SICK 1051884 S32B-2011EA Remote EFI Safety Laser Scanner

USD 2,960.10

S32B-2011EA offers a 2 m protective field, 16 triple field sets, 32 monitoring cases and M12 seven-pin connection for integration in an EFI safety system.

SKU SICK-1051884 Category
SICK S300 Mini

SICK S32B-2011EA S300 Mini Remote EFI Safety Laser Scanner

BrandSICK
Model IdentifierS32B-2011EA
Official Part Number1051884

Technical Overview

The SICK S32B-2011EA is an S300 Mini Remote safety laser scanner for integration into an indoor EFI safety system. It provides a 2 m protective field range with 270° scanning, 16 triple field sets, 48 fields and 32 monitoring cases. Static and dynamic protective-field switching support configured changes through EFI, while the connected EFI device determines the output arrangement. The Remote variant requires that system connection and has no local OSSD pair or universal I/Os. Resolution is configurable at 30, 40, 50 or 70 mm, and response depends on basic response and multiple sampling. PC-based CDS configuration uses RS-232; the IP65 unit connects through a 250 mm cable with an M12 seven-pin male connector.

Indoor EFI-system S300 Mini Remote safety laser scanner with 2 m protective field, 16 triple field sets, 32 monitoring cases and M12 seven-pin connection.

Key Features

  • 2 m protective field range; 270° scanning angle
  • 16 triple field sets; 48 fields; 32 monitoring cases
  • EFI system integration with configured external safety outputs
  • Static and dynamic protective-field switching via EFI
  • 30, 40, 50 or 70 mm configurable resolution; 0.5° angular resolution
  • Type 3 to IEC 61496; SIL 2; Category 3 and PL d
  • 80 ms stated response; configuration-dependent multiple sampling of 2–16
  • PC configuration with CDS; RS-232 at 38.4 kBaud; EFI ≤500 kBaud
  • 250 mm cable with M12 seven-pin male connector; 24 V DC nominal
  • 905 nm Class 1 laser; IP65 aluminum housing; −10 to +50 °C indoor operation

Select configured protective fields through EFI and integrate their intrusion conditions with the connected safety device for changing machine or vehicle operating cases.

Technical Specification Matrix

ParameterValue
Functional principleSafety laser scanner; electro-sensitive protective device
Product versionS300 Mini Remote
ApplicationIndoor industrial use
Protective field range2 m
Warning field range8 m at 15% reflectivity; warning fields are not for protecting people
Distance measuring range30 m; measured data output not available
Field configuration16 triple field sets; 48 fields; 32 monitoring cases
Scanning angle270°
Configurable resolution30, 40, 50 or 70 mm
Angular resolution0.5°
Response time80 ms; depends on basic response time and multiple sampling
Protective-field supplement100 mm
Multiple sampling2–16, configurable
Automatic reset delay2–60 s, configurable
ESPE typeType 3 to IEC 61496
Safety integrity levelSIL 2 to IEC 61508
Safety categoryCategory 3 to EN ISO 13849
Performance levelPL d to EN ISO 13849
PFHD8.0 × 10⁻⁸ per hour
Mission time20 years to EN ISO 13849
Contour as a referenceYes
Measured data outputNone
ConfigurationPC with CDS (Configuration and Diagnostic Software)
Configuration/diagnostics interfaceRS-232; 38.4 kBaud
Connection250 mm cable with M12 seven-pin male connector
Power supply24 V DC nominal; 16.8–30 V DC range
Supply current0.2 A at 24 V DC without output load; 0.22 A including maximum output load
Protection classIII to EN 50178 and EN 60950
Housing materialDie-cast aluminum
Housing colorRAL 1021 yellow; RAL 9005 black
Optics coverPolycarbonate with outside scratch-resistant coating
Mounting threadM5 × 7.5 mm
IP ratingIP65 to EN 60529
Operating temperature−10 to +50 °C
Storage temperature−25 to +50 °C
Vibration resistanceIEC 60068-2-6; IEC 60068-2-64; IEC 60721-3-5; IEC TR 60721-4-5; IEC 61496-3; Class 5M1 to IEC 60721-3-5
Shock resistanceIEC 60068-2-27; IEC 60721-3-5; IEC TR 60721-4-5; IEC 61496-3; Class 5M1 to IEC 60721-3-5
Continuous shock50 m/s² for 11 ms; 100 m/s² for 16 ms
Light sourcePulsed laser diode
Wavelength905 nm
Laser classClass 1 to 21 CFR 1040.10/1040.11 and IEC 60825-1
Detectable remission factor1.8% to >1,000%, reflectors
System integrationEFI system network required; e.g. Flexi Soft safety controller or another S300/S3000 safety laser scanner
Safe communication interfaceEFI; ≤500 kBaud
EFI extension cable limit≤20 m; only preassembled extension cables permitted
Protective-field switchingMonitoring-case switching; static and dynamic protective-field switching
Inputs via EFIFive static control inputs; one standby input; EFI system use required
OutputsDepend on configuration of the connected EFI device
Local safety outputsNo local OSSD pair; output evaluation through connected EFI system

Industrial Applications

1. Changing an indoor machine area with its operating case

An indoor machine with changing work zones can use the Remote scanner as part of an EFI safety system and select the corresponding configured monitoring case before each hazardous movement. The 16 triple field sets and 32 monitoring cases support process-dependent area selection. The connected safety device evaluates field conditions and provides the output arrangement; switching timing includes communication, configured sampling and the complete machine stopping behavior.

Problem Solved

Configured field selection links the monitored area to the machine operating case, helping the connected safety system issue stop demands for intrusion into the relevant work zone.

Process-dependent area 32 monitoring cases EFI system

2. Monitoring an access opening in an EFI machine system

A guarded indoor enclosure can place this 2 m-range Remote scanner vertically across an access opening and connect it to the machine EFI safety system. Whole-body passage through the protective plane changes the field condition evaluated by the connected device. Contour-as-reference monitoring supports the configured opening boundary, while the protection design accounts for persons standing beyond the scan plane and the complete system response.

Problem Solved

An access-plane intrusion supplies the connected EFI safety device with an entry condition, helping initiate the machine stop function through the configured external outputs.

Access protection Contour reference External outputs

3. Selecting vehicle fields for different travel conditions

An indoor guided vehicle can use EFI monitoring-case selection to choose configured protective and warning fields for different travel conditions. The Remote scanner supplies 16 triple field sets and 32 monitoring cases within its 2 m protective range. External vehicle safety control supplies the case information and output functions; field selection occurs early enough to include system communication, sampling and the vehicle stopping distance.

Problem Solved

Operating-case selection lets the vehicle safety system use the appropriate configured field for the travel condition, supporting preliminary warning and protective stop demands through separate field evaluations.

Vehicle field selection 16 field sets EFI communication
Select your currency