G ¼ to DIN 3852-E: 0.3 mm at and above 10 bar
Wetted parts316L stainless steel process connection and measuring chamber
Housing materialStainless steel
SealFKM
ConnectionL-connector, DIN EN 175301-803 A
Two-wire L-connector assignmentTerminal 1=L+/QA; terminal 2=M; terminal 3 not used in the two-wire drawing
Overvoltage protection36 V DC for the selected 4–20 mA output
Short-circuit protectionQA towards M
Reverse polarity protectionL+ to M
Protection classIII
Isolation voltage500 V DC
IP ratingIP65 to IEC 60529 when connected with a mating female connector providing the corresponding rating
Accuracy≤±1% of span, including non-linearity, hysteresis, zero-point and full-scale error; measurement error to IEC 61298-2
Non-linearity≤±0.5%; best fit straight line (BFSL), IEC 61298-2
Zero-signal adjustment accuracyTypical ≤0.5% of span; maximum ≤0.8% of span, with 0.5% non-linearity
Hysteresis≤0.16% of span
Non-repeatability≤0.1% of span
Response time<4 ms
Signal noise≤0.3% of span
One-year stability≤0.1% of span to IEC 61298-2
Rated temperature range0 to +80 °C
Process temperature0 to +80 °C
Operating temperature0 to +80 °C
Storage temperature−40 to +70 °C
Temperature errorTypical ≤±1.0% of range; maximum ≤±2.5% of range
Reference conditionsIEC 61298-1
Service lifeMinimum 100 million load cycles
Relative humidity45–75%
Shock resistance500 g; IEC 60068-2-27
Vibration resistance10 g, under resonance, IEC 60068-2-6; 20 g only optional
MTTF815 years
Process-thread length14 mm in the G ¼ A drawing
Wrench size27 mm across flats

Industrial Applications

1. Regulating a pressurized liquid supply

A pump-fed liquid line can connect the transmitter to a compatible G ¼ A port and send its 4–20 mA signal to an external analog controller. The controller compares measured gauge pressure with its configured reference and adjusts a separate pump or valve. Setup keeps normal pressure within 0–40 bar and verifies fluid compatibility, the 0 to +80 °C process range and the supply-dependent loop load.

Problem Solved

A continuous gauge-pressure signal gives external regulation logic a process reference, helping maintain the configured supply condition as demand changes through the liquid distribution line.

Liquid supply 0–40 bar gauge 4–20 mA

2. Measuring pressure decay in an isolated test fixture

An isolated test fixture can measure pressure before and after a controlled hold period using the two-wire analog output. External test software calculates the change and compares it with fixture-specific acceptance limits after stabilization. The response below 4 ms supports acquisition timing, while accuracy, non-repeatability, signal noise and temperature effects define whether the expected decay is distinguishable for the actual test.

Problem Solved

A pressure trace during the isolated hold gives external test logic evidence of pressure loss, supporting a fixture-specific decay assessment with thresholds matched to the documented measurement limits.

Isolated hold test Analog pressure trace <4 ms response

3. Recording pressure cycles for machine maintenance

A machine logger can sample the pressure signal during repeated pressurization and release cycles and associate each trace with its operating phase. The 0–40 bar gauge range and continuous current output provide the measurement basis, while the stated minimum 100 million load cycles supports repeated pressure cycling. External analysis compares timing and pressure profiles with a recorded reference while accounting for temperature and long-term stability.

Problem Solved

Recorded pressure-cycle profiles help maintenance personnel identify changes in machine behavior, using measured pressure and timing trends to direct inspection of separate valves, seals or supply equipment.

Cycle logging Pressure profiles External maintenance analysis