Skip to content

Contact Us:
sales@inosaki.com

SICK 1062540 RE13-SA64 Magnetic Safety Switch with Actuator

SICK 1062540 RE13-SA64 Magnetic Safety Switch with Actuator

USD 87.62

RE13-SA64 provides two N/O reed contacts, 7 mm assured switch-on distance, 20 mm assured switch-off distance and a 0.2 m lead with M12 four-pin plug.

SKU: SICK-1062540 Category:
SICK Safety Switches

SICK RE13-SA64 Magnetic Safety Switch with Actuator

BrandSICK
Model IdentifierRE13-SA64
Official Part Number1062540

Technical Overview

The SICK RE13-SA64 is a magnetic non-contact safety switch supplied with an actuator. It has two normally-open reed contacts, one active sensor surface and five actuation directions, with 7 mm assured switch-on and 20 mm assured switch-off distances. The Type 4 interlocking device has a low actuator coding level under EN ISO 14119. A 0.2 m PVC lead terminates in an M12 four-pin plug; contacts are rated up to 30 V DC and 100 mA. The VISTAL housing provides IP67 protection and −30 to +60 °C operation. The switch has no internal fault detection and cannot assume a safe state on a fault; connected safety-related logic performs fault detection. Safe series connection with diagnostics is supported through Flexi Loop.

Magnetic safety switch with actuator, two N/O reed contacts, 7 mm assured switch-on distance, 20 mm assured release distance and M12 pigtail connection.

Key Features

  • Magnetic sensor supplied with actuator; two N/O reed contacts
  • No N/C or separate signaling contacts
  • 7 mm assured switch-on distance; 20 mm assured switch-off distance
  • One active sensor surface; five actuation directions
  • Type 4 interlocking device, low actuator coding level, EN ISO 14119
  • B10d: 20 million switching cycles with small load
  • Fault detection and fault response require connected safety-related logic
  • Safe series connection with diagnostics through Flexi Loop
  • 0.2 m PVC cable with four-pin M12 plug; contacts ≤30 V DC and ≤100 mA
  • VISTAL housing; IP67; −30 to +60 °C operating and storage range

Provide two contact paths for actuator-position monitoring, with external safety-related logic handling fault detection and Flexi Loop available for diagnosed series connection.

Technical Specification Matrix

ParameterValue
Product configurationMagnetic non-contact safety switch with actuator
Sensor principleMagnetic
Safety contactsTwo N/O reed contacts; zero N/C contacts
Signaling contactsNone
Assured switch-on distance Sao7 mm
Assured switch-off distance Sar20 mm
Active sensor surfacesOne
Actuation directionsFive
Interlocking-device typeType 4, EN ISO 14119
Actuator coding levelLow, EN ISO 14119
B10d2 × 10⁷ switching cycles with small load
Fault detectionNo internal fault detection; switch cannot assume a safe state in the event of a fault; fault detection performed by the connected safety-related logic unit
Safe series connectionWith Flexi Loop, including diagnostics
Connection0.2 m cable with M12 four-pin plug
Cable diameter5.8 mm
Conductor cross-section0.25 mm²
Cable materialPVC; copper conductors
Coupling nut materialNickel-plated brass
Bending radiusFixed installation >12 × cable diameter; moving cable >15 × cable diameter
Contact pin assignmentN/O contact 1: pins 1 BN–2 WH; N/O contact 2: pins 3 BU–4 BK
Contact sequenceManufacturer timing diagram shows the two input contact sequences to be monitored by connected logic; no numeric monitoring time specified
Switching voltage≤30 V DC
Switching current≤100 mA
Housing designRectangular
Housing materialVISTAL
Mounting holesØ4.5 mm; Ø8.5 mm counterbore; 22 mm spacing shown in sensor drawing
IP ratingIP67, IEC 60529
Operating temperature−30 to +60 °C
Storage temperature−30 to +60 °C
Vibration resistance10–55 Hz, 1 mm, EN 60947-5-3
Shock resistance30 g, 11 ms, EN 60947-5-3

Industrial Applications

1. Monitoring opening of an access guard

An access guard can carry the matching actuator so that opening the guard moves it away from the fixed magnetic sensor. The two N/O contacts provide separate paths to suitable safety-related logic, using the 7 mm assured switch-on and 20 mm assured switch-off distances during installation assessment. The connected logic performs fault detection and controls the machine’s protective response; the switch cannot provide that response independently.

Problem Solved

Two contact paths give connected safety-related logic a guard-position input, helping the complete interlocking system respond when the actuator leaves the intended closed-guard region.

Guard opening Two N/O contacts External safety logic

2. Checking contact sequence in an interlock circuit

An interlocking circuit can connect the two reed contact paths individually to compatible safety-related logic. During actuator approach and withdrawal, the external logic evaluates both states and their expected sequence using the manufacturer timing diagram. Fault recognition and the machine response belong to that external unit, because the sensor has no internal fault detection and cannot assume a safe state on a fault.

Problem Solved

Separate contact-state information gives connected safety-related logic a basis for monitoring inconsistent interlock behavior, helping the complete system distinguish expected actuator movement from a detected contact-sequence fault.

Contact monitoring Switching sequence External fault detection

3. Connecting several guarded access points with diagnostics

A machine with several guarded access points can integrate compatible RE13-SA64 switches using the documented Flexi Loop arrangement for safe series connection with diagnostics. Each point supplies its actuator-position contact information to that system. External safety-related logic evaluates the protective function and fault response, while Flexi Loop diagnostics provide the documented diagnostic connection capability for the distributed access points.

Problem Solved

Diagnosed series connection gives a compatible Flexi Loop system guard-contact information with diagnostic access, helping external control investigate an access-point condition within the complete safeguarding arrangement.

Multiple access points Flexi Loop Series diagnostics
Select your currency